CLI Guide
Peak Time : Wed May 27 00:23:46 2011
Peak Reading : 630 W
Statistics : System Peak Amperage
Measured Since : Mon May 18 16:03:20 2011
Read Time : Tue May 19 04:06:32 2011
Peak Reading : 2.5 A
NOTE: Power Management features are only available for PowerEdge systems that have hot-swappable power supplies and not
systems that have a xed, non-redundant power supply installed.
Omreport chassis pwrsupplies or omreport mainsystem
pwrsupplies
Use the omreport chassis pwrsupplies or omreport mainsystem pwrsupplies command to view properties of the system’s power supplies.
Type:
omreport chassis pwrsupplies
or
omreport mainsystem pwrsupplies
NOTE
: To maintain consistency across the commands, the output format of this command has changed. Change the user scripts
as applicable.
NOTE: On servers in the Dell PowerEdge FX2 series chassis, this command is supported only if the Chassis Management at
Server Mode is set to either Monitor or Manage and Monitor in the CMC, and Server Administrator displays the Chassis
Management at Server Mode as Enabled. For more details, see Chassis Management.
For each power supply prole in the system, the values for the following elds are displayed:
• Status
• Location
• Type
• Rated Input Wattage (in Watts)
• Maximum Output Wattage
• Online Status
• Power Monitoring Capable
Omreport Chassis Remoteaccess Or Omreport Mainsystem
Remoteaccess
Use the omreport chassis remoteaccess or omreport mainsystem remoteaccess command to view general information on baseboard
management controller or integrated Dell remote access controller (BMC/iDRAC) and remote access controller if DRAC is installed. Type:
omreport chassis remoteaccess
or
omreport mainsystem remoteaccess
NOTE
: To maintain consistency across the commands, the output format of this command and the subsequent command levels
has changed. So, you may have to change the user scripts as applicable.
38 omreport Viewing System Status Using The Instrumentation Service