CLI Guide
name=value pair 1
config=
name=value pair 2 Description
NOTE: This option requires license to enable or
disable ipv6. If the appropriate license is not
installed or has expired, the system displays an error
message. For more information, see
Dell License
Manager
at dell.com/openmanagemanuals.
config=advsol characcuminterval=number
number: Sets the character accumulate interval in 5
millisecond intervals.
charsendthreshold=number
number: Sets the number of characters. BMC automatically
sends a serial over LAN data packet that contains the number
of characters as soon as this number of characters (or
greater) has been accepted from the baseboard serial
controller into the BMC.
enableipmi= true | false
true: Enables IPMI over LAN.
false: Disables IPMI over LAN.
enablenic=true | false
true: Enables DRAC NIC.
false: Disables DRAC NIC
nicselection=sharedwithfailoveronall | nic1 |
teamednic1nic2 | dracnic
sharedwithfailoveronall: Configures the new NIC selection
option.
nic1: Enables NIC 1.
teamednic1nic2: Enables NIC teaming functionality.
dracnic: Enables DRAC NIC if DRAC 5 is installed.
NOTE: The nicselection option is supported only
on PowerEdge 10G and 11G systems. From
PowerEdge 12G systems onwards, primarynw and
failovernw replaces nicselection.
primarynw=dedicated | lom1 | lom2 | lom3 |
lom4
dedicated: Configures dedicated port as primary network for
remote access.
NOTE: This option requires license to configure
primarynw as dedicated. If the appropriate
license is not installed or has expired, the system
displays an error message. For more information,
see
Dell License Manager
at dell.com/
openmanagemanuals.
lom 1: Configures lom1 port as the primary network for
remote access.
lom 2: Configures lom2 port as the primary network for
remote access.
lom 3: Configures lom3 port as the primary network for
remote access.
lom 4: Configures lom4 port as the primary network for
remote access.
NOTE: The primarynw option is supported from
PowerEdge12G systems onward. If the primarynw
is set to dedicated, then set failovernw to none.
NOTE: If the primarynw is set to dedicated, then
set failovernw to none.
80 Omconfig Managing Components Using The Instrumentation Service