Connectivity Guide
Enclosure Power Supply Table
The objects provide information about the Enclosure Power Supply group in storage.
NOTE: The Storage Details Group is introduced in VRTX CMC from this release. The iDRAC and CMC have the same
Storage attributes with some modification in CMC. The Object ID mentioned example:
1.3.6.1.4.1.674.10892.
5.5
.1.20.130.9.1.1 for the table group are attributes for checking on iDRAC. To check the
corresponding set of attributes for VRTX CMC systems, use the Object ID example:
1.3.6.1.4.1.674.10892.
2.6
.1.20.130.9.1.1.
Table 534. Enclosure Power Supply Number
Name
enclosurePowerSupplyNumber
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.1
Description Instance number of this power supply unit.
Syntax INTEGER
Access read-only
Table 535. Enclosure Power Supply Name
Name
enclosurePowerSupplyName
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.2
Description The power supply unit's name as represented in Storage Management.
Syntax DisplayString
Access read-only
Table 536. Enclosure Power Supply State
Name
enclosurePowerSupplyState
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.4
Description The current state of this power supply unit. Possible states:
1. The current state could not be determined
2. The power supply unit is operating normally
3. The power supply unit has encountered a hardware problem or is not responding
4. The power supply unit is no longer connected to the enclosure or there exists a
problem communicating to it
5. The power supply unit is unstable
Syntax INTEGER
Access read-only
Table 537. Enclosure Power Supply Part Number
Name
enclosurePowerSupplyPartNumber
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.7
Description The part number of the power supply unit.
Syntax DisplayString
Access read-only
Table 538. Enclosure Power Supply Component Status
Name
enclosurePowerSupplyComponentStatus
122 iDRAC MIB