CLI Guide

Alert Action Setting Description
NOTE: On Linux systems, user or user groups upgraded to
administrator or administrator groups cannot congure
this alert action setting.
execapp=false Disables the executable application.
Components and events for alert actions
The following table provides the events for which you can set alert actions. Components are listed in alphabetical order, except that
warning events always precede failure events for a component.
Table 67. Valid Parameters Of Events for Alert Actions
Event Name Description
event=batterywarn Sets actions when a battery probe detects a warning value.
event=batteryfail Sets actions when a battery probe detects a failure value.
event=fanwarn Sets actions when a fan probe detects a warning value.
event=fanfail Sets actions when a fan probe detects a failure value.
event=hardwarelogwarn Sets actions when a hardware log detects a warning value.
event=hardwarelogfull Sets actions when a hardware log is full.
event=intrusion Sets actions when a chassis intrusion event is detected.
event=memprefail Sets actions when a memory probe detects a prefailure value.
event=memfail Sets actions when a memory probe detects a failure value.
event=systempeakpower Sets actions when a power consumption probe detects peak power value.
event=systempowerwarn Sets actions when a power consumption probe detects a warning value.
event=systempowerfail Sets actions when a power consumption probe detects a failure value.
event=powersupply Sets actions when a power supply probe detects a failure value.
event=powersupplywarn Sets actions when a power supply probe detects a warning value.
event=processorwarn Sets actions when a processor probe detects a warning value.
event=processorfail Sets actions when a processor probe detects a failure value.
event=redundegrad Sets actions when a redundant component becomes inoperative, resulting in less than full
redundancy for that component.
event=redunlost Sets actions when one or more redundant components become inoperative, resulting in a lost or a
"no redundant components working" condition for that component.
event=tempwarn Sets actions when a temperature probe detects a warning value.
event=tempfail Sets actions when a temperature probe detects a failure value.
event=voltwarn Sets actions when a voltage probe detects a warning value.
event=voltfail Sets actions when a voltage probe detects a failure value.
event=watchdogasr Sets actions that Server Administrator performs on the next system startup after a watchdog
Automatic System Recovery (ASR) is performed for a hung operating system.
event=removableashmediapresen
t
Sets actions that Server Administrator performs when the system detects a removable ash media.
108 Omcong Managing Components Using The Instrumentation Service