CLI Guide

Specify a value for minimum and maximum warning thresholds
To specify values for the temperature probe warning thresholds, you must specify the number of the probe you are configuring and the
minimum and/or maximum warning threshold value. In the following example, the probe that is being configured is probe 4:
omconfig chassis temps index=4 minwarnthresh=11.2 maxwarnthresh=58.7
or
omconfig mainsystem temps index=4 minwarnthresh=11.2 maxwarnthresh=58.7
When you issue the command and the system sets the values you specify, the following message is displayed:
Temperature probe warning threshold(s) set successfully.
Omconfig Chassis Volts Or Omconfig Mainsystem Volts
Use the omconfig chassis volts or omconfig mainsystem volts command to set voltage probe warning thresholds. As
with other components, you can view both warning and failure threshold values, but you cannot set failure threshold values. The system
manufacturer sets the minimum and maximum values for the failure thresholds.
Valid parameters for voltage warning thresholds
The following table displays the valid parameters for setting voltage warning threshold values.
NOTE:
Threshold values that you can set vary from one system configuration to another.
Table 59. Valid Parameters Of Omconfig Chassis Volts Or Omconfig Mainsystem Volts
name=value pair Description
index=<n> Probe index (specify).
warnthresh=default Sets minimum and maximum warning threshold values to default.
minwarnthresh=<n> Sets minimum warning threshold value (three decimal places).
maxwarnthresh=<n> Sets maximum warning threshold value (three decimal places).
Specify A Value For Minimum And Maximum Warning Thresholds
To specify values for the voltage probe warning thresholds, you must specify the number of the probe you are configuring and the
minimum and/or maximum warning threshold values.
In the following example, the probe being configured is probe 0:
omconfig chassis volts index=0 minwarnthresh=1.900 maxwarnthresh=2.250
or
omconfig mainsystem volts index=0 minwarnthresh=1.900 maxwarnthresh=2.250
When you issue the command and the system sets the values you specify, the following message is displayed:
Voltage probe warning threshold(s) set successfully.
Omconfig Preferences
Use the omconfig preferences command to set system preferences. Use the command line to specify the user levels to access
Server Administrator and to configure the Active Directory service.
Omconfig Managing Components Using The Instrumentation Service
87