Connectivity Guide
Table 341. Voltage Probe Lower Critical Threshold
Name
voltageProbeLowerCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.13
Description This attribute defines the lower critical threshold of the voltage probe. The value is an integer
representing the voltage of the threshold in millivolts.
Syntax Signed32BitRange
Access Read-only
Table 342. Voltage Probe Lower NonRecoverable Threshold
Name
voltageProbeLowerNonRecoverableThreshold
Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.14
Description This attribute defines the lower non-recoverable threshold of the voltage probe. The value is
an integer representing the voltage of the threshold in millivolts.
Syntax Signed32BitRange
Access Read-only
Table 343. Voltage Probe Probe Capabilities
Name
voltageProbeProbeCapabilities
Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.15
Description This attribute defines the probe capabilities of the voltage probe.
Syntax ProbeCapabilitiesFlags
Access Read-only
Table 344. Voltage Probe Discrete Reading
Name
voltageProbeDiscreteReading
Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.16
Description This attribute defines the reading for a voltage probe of type voltageProbeTypeIsDiscrete.
When the value for voltageProbeType is other than voltageProbeTypeIsDiscrete, a value is not
returned for this attribute. When the value for voltageProbeType is
voltageProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the
probe.
Syntax VoltageDiscreteReadingEnum
Access Read-only
Amperage Probe Table
The amperage probe objects provide information about the system amperage probe in which the iDRAC resides.
Table 345. Amperage Probe Chassis Index
Name
amperageProbechassisIndex
Object ID 1.3.6.1.4.1.674.10892.5.4.600.30.1.1
Description This attribute defines the index (one based) of the system chassis.
Syntax ObjectRange
Access Read-only
80 iDRAC MIB