CLI Guide
NOTE: To obtain these values, type omreport storage
controller to display the controller IDs and then type
omreport storage pdisk controller=ID to display the IDs for
the physical disks attached to the controller.
NOTE: The <lename> is optional. If <lename> is not
present, a default lename is assigned.
NOTE: Depending on the PCIe SSD or NVMe device the
log le name will be PCIeSSD_<device
name>_<timestamp>.log or NVMe_<device
name>_<timestamp>.log where the <device name> is the
name of the device and timestamp is month, day, hour,
minute and second during which the command is
executed.
Example to Export log on physical disk 3 on connector 0 of controller 1. On a
SAS controller, the physical disk resides in enclosure 2.
Example for SAS controllers
omconfig storage pdisk action=exportlog
controller=1 pdisk=0:2:3
Omcong Convert RAID To Non-RAID
Table 128.
Omcong Convert RAID To Non-RAID
Description
Converts RAID to non-RAID on a physical disk.
Syntax
omconfig storage pdisk
action=convertraidtononraid controller=id
pdisk=<PDISKID>, where id is the controller ID. The <PDISKID>
variable species the physical disk.
NOTE: To obtain these values, type omreport storage
controller to display the controller IDs and then type
omreport storage pdisk controller=ID to display the IDs for
the physical disks attached to the controller.
NOTE: To convert multiple RAID to non-RAID on a given
controller, use omcong storage controller
action=convertraidtononraid command. For more
information, see omcong Convert Multiple RAID To Non-
RAID.
Example to Convert RAID to non-RAID on physical disk 3 on connector 0 of
controller 1. On a SAS controller, the physical disk resides in
enclosure 2.
Example for SAS controllers
omconfig storage pdisk action=raidtononraid
controller=1 pdisk=0:2:3
150 Omcong storage commands