Release Notes
• JIT-97151: Full view of Physical Disk Page in Server Administrator GUI, the negotiated speed for a 6Gbps drive capable speed is
intermittently shown as 12Gbps.
• JIT-94842: Storage Management carries SHA1 signed library ( storelibIR) in the current release.
• JIT-95176: The Physical disks available in MX5016s connected to MX7000 chassis slot 8 does not support RAID-10 intelligent mirror
virtual disk creation.
• JIT-92467: The dynamic mapping of an enclosure for the rst time also displays the unmapped enclosure for a short period. Refresh
the Server Administrator page to remove the unmapped enclosure entries.
• JIT-104975: In storage management, FAN speed changes will not update dynamically.
Workaround: Data manager service restart will update the latest FAN speed.
• JIT-106970:After change controller mode operation is performed, two alerts that are generated have the same alert ID and description.
• If the controller name is not displayed in the alert message, check the controller information for mapping the controller ID and controller
name.
• JIT-106295: Critical and warning a lert is not displayed on Enhanced Event Message alert for Physical Device and Controller ID on
Available Spare threshold.
• JIT-103891: Duplicate alerts for power supply removal are displayed while enclosure power supply cable is removed.
• JIT-103962: The Storage Management displays the removal and insertion alerts intermittently on EMM for HBA controllers during
physical drive hot-plug-out and hot-plug-in.
• JIT-104973: On enhanced mode, an alert is displayed as A Device is inserted in the enclosure for both Power unit and FAN inserted into
enclosure. The message does not state the specic device inserted.
• JIT-97106: You cannot create a partial RAID50 or a RAID60 virtual disk from IDRAC/HII. When the Foreign conguration drives are
imported on the rst RAID50 or RAID60 virtual disk with physical drive that is created on Storage Management.
• JIT-103150: On PowerEdge R940XA with dual backplane, the Storage tree does not display the Enclosure ID intermittently during
insertion or removal of multiple drives.
Workaround: Restart the Data-Manager service to resolve this discrepancy.
• JIT-94890: For fully populated chassis, the Storage Management system takes few minutes to load the storage components.
• JIT-101739: If an EMM is removed from MX5016s sled, EMM failure or removal alert is not observed on Server Administrator alerts.
• JIT-109008: Storage Management is enumerating more than one backplane that is not connected to SWRAID controller under SWRAID
controller (S140) on PowerEdge R740xd2 system.
• JIT-98675: On Server Administrator page, a delay is observed on hot-pluggable devices when hot-plugged in or out on HBA 330 MMZ.
• JIT-117535: On the Web Server the Command Line Interface commands does not display the correct exit codes for all sub-queries
when Server Administrator services is not running.
• JIT-110132: When the enclosure is hot plug-in to the 12GBPS HBA controller observes an additional physical disk id in alert log page.
• JIT-108887: The alert log displays a message as XML not well-formed after a server restart and post controller mode change operation
intermittently.
Work-around: Clear Logs and restart the service.
• JIT-113370: RAID 10 virtual disk creation using intelligent mirroring fails, as the support is not available from this release of OpenManage.
• JIT-113374: While creation of R10, R50 and R60 virtual disks the Storage Management does not display the dedicated hot-spare
suggestions for all disks, if the user selects dierent size of physical disks as part of virtual disk creation.
Work around: Dedicated hot-spare can be assigned after creation of virtual disk using assign or unassign dedicated hot-spare option.
• JIT-111625 and JIT-112746: In a maximum conguration setup i.e. eight enclosures connected to PERC H840 controller, performing
creating or deleting virtual disk operation multiple times with more than 160 plus physical drives on systems running ESXi operating
system.We observe core or virtual disk creation failure.
Work around: Restart sfcbd service.