Components and events of platform events
The following table lists the components and the events for which you can set platform events. Components are listed in alphabetical order,
except that warning events always precede failure events for a component.
Table 70. Valid Parameters Of Omcong System Platformevents
Event Name Description
alertsenable=true | false
true: Enables generation of platform event lter alerts.
false: Disables generation of platform event lter alerts.
NOTE: This setting is independent of the individual platform event lter alert
settings. For a platform event lter to generate an alert, both the individual alert
and the global event alert are enabled.
event=batterywarn Sets action or enables or disables alert generation when a battery device detects that the
battery is pending a failure condition.
event=batteryfail Sets action or enables or disables alert generation when a battery device detects that the
battery has failed.
event=discretevolt Sets action or enables or disables alert generation when a discrete voltage probe detects that
the voltage is too low for proper operation.
event=fanfail Sets action or enables or disables alert generation when a fan probe detects that the fan is
running too slow or not at all.
event=hardwarelogfail Enables or disables alert generation when a hardware log detects a failure value.
event=intrusion Sets action or enables or disables alert generation when a chassis is opened.
event=powerwarn Sets action or enables or disables alert generation when a power device probe detects that
the power supply, voltage regulator module, or DC to DC converter is pending a failure
condition.
event=powerabsent Sets action or enables or disables alert generation when a processor probe detects that the
power supply is absent.
event=powerfail Sets action or enables or disables alert generation when a power device probe detects that
the power supply, voltage regulator module, or DC to DC converter has failed.
event=processorwarn Sets action or enables or disables alert generation when a processor probe detects that the
processor is running at less than peak performance or speed.
event=processorfail Sets action or enables or disables alert generation when a processor probe detects that the
processor has failed.
event=processorabsent Sets action or enables or disables alert generation when a processor probe detects that the
processor is absent.
event=redundegrad Sets action or enables or disables alert generation when the system fans and/or power
supplies become inoperative, resulting in less than full redundancy for that component.
event=redunlost Sets action or enables or disables alert generation when the system fans and/or power
supplies become inoperative, resulting in a lost or a no redundant components working
condition for that component.
event=systempowerwarn Sets actions when a power consumption probe detects a warning value.
event=systempowerfail Sets actions when a power consumption probe detects a failure value.