CLI Guide
Example for SCSI, SATA,
and ATA controllers
omconfig storage enclosure action=setassettag controller=1 enclosure=2
assettag=encl20
Example for SAS
controllers
omconfig storage enclosure action=setassettag controller=1 enclosure=1:2
assettag=encl20
Omconfig Set Enclosure Asset Name
Table 200. Omconfig Set Enclosure Asset Name
Description Specifies the asset name for an enclosure.
Syntax
omconfig storage enclosure action=setassetname controller=id
enclosure=<ENCLOSUREID> assetname=<string>, where id is the controller ID. The
<ENCLOSUREID> variable specifies the enclosure.
In this syntax, <string> is a user-specified alphanumeric string.
Example to Specify the asset name to encl43 for the enclosure attached to connector 2 on controller 1.
Example for SCSI, SATA,
and ATA controllers
omconfig storage enclosure action=setassetname controller=1 enclosure=2
assetname=encl43
Example for SAS
controllers
omconfig storage enclosure action=setassetname controller=1 enclosure=1:2
assetname=encl43
Omconfig Set Temperature Probe Thresholds
Table 201. Omconfig Set Temperature Probe Thresholds
Description Sets the minimum and maximum warning temperature thresholds for a specified temperature probe.
NOTE: This command is not supported on SAS controllers.
Syntax
omconfig storage enclosure action=settempprobes controller=id
enclosure=<ENCLOSUREID> index=id minwarn=n maxwarn=n, where id is the controller ID
and the temperature probe ID. The
<ENCLOSUREID> variable specifies the enclosure.
In this syntax, n is a user-specified alphanumeric string.
Example to Set the temperature probe thresholds to 10 and 40 degree Celsius.
Example for SCSI, SATA,
and ATA controllers
omconfig storage enclosure action=settempprobes controller=1 enclosure=2
index=3 minwarn=10 maxwarn=40
NOTE: Here, temperature probe 3 resides in the enclosure attached to connector 2 on
controller 1.
Omconfig Reset Temperature Probe Thresholds
Table 202. omconfig Reset Temperature Probe Thresholds
Description Resets the minimum and maximum warning temperature thresholds back to their default values.
NOTE: This command is not supported on SAS controllers.
Syntax
omconfig storage enclosure action=resettempprobes controller=id
enclosure=<ENCLOSUREID> index=id, where id is the controller ID and the temperature probe
ID. The
<ENCLOSUREID> variable specifies the enclosure.
168 Omconfig storage commands