CLI Guide
Omcong global threshold for remaining rated write endurance
Table 214. Omcong Global threshold for remaining rated write endurance
Description Sets the threshold value for Remaining Rated Write Endurance (RRWE) SMART attribute for SSDs. When
the remaining rate write endurance threshold drops below the congured threshold, an alert is logged. For
more information about Global Threshold for Remaining Rated Write Endurance, see the Dell EMC
OpenManage Online Help.
Syntax
omconfig storage globalinfo
action=setremainingratedwriteendurancethreshold type=<sassata| pciessd>
threshold=<1-100>
Example to Settings supported for dierent threshold values for SAS, SATA and PCIe SSDs. The omcong command
syntax for Threshold RRWE value is set between 0 to 100.
NOTE: The RRWE SMART attribute is not supported for SSDs connected to software RAID
Controllers.
Example
omconfig storage globalinfo
action=setremainingratedwriteendurancethreshold type=sassata threshold=0.
Omcong Connector Commands
The following table displays the omcong command syntax required to execute connector tasks.
Table 215.
omcong Connector Commands
Required Command Levels
(1, 2, 3)
Optional name=value pairs
omcong storage connector
action=rescan controller=id connector=id
Omcong Rescan Connector
Table 216.
Omcong Rescan Connector
Description Rescans a controller connector. This command rescans all connectors on the controller and is therefore
similar to performing a controller rescan.
NOTE: This command is not supported on SAS controllers.
Syntax omconfig storage connector action=rescan controller=id connector=id, where
id is the controller ID and the connector ID as reported by the omreport command. To obtain these
values, type
omreport storage controller to display the controller IDs and then type
omreport storage connector controller=ID to display the IDs for the connectors attached
to the controller.
Example to Rescan connector 2 on controller 1.
Example
omconfig storage connector action=rescan controller=1 connector=2
Omcong storage commands 187