Connectivity Guide
Table 1709. Battery ID
Name
batteryID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.13
Description Represents unique id for battery.
Syntax Integer
Access Read-only
Table 1710. Battery Maximum Learn Delay
Name
batteryMaxLearnDelay
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.14
Description The maximum amount of time (in hours) that the battery learn cycle can be delayed.
Syntax Integer
Access Read-only
Table 1711. Battery Learn Mode
Name
batteryLearnMode
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.15
Description Indicates current learn mode of the battery.
Possible values:
1: Auto
2: Warn
4: Autowarn
8: Unknown
Syntax Integer
Access Read-only
Battery Connection Table
This table describes the connection between each controller battery on the managed system and its controller. Each controller number in
the table corresponds to that controller instance in the controller Table.
The following object sets up the Battery Connection Table.
Table 1712. Battery Connection Table
Name
batteryConnectionTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.16
Description Denes the battery connection table.
430 Storage Management Group