Users Guide

Changing The Read, Write, Or Disk Cache Policy Of A Virtual
Disk
1 Select the new policy from the Read Policy, Write Policy, and Disk Cache Policy drop-down menus.
2 Click Apply Changes.
To exit without changing the virtual disk policy, click Go Back To Virtual Disk Page.
To Locate Change Policy In Storage Management
1 In the Server Administrator window, under the system tree, expand Storage to display the controller objects.
2 Expand a Controller object.
3 Select the Virtual Disks object.
4 Select Change Policy from the Available Tasks drop-down box.
5 Click Execute.
Split Mirror
Does my controller support this feature? See Supported Features.
Use the Split Mirror task to separate mirrored data originally congured as a RAID 1, RAID 1-concatenated, or RAID 10 virtual disk. Splitting
a RAID 1 or RAID 1-concatenated mirror creates two concatenated non-redundant virtual disks. Splitting a RAID 10 mirror creates two RAID
0 (striped) non-redundant virtual disks. Data is not lost during this operation.
NOTE
: On Linux operating systems, a Split Mirror cannot be performed on a mounted virtual disk. For this reason, a Split Mirror
cannot be performed on the boot drive.
Splitting A Mirror
Click Split Mirror. To exit without splitting the mirror, click Go Back To Virtual Disk Page.
CAUTION
: Your virtual disk is longer redundant after performing a Split Mirror operation.
To Locate Split Mirror In Storage Management
1 In the Server Administrator window, under the system tree, expand Storage to display the controller objects.
2 Expand a controller object.
3 Select the Virtual Disks object.
4 Select Split Mirror from the Available Tasks drop-down menu.
5 Click Execute.
Unmirror
Does my controller support this feature? See Supported Features.
142