CLI Guide

Table 97. omreport Temperature Probe Commands
Required Command Levels (1, 2, 3) and
name=value pair
Optional name=value pairs Use
omreport storage enclosure Displays property information for all
enclosures attached to the system.
controller=id enclosure=<ENCLOSUREID>
info=temps where id is the controller number
and <ENCLOSUREID> is the enclosure ID.
Example for SCSI controllers: controller=0
enclosure=2 info=temps. Example for SAS
controllers: controller=0 enclosure=1:2
info=temps
Displays the temperature probes for the
specied enclosure.
controller=id enclosure=<ENCLOSUREID>
info=temps index=n where id is the controller
number and <ENCLOSUREID> is the
enclosure number and n is the number of a
temperature probe. For example: controller=0
enclosure=2 info=temps index=1
Displays the temperature probes for the
specied enclosure.
Omreport Fan Status
The following table describes the syntax for the omreport Fan commands:
Table 98. omreport Fan Status
Required Command Levels (1, 2, 3) and
name=value pair
Optional name=value pairs Use
omreport storage enclosure Displays property information for all
enclosures attached to the system.
controller=id enclosure=<ENCLOSUREID>
info=fans where id is the controller number
and ENCLOSUREID is the enclosure number.
For example: controller=0 enclosure=2
NOTE: For SCSI controllers, the ID
specied in
enclosure=<ENCLOSUREID> is the
connector number and for Serial
Attached SCSI (SAS) controllers, ID
is the
connectorNumber:EnclosureIndex.
Displays the fans for the specied enclosure.
controller=id enclosure=<ENCLOSUREID>
info=fans index=n where id is the controller
number and ENCLOSUREID is the enclosure
number and n is the number of a fan. For
example: controller=0 enclosure=2 info=fans
index=1
Displays the specied fan.
Omreport storage commands 135