CLI Guide

Omreport EMM Status
The following table describes the syntax for the omreport EMM commands:
NOTE: The status of the EMMs is displayed as degraded if there is a mismatch between the EMM firmware.
Table 100. Omreport EMM Commands
Required Command Levels (1, 2, 3) and
name=value pair
Optional name=value pairs Use
omreport storage enclosure Displays property information for all
enclosures attached to the system.
controller=id enclosure=<ENCLOSUREID>
info=emms where id is the controller
number and ENCLOSUREID is the enclosure
number. For example: controller=0
enclosure=2
Displays the enclosure management
modules (EMMs) for the specified
enclosure.
controller=id enclosure=<ENCLOSUREID>
info=emms index=n where id is the
controller number and ENCLOSUREID is the
enclosure number and n is the number of an
EMM. For example: controller=0
enclosure=2 info=emms index=1
Displays the specified EMMs.
Omreport Enclosure Slot Occupancy Report
The following table describes the syntax for the omreport Enclosure Slot Occupancy Report commands:
Table 101. Omreport Enclosure Slot Occupancy Report Commands
Required Command Levels (1, 2, 3) and
name=value pair
Optional name=value pairs Use
omreport storage enclosure Displays property information for all
enclosures attached to the system.
controller=id enclosure=<ENCLOSUREID>
info=pdslotreport, where id is the controller
number and ENCLOSUREID is the enclosure
number. For example: controller=0
enclosure=2
Displays the empty and occupied slot details
for the specified enclosure.
NOTE: This command is not
supported on Backplane, SCSI, and
SWRAID controllers.
NOTE: On MX5016s, the slot
occupancy displays for empty slots
and unmapped slots as empty slots
for computes MX740c and MX840c.
Omreport Battery Status
The following table describes the syntax for the omreport Battery commands:
Table 102. omreport Battery Commands
Required Command Levels (1, 2, 3) Optional name=value pairs Use
omreport storage battery Displays all batteries present on all
controllers on the system (Some controllers
do not have batteries).
controller=id, where id is the controller
number. For example: controller=0
Displays the battery on the specified
controller.
Omreport storage commands 129