Users Guide
Enclosure Power Supplies
The enclosure power supplies are displayed under the Power Supplies object in the tree view. You can select the Power Supplies object to
view the status information.
Power Supply Properties
Table 22. Power Supply Properties
Property Denition
Status These icons represent the severity or health of the storage component.
— Normal/OK
— Warning/Non-critical
— Critical/Failure/Error
For more information, see Storage Component Severity.
Name Displays the name of the power supply.
State Displays the status of the power supply.
• Ready — The power supply is functioning normally.
• Degraded — The power supply has encountered a failure and is operating in a
degraded state.
• Failed — The power supply has encountered a failure and is no longer functioning.
Storage Management is unable to communicate with the enclosure using SES
commands. The Failed state is displayed when the enclosure does not respond to a
status query from Storage Management for any reason. For example, This state is
displayed when you disconnect the cable.
• Missing — The power supply is not present in the enclosure.
Part Number Displays the part number of the power supply.
This property is not displayed for the 22xS enclosures that have E.17 rmware or later.
Firmware Version Displays the rmware version number of the power supply.
Enclosure Temperature Probes
The enclosure temperature probes are displayed under the Temperatures object. You can select the Temperatures object to view the
status information. The status information includes the current temperature in Celsius and the warning and failure thresholds for the
temperature probe.
The failure threshold has a default value that cannot be changed. However, you can set the warning threshold.
Enclosures And Backplanes
89