Users Guide

NOTE: Some temperature probe fields differ according to the type of firmware your system has such as BMC or ESM.
Some threshold values are not editable on BMC-based systems. When assigning probe threshold values, Server
Administrator sometimes rounds the minimum or maximum values you enter to the closest assignable value.
Alert Management
Subtabs: Alert Actions | SNMP Traps
Under the Alert Management tab, you can:
View the current alert actions settings and set the alert actions that you want to be performed in the event that a temperature probe
returns a warning or failure value.
View the current SNMP trap alert thresholds and set the alert threshold levels for temperature probes. The selected traps are
triggered if the system generates a corresponding event at the selected severity level.
NOTE: You can set minimum and maximum temperature probe threshold values for an external chassis to whole
numbers only. If you attempt to set either the minimum or maximum temperature probe threshold value to a number
that contains a decimal, only the whole number before the decimal place is saved as the threshold setting.
Voltages
Click the Voltages object to manage voltage levels in your system. Server Administrator monitors voltages across critical components in
various chassis locations in the monitored system. The Voltages object action window can have the following tabs, depending on the
user's group privileges:
Properties and Alert Management.
Properties
Subtab: Voltage Probes
Under the Properties tab, you can view the current readings and status of your system's voltage probes and configure minimum and
maximum values for voltage probe warning threshold.
NOTE:
Some voltage probe fields differ according to the type of firmware your system has, such as BMC or ESM. Some
threshold values are not editable on BMC-based systems.
Alert Management
Subtabs: Alert Actions | SNMP Traps
Under the Alert Management tab, you can:
View the current alert actions settings and set the alert actions that you want to be performed in case a system voltage sensor returns
a warning or failure value.
View the current SNMP trap alert thresholds and set the alert threshold levels for voltage sensors. The selected traps are triggered if
the system generates a corresponding event at the selected severity level.
Software
Click the Software object to view detailed version information about the managed system's essential software components, such as the
operating system and the systems management software. The Software object action window has the following tab, depending on the
user's group privileges:
Properties.
Subtab: Summary
Properties
Under the Properties tab, you can view a summary of the monitored system's operating system and system management software.
Operating system
Click the Operating System object to view basic information about your operating system. The operating system object action window
has the following tab, depending on the user's group privileges: Properties.
Properties
Subtab: Information
Under the Properties tab, you can view basic information about your operating system.
Storage
Server Administrator provides the Storage Management Service:
Server Administrator services
47