CLI Guide

Usage of Extipmiusergroup
The following table displays the usage of extipmiusergroup=custom:
Table 57. Usage Of extipmiusergroup
name=value pair 1 name=value pair 2 name=value pair 3 Description
config=user
id=user id
extipmiusergroup=custom
NOTE:
extipmiusergroup user
group is available only on
the Dell 10G blade
systems.
id=user id
loginidrac=true | false true or false: Enables or
disables logging into iDRAC.
configureidrac=true | false true or false: Enables or
disables configuration of iDRAC.
Omconfig Chassis Temps Or Omconfig Mainsystem Temps
Use the omconfig chassis temps or omconfig mainsystem temps command to set warning thresholds for temperature
probes. As with other components, you can view both warning and failure threshold values, but you cannot set failure threshold values.
The system manufacturer sets the minimum and maximum failure threshold values.
NOTE:
Threshold values that you can set vary from one system configuration to another.
Valid Parameters For Temperature Warning Thresholds
The following table displays the valid parameters for setting temperature warning thresholds:
Table 58. Valid Parameters For Omconfig Chassis Temps Or Omconfig Mainsystem Temps
name=value pair Description
index=<n> Number of the probe or probe index (specify).
warnthresh=default Sets the minimum and maximum warning threshold values to default.
minwarnthresh=<n> Sets the minimum warning threshold values (one decimal place).
maxwarnthresh=<n> Sets the maximum warning threshold values (one decimal place).
Setting Minimum And Maximum Warning Threshold Values
To set both the upper and lower temperature warning threshold values to the recommended default value, type:
omconfig chassis temps index=0 warnthresh=default
or
omconfig mainsystem temps index=0 warnthresh=default
You cannot default one value and set another. In other words, if you set the minimum warning threshold value to the default value, you are
also selecting the default value for the maximum warning threshold value.
NOTE:
The capabilities for managing sensors vary by systems.
86 Omconfig Managing Components Using The Instrumentation Service