CLI Guide
The output of the omcong chassis remoteaccess or omcong mainsystem remoteaccess command lists each of the available
congurations. The following table displays the valid parameters:
Table 55. Valid Parameters Of Omcong Chassis Remoteaccess Or Omcong Mainsystem Remoteaccess
name=value pair 1 cong= name=value pair 2 Description
cong=additional ipv4=enable | disable
enable: IPv4 stack to load on iDRAC.
disable: IPv4 stack to ush on iDRAC.
ipv6=enable | disable
enable: Enables IPv6 stack to load on iDRAC.
disable: Disables IPv6 stack to unload on iDRAC.
NOTE: This option requires license to enable or
disable ipv6. If the appropriate license is not installed
or has expired, the system displays an error message.
For more information, see
Dell License Manager
at
dell.com/openmanagemanuals.
cong=advsol characcuminterval=number
number: Sets the character accumulate interval in 5
millisecond intervals.
charsendthreshold=number
number: Sets the number of characters. BMC automatically
sends a serial over LAN data packet that contains the number
of characters as soon as this number of characters (or
greater) has been accepted from the baseboard serial
controller into the BMC.
enableipmi= true | false
true: Enables IPMI over LAN.
false: Disables IPMI over LAN.
enablenic=true | false
true: Enables DRAC NIC.
false: Disables DRAC NIC
nicselection=sharedwithfailoveronall | nic1 |
teamednic1nic2 | dracnic
sharedwithfailoveronall: Congures the new NIC selection
option.
nic1: Enables NIC 1.
teamednic1nic2: Enables NIC teaming functionality.
dracnic: Enables DRAC NIC if DRAC 5 is installed.
NOTE: The nicselection option is supported only on
PowerEdge 10G and 11G systems. From PowerEdge
12G systems onwards, primarynw and failovernw
replaces nicselection.
primarynw=dedicated | lom1 | lom2 | lom3 |
lom4
dedicated: Congures dedicated port as primary network for
remote access.
NOTE: This option requires license to congure
primarynw as dedicated. If the appropriate license is
not installed or has expired, the system displays an
error message. For more information, see
Dell License
Manager
at dell.com/openmanagemanuals.
84 Omcong Managing Components Using The Instrumentation Service