Property Denition
State Displays the status of the enclosure or backplane. Possible values are:
• Ready — The enclosure or backplane is functioning normally.
• Degraded — The enclosure has encountered a failure and is operating in a
degraded state. This state does not apply to backplanes.
• Failed — The enclosure or backplane has encountered a failure and is no
longer functioning.
Connector Displays the number of connectors attached to the enclosures or backplanes.
This number matches the number connector on the controller hardware.
Depending on the controller type, the connector can be either a SCSI channel
or a SAS port.
Enclosure ID Displays the enclosure ID assigned to the enclosure by Storage Management.
Storage Management numbers the enclosures attached to the controller
starting with zero. This number is the same as the enclosure ID number
reported by the omreport command. For information on Command Line
Interface, see the Server Administrator Command Line Interface User’s Guide.
Target ID Displays the SCSI ID of the backplane (internal to the server) or the enclosure
to which the controller connector is attached. The default value is six.
Conguration Displays the mode in which the enclosure is operating. Possible values are:
• Joined — Indicates that the enclosure is operating in the joined-bus mode.
• Split — Indicates that the enclosure is operating in the split-bus mode.
• Unied — Indicates that enclosure is operating in the unied mode.
• Clustered — Indicates that the enclosure is operating in cluster mode.
Clustered mode is only available on cluster-enabled RAID controllers. For
more information, see Background Initialization On PERC Controllers.
For more information on joined, split, and cluster modes, see the enclosure
hardware documentation. For information on how to cable the enclosure to
accommodate these dierent modes, see the enclosure hardware
documentation.
The bus conguration switch when toggled on a 220S or 221S enclosure, the
enclosure should be turned o. For more information, see Changing The Mode
On 220S And 221S Enclosures.
Older 200S enclosures with a version 1.8 kernel that only have one EMM may
display Split Bus mode and not Joined Bus mode. Joined Bus or Clustered
modes may display when applicable in these circumstances.
Firmware Version Displays the version of the enclosure rmware.
NOTE: For systems supporting multiple backplanes, the rmware
version appears as upstream and downstream versions.
Service Tag Displays the enclosure Service Tag. The enclosure is identied by a unique
Service Tag number. This information is used to route support calls to the
appropriate personnel.
Express Service Code The enclosure is identied by a unique Express Service Code number. This
information is used to route support calls to the appropriate personnel.
Asset Tag Displays the asset tag information for the enclosure. You can change this
property using the Setting Asset Data task.
94 Enclosures And Backplanes