Connectivity Guide

Table 175. DRsCMC PSUTableEntry(continued)
Access Not-accessible
CMC Power Information
The following MIB tables provide information on the chassis power.
Table 176. DRsChassisIndex
Name
drsChassisIndex
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.1
Description Defines the index (one-based) of the associated chassis.
Syntax DellCMCPowerIndexRange
Access Read-only
Table 177. DRsPotentialPower
Name
drsPotentialPower
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.2
Description Defines the power (in watts) required by the chassis infrastructure, along with the maximum
power requirements for all systems currently turned on.
Syntax DellPowerReading
Access Read-only
Table 178. DRsIdlePower
Name
drsIdlePower
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.3
Description Defines the power (in watts) required by the chassis infrastructure, along with the minimum
power requirements for all systems currently turned on.
Syntax DellPowerReading
Access Read-only
Table 179. DRsMaxPowerSpecification
Name
drsMaxPowerSpecification
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.4
Description Defines the power limit (in watts) at which server throttling takes place.
Syntax DellPowerReading
Access Read-only
Table 180. DRsPowerSurplus
Name
drsPowerSurplus
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.5
Description Defines the power surplus (in watts) remaining above the drsPotentialPower reading.
Syntax DellPowerReading
Access Read-only
Chassis Management Controller Group 41