CLI Guide
Table 52. Valid Parameters Of Omcong Chassis Memorymode Or Omcong Mainsystem Memorymode
name=value pair 1 Description
index=<n> Number of the chassis where the memory module resides (the
default is chassis 0, the main system chassis).
redundancy=spare | mirror | disabled | raid5 | dddc
spare: Disables the memory module that has a correctable memory
event and copies the failing module’s data to a spare bank.
mirror: Switches the systems to a mirrored copy of the memory if
the failing module has an uncorrectable memory event. In the mirror
mode, the operating system does not switch back to the original
module until the system reboot.
disabled: Indicates that the system is not to use other available
memory modules if uncorrectable memory events are detected.
raid5: Method of system memory conguration. This is logically
similar to the RAID-5 mode used in hard drive storage systems. This
memory mode provides an extra level of memory checking and error
recovery at the expense of some memory capacity. The RAID mode
supported is RAID level 5 striping with rotational parity.
dddc: The dddc mode enables double device data correction. This
ensures data availability after hard failure of x4 DRAM.
opmode=mirror | optimizer | advecc
mirror: Switches the systems to a mirrored copy of the memory if
the failing module has an uncorrectable memory event. In the mirror
mode, the operating system does not switch back to the original
module until the system reboots.
optimizer: Enables the DRAM controllers to operate independently
in 64-bit mode and provide optimized memory performance.
advanced ECC (advecc): Enables the two DRAM controllers to
combine in 128-bit mode and provide optimized reliability. Memory
that are not teamed by the controllers is not reported to the
operating system.
Omcong
chassis pwrmanagement or omcong mainsystem
pwrmanagement
Use the omcong chassis pwrmanagement or omcong mainsystem pwrmanagement command to congure power cap and manage
proles that control power utilization.
NOTE
: This command is valid only on systems prior to PowerEdge 12G systems.
The following table displays the valid parameters for the command:
Table 53. Valid Parameters Of
Omcong Chassis Pwrmanagement Or Omcong Mainsystem Pwrmanagement
name=value pair 1 name=value pair 2 Description
cong=budget cap=<value>
Sets the threshold value for power budget.
80 Omcong Managing Components Using The Instrumentation Service