CLI Guide

Table 68. Valid Parameters Of Omcong System Pedestinations Or Omcong Servermodule Pedestinations
name=Value Pair Description
destenable=true | false
true: Enables an individual platform event lter destination after a valid IP address has been set.
false: Disables an individual platform event lter.
index=number Sets the index for the destination.
ipaddress=<ipv4 address | ipv6
address | fqdn>
Sets the IP address for the destination.
NOTE: On 12th generation of PowerEdge systems with iDRAC7 specic versions, ipaddress
can also be a Fully Qualied Domain Name (FQDN).
communitystr=text Sets the text string that acts as a password and is used to authenticate SNMP messages sent
between the BMC and the destination management station.
Omcong system platformevents or omcong servermodule
platformevents
Use the omcong system platformevents or omcong servermodule platformevents command to congure shutdown action, if any, taken
for a specic platform event. You can also enable or disable platform event lter alert generation.
CAUTION
: If you set a platform event shutdown action to anything other than
none
or
power reduction
, the system is forcefully
shut down when the specied event occurs. This shutdown is initiated by rmware and is carried out without rst shutting down
the operating system or any of the applications running on your system.
The following table displays the valid parameters for the command.
NOTE
: Alert settings are mutually exclusive and you can set one at a time only. The action settings are also mutually exclusive
and you can set one at a time only. However, alert and action settings are not mutually exclusive of each other.
Table 69. Parameters For Alert Action Command
Action Description
action=disable Disables the SNMP alert.
action=enable Enables the SNMP alert.
action=none Takes no action when the system is hung or has crashed.
action=powercycle Turns o the electrical power to the system, pauses, turns on the power, and reboots the system.
action=powero Turns o the electrical power to the system.
action=powerreduction Reduces the processor speed until the power consumption comes down and reaches below the warning
threshold. If the system power consumption remains below the warning threshold, increase the processor
speed.
NOTE: This action is applicable only for PowerEdge Rack and Tower systems earlier than 11th
generation of PowerEdge systems.
action=reboot Forces the operating system to shut down and initiates system startup, performs BIOS checks, and reloads
the operating system.
Omcong Managing Components Using The Instrumentation Service 111