CLI Guide

Example to Prepares physical disk 3 on connector 0 of controller 1 for removal.
On a SAS controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA controllers
omconfig storage pdisk action=remove
controller=1 pdisk=0:3
Example for SAS controllers
omconfig storage pdisk action=remove
controller=1 pdisk=0:2:3
Omcong Instant Erase Secured Physical Disk
Table 113. omcong Instant Erase Secured Physical Disk
Description Erases the given encrypted disk.
NOTE: This command is applicable only on Micron
devices.
Syntax
omconfig storage pdisk
action=instantsecureerase controller=id
pdisk=<PDISKID>, where id is the controller ID. The <PDISKID>
variable species the physical disk.
NOTE: To obtain these values, type omreport storage
controller to display the controller IDs and then type
omreport storage pdisk controller=ID to display the IDs for
the physical disks attached to the controller.
Example to Erase physical disk 3 on connector 0 of controller 1. On a SAS
controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA controllers
omconfig storage pdisk
action=instantsecureerase controller=1
pdisk=0:3
Example for SAS controllers
omconfig storage pdisk
action=instantsecureerase controller=1
pdisk=0:2:3
Omcong Cryptographic Erase Secured Physical Disk
Table 114.
omcong Cryptographic Erase Secured Physical Disk
Description Erases the given encrypted disk.
NOTE: This command is applicable only on Non-Volatile
Memory Express (NVMe) devices.
Syntax
omconfig storage pdisk
action=cryptographicerase controller=id
pdisk=<PDISKID>, where id is the controller ID. The <PDISKID>
variable species the physical disk.
Omcong storage commands 143