Users Guide
• Processors
• Remote Access
• Removable Flash Media
• Slots
• Temperatures
• Voltages
NOTE: The Power Supplies option is not available in PowerEdge 1900. Power Supply Monitoring and Power Monitoring features
are available only for systems that have two or more redundant, hot-swappable power supplies installed. These features are
unavailable for permanently installed, non-redundant power supplies that lack power management circuitry.
Main system chassis or main system properties
The system/server module may contain one main system chassis or several chassis. The main system chassis/main system contains the
essential components of a system. The Main System Chassis/Main System object action window includes the following:
Properties
Subtabs: Health | Information | System Components (FRU) | Front Panel
Under the Properties tab, you can:
• View the health or status of hardware components and sensors. Each listed component has a System/Server Module Component
Status Indicators icon next to its name. indicates that a component is healthy (normal). indicates that a component has a
warning (noncritical) condition and requires prompt attention. indicates that a component has a failure (critical) condition and
requires immediate attention.
indicates that a component's health status is unknown. The available monitored components include:
– Batteries
– Fans
– Hardware Log
– Intrusion
– Network
– Power Management
– Power Supplies
– Processors
– Temperatures
– Voltages
NOTE
: Batteries are supported only on the 10th generation PowerEdge systems. The Power supplies are not available on the
PowerEdge 1900. Power Management is supported on limited 10th generation PowerEdge systems. Power Supply Monitoring
and Power Monitoring features are available only for systems that have two or more redundant, hot-swappable powers supplies
installed. These features are unavailable for permanently installed, nonredundant power supplies that lack power management
circuitry.
NOTE: If the QLogic QLE2460 4Gb Single-Port Fibre Channel HBA, QLogic QLE2462 4Gb Dual-Port Fibre Channel HBA, Qlogic
QLE2562 Dual Port FC8 Adapter, or Qlogic QLE2560 Single Port FC8 Adapter cards are installed on the 12th generation
PowerEdge systems, the System Components (FRU) screen is not displayed.
• View information about the main system chassis attributes such as the host name, iDRAC version, Lifecycle Controller version, Chassis
Model, Chassis Lock, Chassis Service Tag, Express Service Code, and Chassis Asset Tag. The Express Service Code (ESC) attribute is
an 11-digit numeric-only conversion of the system Service Tag. When calling Dell EMC Technical Support, you can key in the ESC for
auto call routing.
Server Administrator services
45