CLI Guide
Example for SCSI, SATA, and ATA controllers
omconfig storage pdisk action=offline
controller=1 pdisk=0:3
Example for SAS controllers
omconfig storage pdisk action=offline
controller=1 pdisk=0:2:3
Omcong Online Physical Disk
Table 117. omcong Online Physical Disk
Description
Brings an oine physical disk back online.
Syntax
omconfig storage pdisk action=online
controller=id pdisk=<PDISKID>, where id is the controller
ID. The <PDISKID> variable species the physical disk.
NOTE: To obtain these values, type omreport storage
controller to display the controller IDs and then type
omreport storage pdisk controller=ID to display the IDs for
the physical disks attached to the controller.
Example to Bring physical disk 3 on connector 0 of controller 1 back online. On a
SAS controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA controllers
omconfig storage pdisk action=online
controller=1 pdisk=0:3
Example for SAS controllers
omconfig storage pdisk action=online
controller=1 pdisk=0:2:30
Omcong Assign Global Hot Spare
Table 118.
omcong Assign Global Hot Spare
Description
Assigns a physical disk as a global hot spare.
Syntax
omconfig storage pdisk
action=assignglobalhotspare controller=id
pdisk=<PDISKID> assign=yes, where id is the controller ID.
The <PDISKID> variable species the physical disk.
NOTE: To obtain these values, type omreport storage
controller to display the controller IDs and then type
omreport storage pdisk controller=ID to display the IDs for
the physical disks attached to the controller.
Example to Assign physical disk 3 on connector 0 of controller 1 as a global hot
spare. On a SAS controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA controllers
omconfig storage pdisk
action=assignglobalhotspare controller=1
pdisk=0:3 assign=yes
Omcong storage commands 145