CLI Guide

or
omconfig mainsystem fans index=0 minwarnthresh=4580 maxwarnthresh=9160
When you issue the command and the system sets the values you specify, the following message is displayed:
Fan probe warning threshold(s) set successfully.
Omconfig chassis frontpanel or omconfig mainsystem
frontpanel
Use the omconfig chassis frontpanel or omconfig mainsystem frontpanel command to:
configure the power button and the Nonmasking Interrupt (NMI) button
configure the LCD to display:
No information
Custom information
Default system information
Service tag, system name
Remote access MAC addresses
System power
Remote access IP address
Ambient temperature of the system
Remote access IPv4 address
Remote access IPv6 address
Specify and configure the LCD line number
View the encryption state report of the LCD
Configure LCD to indicate an active remote session when the Kernel-based Virtual Machine (KVM) is available
NOTE:
You can configure the Power and NMI buttons only if they are present on the system.
The following table displays the valid parameters for the command:
Table 49. Valid Parameters Of Omconfig Chassis Frontpanel Or Omconfig Mainsystem Frontpanel
name=value pair 1 name=value pair 2 Description
lcdindex=<index> NA Specifies the LCD line number.
config=none | default | custom NA
none: Sets the LCD text to none.
default: Sets the LCD text to default.
custom: Sets the LCD text to custom.
text=<custom text> NA Sets the custom text for LCD when
config=custom.
nmibutton=enable | disable NA
enable: Enables the NMI button on the
system.
disable: Disables the NMI button on the
system.
powerbutton=enable | disable NA
true: Enables the Power button on the
system.
false: Disables the Power button on the
system.
config=sysname NA Sets the name of the system.
config=syspower NA Sets the system power information.
config=servicetag NA Sets the system service tag information.
config=remoteaccessipv4 NA Sets the remote access IPv4 information.
Omconfig Managing Components Using The Instrumentation Service 73