CLI Guide
name=value pair 1 attribute= name=value pair 2 setting= Description
• disabled: Disables the processor from
going into a deep sleep state when the
system is not utilized.
BIOS setup settings
The following table lists the BIOS setup attributes supported on PowerEdge systems. The attributes are grouped based on the hardware
conguration. The possible attributes may vary in a specic group. The omcong chassis biossetup command does not display the read-
only attributes.
NOTE: If you have congured the setup password, then, always set the same password when you congure any BIOS settings.
Table 47. BIOS Setup Settings on PowerEdge systems
Group name=value pair 1 attribute= name=value pair 2 setting=
BIOS Option Settings attribute=BootSeq sequence=aliasname1, aliasname2,.....
aliasnameN
attribute=HddSeq sequence=aliasname1, aliasname2,.....
aliasnameN
Boot Settings attribute=BootMode setting=Bios | Ue
attribute=BootSeqRetry setting=Enabled | Disabled
attribute=HddFailover
NOTE: The option is supported only
on 13G and later systems.
setting=Enabled | Disabled
attribute=SetBootOrderFqdd1–
SetBootOrderFqdd16
NOTE: The option is supported only
on 13G and later systems.
setting=<string>
attribute=SetLegacyHddOrder Fqdd1–
SetLegacyHddOrderFqdd16
NOTE: The option is supported only
on 13G and later systems.
setting=<string>
Integrated Devices attribute=EmbVideo setting=Enabled | Disabled
attribute=IntegratedNetwork1 setting=Enabled | DisabledOs
attribute=IntegratedNetwork2 setting=Enabled | DisabledOs
attribute=IntegratedRaid setting=Enabled | Disabled
attribute=IntegratedSas setting=Enabled | Disabled
attribute=InternalSdCard setting=On | O
attribute=InternalSdCardRedundancy setting=Mirror | Disabled
attribute=InternalUsb setting=On | O
attribute=IoatEngine setting=Enabled | Disabled
attribute=OsWatchdogTimer setting=Enabled | Disabled
Omcong Managing Components Using The Instrumentation Service 69