Users Guide

Virtual Disk Task Name PERC S150
Reconfigure Yes
Change Policy Yes
Delete Last Virtual Disk Yes
Delete (any) Virtual Disk Yes
Check Consistency Yes
Disk Cache Policy Yes
Virtual Disk Specifications For PERC Software RAID
Controllers
Table 47. Virtual Disk Specifications for S150 Controllers
Virtual Disk Specification PERC S150
Maximum Number of Virtual Disks per Controller 16
Minimum Virtual Disk Size 100MB
Maximum Virtual Disk Size None
Maximum Number of Spans per Virtual Disk NA
Maximum Number of Physical Disks per Span NA
Minimum Stripe Size 64 K
Maximum Stripe Size 64 K
Maximum Number of Virtual Disks per Physical Disk 8
Maximum Number of Physical Disks that Can Be Concatenated NA
Maximum Number of Physical Disks in a RAID 0 16
Maximum Physical Disks in a RAID 1 2
Maximum Number of Physical Disks in a RAID 5 16
Maximum Number of Physical Disks in a RAID 10 16
Minimum Number of Physical Disks that Can Be Concatenated NA
Minimum Number of Physical Disks in a RAID 0 2
Minimum Number of Physical Disks in a RAID 1 2
Minimum Number of Physical Disks in a RAID 5 3
Minimum Number of Physical Disks in a RAID 10 4
NOTE: When creating virtual disks using software RAID controllers, the information related to the physical disks linked
to the virtual disk is enumerated or displayed on Storage Management after a short delay. This delay in displaying the
information does not cause any functional limitation. If you are creating partial virtual disks, it is recommended that you
provide Storage Management adequate time between each partial virtual disk creation process.
RAID Levels Supported By The PERC Software RAID
Controllers
156
Supported Features