CLI Guide

Table 12. Server administrator output
AC Failover Switch
AC Switch Redundancy
Redundancy Status : Full
Number of devices required for full
redundancy
: 2
Redundancy Mode :
Redundancy Configuration : Input Source Line 1, upon redundancy restoration, return
to Line 1
AC Power Lines
Status : Ok
Location : AC Power Line 1
AC Present : Power Present
Active Source : Active
Status : Ok
Location : AC Power Line 2
AC Present : Power Present
Active Source : Not Active
Server Administrator reports values for the Redundancy Status and Redundancy Mode elds.
Omreport Chassis Batteries Or Omreport Mainsystem
Batteries
Use the omreport chassis batteries or omreport mainsystem batteries command to view battery properties. Type:
omreport chassis batteries
or
omreport mainsystem batteries
Omreport Chassis Bios Or Omreport Mainsystem Bios
Use the omreport chassis bios or omreport mainsystem bios command to view the current BIOS information. Type:
omreport chassis bios
or
omreport mainsystem bios
Server Administrator displays the summary of the BIOS information for the system.
24
omreport Viewing System Status Using The Instrumentation Service