CLI Guide
NOTE: To obtain these values, type omreport storage
controller to display the controller IDs and then type
omreport storage pdisk controller=ID to display the IDs for
the physical disks attached to the controller.
Example to Erase physical disk 3 on connector 0 of controller 1. On a SAS
controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA controllers
omconfig storage pdisk
action=cryptographicerase controller=1
pdisk=0:3
Example for SAS controllers
omconfig storage pdisk
action=cryptographicerase controller=1
pdisk=0:2:3
Omcong Initialize Physical Disk
Table 115. omcong Initialize Physical Disk
Description
Initializes a physical disk.
Syntax
omconfig storage pdisk action=initialize
controller=id pdisk=id, where id is the controller ID and
physical disk ID as reported by the omreport command.
NOTE: To obtain these values, type omreport storage
controller to display the controller IDs and then type
omreport storage pdisk controller=ID to display the IDs for
the physical disks attached to the controller.
Example to Initialize physical disk 4 on controller 1
Example
omconfig storage pdisk action=initialize
controller=1 pdisk=1:0:4
Omcong Oine Physical Disk
Table 116.
omcong Oine Physical Disk
Description
Makes a physical disk oine.
Syntax
omconfig storage pdisk action=offline
controller=id pdisk=<PDISKID>, where id is the controller
ID. The <PDISKID> variable species the physical disk.
NOTE: To obtain these values, type omreport storage
controller to display the controller IDs and then type
omreport storage pdisk controller=ID to display the IDs for
the physical disks attached to the controller.
Example to Oine physical disk 3 on connector 0 of controller 1. On a SAS
controller, the physical disk resides in enclosure 2.
144 Omcong storage commands