CLI Guide

Removable Flash Media Failure
NOTE: Storage Controller Battery Warning and Storage Controller Battery Failure events are not available on blade
systems.
NOTE: System Power Probe Warning is not applicable to blade systems.
Omreport System Assetinfo Or Omreport Servermodule
Assetinfo
Use the omreport system assetinfo or omreport servermodule assetinfo command to see cost of ownership data for
the system, such as acquisition, depreciation, and warranty information. To
set any of these fields, use the omconfig system
assetinfo or omconfig servermodule assetinfo command. For more information, see Omconfig System Or Servermodule
Assetinfo Editing Cost Of Ownership Values.
Omreport system events or omreport servermodule events
Use the omreport system events or omreport servermodule events command to view the currently enabled or disabled
SNMP traps. Type:
omreport system events
or
omreport servermodule events
This command displays a summary of each component in the system for which events are generated. For each component, the report
shows which severities are set to report and which severities are set not to report. The following is an example output for a few
components:
Current SNMP Trap Configuration
-----------
System
-----------
Settings
Enable: Informational, Warning and Critical
Disable: None
---------------
Power Supplies
----------------
Settings
Enable: Informational, Warning and Critical
Disable: None
-----------
Fans
-----------
Settings
Enable: Critical
Disable: Informational, Warning, and Critical
---------------------
Removable Flash Media
---------------------
Settings
Enable: Informational, Warning and Critical
Disable: None
The full report lists the settings for all components in the system for which events are generated.
omreport Viewing System Status Using The Instrumentation Service
43