CLI Guide
Example
omconfig storage vdisk action=deletevdisk controller=1 vdisk=4
Omconfig reconfiguring virtual disks
Table 145. omconfig reconfiguring virtual disks
Description Reconfigure a virtual disk to change the virtual disk’s RAID level or increase its size by either adding
physical disks or using the available free space. On some controllers, you can also remove physical disks.
NOTE: If you want to reconfigure with an extra physical disk, the physical disk must be of
the supported bus protocol, media type, sector size, T10 Protection Information capability,
and encryption capability.
Syntax
omconfig storage vdisk action=reconfigure controller=id vdisk=id raid=<c|
r0| r1| r1c| r5| r6| r10> pdisk=<PDISK> [size=<size>
vdcapacityexpansion=yes sizeinpercent=<1 to 100>], where id is the controller ID and
virtual disk ID as reported by the omreport command.
NOTE: When you perform the virtual disk reconfiguration operation using the
sizeinpercent/vdcapacityexpansion argument, Storage Management does not allow
addition of physical disks to the existing reconfigured disk group. On successful operation,
the virtual disk capacity is expanded, but the additional physical disk is not considered.
NOTE: To obtain these values, type omreport storage controller to display the
controller IDs and then type omreport storage vdisk controller=ID to display the
IDs for the virtual disks attached to the controller.
Example to Reconfigure virtual disk 4 to a size of 800 MB, use RAID-5 and physical disks 0 through 3 on connector 0
of controller 1. On a SAS controller, the physical disks reside in enclosure 2.
Example for SCSI, SATA,
and ATA controllers
omconfig storage vdisk action=reconfigure controller=1 vdisk=4 raid=r5
size=800m pdisk=0:0:0,0:1:1,0:2:0,0:3:2
Example for SAS
controllers
omconfig storage vdisk action=reconfigure controller=1 vdisk=4 raid=r5
pdisk=0:2:0,0:2:1,0:2:2,0:2:3
Example to Increase the size of the virtual disk by 20 percent using the available free space, use RAID-5 and physical
disks 0 through 3 on connector 0 of controller 1. On a SAS controller, the physical disks reside in
enclosure 2.
Example
omconfig storage vdisk action=reconfigure controller=1 vdisk=4 raid=r5
pdisk=0:2:0,0:2:1,0:2:2,0:2:3 vdcapacityexpansion=yes sizeinpercent=20
NOTE: The vdcapacityexpansion parameter is supported only on PERC H700 and PERC
H800 controllers. If you set vdcapacityexpansion=yes, specify sizeinpercent. If you
do not set
vdcapacityexpansion, specify size.
NOTE: The sizeinpercent parameter is not supported on PERC S130 controller.
Omconfig Secure Virtual Disk
Table 146. omconfig Secure Virtual Disk
Description Encrypts a virtual disk.
Syntax omconfig storage vdisk action=securevd controller=id vdisk=id, where id is the
controller ID and virtual disk ID as reported by the omreport command.
148 Omconfig storage commands