CLI Guide
Chassis management
On servers with Dell PowerEdge FX2 series chassis, when Chassis Management at Server Mode is set to Monitor or Manage and
Monitor in CMC, OMSA displays Chassis Management at Server Mode as Enabled and displays the Fans, Power Supplies, and
Temperature sensor details. The sensor details are read-only. When
Chassis Management at Server Mode is set to None in CMC,
OMSA displays
Chassis Management at Server Mode as Disabled and displays only the server temperature sensors (not chassis
temperature sensors).
Related Links
• omreport chassis fans or omreport mainsystem fans
• omreport chassis pwrsupplies or omreport mainsystem pwrsupplies
• omreport chassis temps or omreport mainsystem temps
Omreport chassis acswitch or omreport mainsystem
acswitch
Use the omreport chassis acswitch or omreport mainsystem acswitch command if the system has redundant AC
power lines that are configured in a failover arrangement. Type:
omreport chassis acswitch
or
omreport mainsystem acswitch
Server Administrator displays the following output:
Table 12. Server administrator output
AC Failover Switch
AC Switch Redundancy
Redundancy Status : Full
Number of devices required for full
redundancy
: 2
Redundancy Mode :
Redundancy Configuration : Input Source Line 1, upon redundancy restoration, return
to Line 1
AC Power Lines
Status : Ok
Location : AC Power Line 1
AC Present : Power Present
Active Source : Active
Status : Ok
Location : AC Power Line 2
AC Present : Power Present
Active Source : Not Active
Server Administrator reports values for the Redundancy Status and Redundancy Mode fields.
omreport Viewing System Status Using The Instrumentation Service
23