CLI Guide
Omreport Chassis Slots Or Omreport Mainsystem Slots
Use the omreport chassis slots or omreport mainsystem slots command to view properties of the system’s slots. Type:
omreport chassis slots index=n
or
omreport mainsystem slots index=n
The index parameter is optional. If you do not specify the index, Server Administrator displays properties for all of the slots in the
system. If you specify the index, Server Administrator displays properties for a specific slot.
NOTE: To maintain consistency across the commands, the output format of this command has changed. Change the
user scripts as applicable.
For each slot in the system, values display for the following fields given in the following table:
Table 32. Valid Parameters Of Omreport Chassis Slots Or Omreport Mainsystem Slots
Field Description
Index Number of the slot in the system.
Slot ID Silk screen name printed on the system's motherboard next to the slot. Alphanumeric text uniquely identifies each slot in
the system.
Adapter Name and/or type of the card that fits into the slot, for example, a storage array controller, SCSI adapter, iDRAC
Enterprise, or HBA.
Data Bus
Width
Width, in bits, of the information pathway between the components of a system. The range of the data bus width is
from 16 to 64 bits.
Omreport chassis temps or Omreport mainsystem temps
Use the omreport chassis temps or omreport mainsystem temps command to view properties of the system’s
temperature probes. Type:
omreport chassis temps index=n
or
omreport mainsystem temps index=n
The index parameter is optional. If you do not specify the index, Server Administrator displays a summary of status, readings, and
thresholds set for any temperature probes that are present on the system. If you specify the index, Server Administrator displays the
summary for a specific temperature probe.
NOTE:
On servers in the Dell PowerEdge FX2 series chassis, this command is supported only if the Chassis Management
at Server Mode is set to either Monitor or Manage and Monitor in the CMC, and Server Administrator displays the
Chassis Management at Server Mode as Enabled. For more details, see Chassis Management.
Omreport Chassis Volts Or Omreport Mainsystem Volts
Use the omreport chassis volts or omreport mainsystem volts command to view properties of the system’s voltage
probes. Type:
omreport chassis volts index=n
or
omreport mainsystem volts index=n
omreport Viewing System Status Using The Instrumentation Service
39