CLI Guide
name=value pair Description
type=log Configures events for logs.
type=memory Configures events for memory.
type=powersupplies Configures events for power supplies.
type=redundancy Configures events for redundancy.
type=systempower Configures events for system power.
type=temps Configures events for temperatures.
type=volts Configures events for voltages.
type=systempeakpower Configures events for system peak power.
type=removableflashmedia Configures events for removable flash media.
Severity
In the context of configuring events, severity determines how severe an event is, before Server Administrator notifies you of the event for
a component type. When there are multiple components of the same type in the same system chassis, you can specify whether you want
notification for event severity according to the number of the component by using the index=<
n> parameter. The following table displays
the valid severity parameters.
Table 73. System Event Severity Parameters
Command Result Description
omconfig system events type=<component
name> severity=info or omconfig
servermodule events type=<component
name> severity=info
Enables notification for informational,
warning, and critical events.
Least restrictive form of event notification.
omconfig system events type=<component
name> severity=warning or omconfig
servermodule events type=<component
name> severity=warning
Enables notification for warning and critical
events.
Omits informational event notification, for
example, when a component returns to
normal status.
omconfig system events type=<component
name> severity=critical or omconfig
servermodule events type=<component
name> severity=critical
Enables notification for critical events only. Restrictive form of event notification.
omconfig system events type=<component
name> severity=none or omconfig
servermodule events type=<component
name> severity=none
Disables event notification. No event notification.
Index
Index refers to the number of an event for a particular component. Index is an optional parameter. When you omit the index parameter,
events are configured for all components of the specified type, such as all fans. For example, when a system contains more than one fan,
you can enable or disable event notification for a particular fan. An example command is as follows:
omconfig system events type=fan index=0 severity=critical
or
omconfig servermodule events type=fan index=0 severity=critical
As a result of the example command, Server Administrator sends an SNMP trap only when the first fan in the system chassis (index 0)
has reached critical fan RPMs.
108