CLI Guide

or
omreport chassis hwperformance
Server Administrator displays a summary of the system’s hardware performance degradation information.
NOTE: This command is applicable only to selected Dell 10G systems that support PMBus.
Depending on the system’s configuration, you may notice the following output:
Table 14. System configuration output
Hardware Performance
Index : 0
Probe Name : System Board Power Optimized
Status : Normal
Cause : [N/A]
Omreport Chassis Info Or Omreport Mainsystem Info
Use the omreport chassis info or omreport mainsystem info command to see a summary of installed component
versions. Type:
omreport chassis info index=n
or
omreport mainsystem info index=n
The index parameter specifies a chassis number and is optional. If you do not specify the index, Server Administrator displays summary
chassis information for each chassis. If you specify the index, Server Administrator displays summary information for a specific chassis.
NOTE:
If iDRAC is installed, Server Administrator displays the Lifecycle Controller version. If BMC is installed, Server
Administrator displays the USC version.
Depending on the system’s configuration, you may notice the following output:
Table 15. System configuration output
Index : 0
Chassis Name : Main System Chassis
Host Name : WIN-27C02UQFV6L
iDRAC7 Version : 1.00
Chassis Model : PowerEdge R720
Chassis Lock : Present
Chassis Service Tag : 7654321
Express Service Code : 15608862073
Chassis Asset Tag : c
Omreport Chassis Intrusion
Use the omreport chassis intrusion command to find out whether the cover of the system is open or not. Server Administrator
tracks chassis intrusion events because intrusions may indicate an attempt to steal a system component, or to perform unauthorized
maintenance on the system. Type:
omreport chassis intrusion
omreport Viewing System Status Using The Instrumentation Service