Release Notes
• If a new certificate imported to Server Administrator is not active after restarting the Web server, restore the previous certificate. To
restore the previous certificate, do the following:
1. Stop the Web server.
2. Perform one of the following as applicable:
• On systems running Windows:
•
Delete the file keystore.db at <installed directory>\Dell\SysMgt\apache- tomcat\conf\
• Rename the file keystore.db.bak at <installed directory>\Dell\SysMgt\apache- tomcat\conf\ to
keystore.db
• On systems running Linux:
• • Delete the keystore.db file at /opt/dell/srvadmin/lib64/openmanage/apache- tomcat/conf
• Rename the keystore.db.bak at /opt/dell/srvadmin/lib64/openmanage/apache-tomcat/conf to
keystore.db
3. Start the Web server.
• BITS078118: On 12th generation of PowerEdge servers with specific versions of iDRAC, you cannot set the platform event alert
actions (reboot, shut down, and so on) through Server Administrator. Set the alert actions for the events through iDRAC GUI.
• BITS144583: On Mozilla Firefox 21 or later, the Quit browser option does not work after logging out from Server Administrator. To
close the browser or tab, you must manually close the Firefox browser tab.
• BITS177670: On Chrome 38 or later, the Quit browser option does not work after logging out from Server Administrator. To close the
browser or tab, you must manually close the Firefox browser tab.
• On PowerEdge T430, C4130, and R220 II, with PERC S130 configuration and no backplane, Storage Management displays a mock
backplane which does not support the blink/unblink operation for disks available on this configuration.
• BITS256932: The default factory IP for an IDRAC is “192.168.0.120” or “192.168.0.*”, which indicates that the iDRAC IP is not
configured by the user. However, if you choose to configure the default factory IP (static or DHCP) as your iDRAC IP, then the “Not
Configured” value for “iDRAC Network Settings” displayed on the OMSA “System Summary” page can be ignored. Note: On rack and
tower systems, the default factory IP for iDRAC is “192.168.0.120”. On modular systems, the default factory IP range for iDRAC is
“192.168.0.*”, where “*” can be any value from 0 to 255.
• BITS265922: The DSM SA Connection will fail to start if Java Runtime Engine 1.8.0 or newer is installed and specified as the “System
JRE” in Preferences of the Server Administrator web GUI. OMSA 8.3 and older is currently not compatible with Java 1.8 or newer. To
recover to the default Bundled JRE setting so that the web service starts again, enter the following command line: omconfig
preferences webserver attribute=setjre jreversion=bundled
• BITS260330/BITS260451:Restart the data manager service, after Intel NIC driver update or NVIDIA graphics driver update is
performed.
• JIT-60691: In SCOM – Server Management Pack (MP) for monitoring Physical and Team network interfaces XML files are created
due to the heavy usage of the Server Administrator CLI NIC command (omreport chassis nic -fmt xml).
• JIT-112708: Memory critical error not clearing from OMSA even after replacing the DIMM and clearing SEL logs.
If a dual-inline memory module (DIMM) generates errors, memory states of the DIMM’s are not automatically cleared even after the
failing DIMM in that slot is replaced. The command to clear the memory error is dcicfg command=clearmemfailures. The
binary dcicfg, needed to launch the command from a shell command, is included in the OpenManage Server Administrator (OMSA)
suite.
• JIT-120336: Due to some memory error or warning, DIMM health also changes from Normal to Critical or Warning state. However, the
same state is not retained on subsequent Data Manager service restart or system reboot.
• JIT-120571: Server Administrator is not logging ‘NVDIMM not responding’ as critical event in the Alert log. However, the status of the
Non-Volatile memory (NVDIMM) is updated appropriately. Also, an additional generic NVDIMM critical event is generated along with
any NVDIMM critical event.
• JIT-127015: On Server Administrator, the Network Card NetXtreme BCM5720 4-port Gigabit Ethernet PCIe will display as NetXtreme
BCM5720 2-port Gigabit Ethernet PCIe on both CLI and GUI.
• JIT-123355: On modifying the Dell GPG key ( RPM-GPG-KEY ), the Server Administrator installer prompts for importing the Dell GPG
key and continues the installation with warning messages.
• JIT-131581: Open Manage Server Administrator Services will be unresponsive when Integrated Remote Access Controller (iDRAC) is
rebooting or when Reset to Default is in progress.
• JIT-138876: On Server Administrator, an OEM Diagnostic Event Alert log (Event ID 1014) displays the severity as warning. However
the Hardware log displays for the same event as informational.
• JIT-139238: On Server Administrator, an OEM Diagnostic Event Alert log (Event ID 1014) displays incorrect Date and Time of action in
alert log page.
• JIT-146034: After an iDRAC firmware update, on Server Administrator the motherboard and power supply details may not been
displayed on the FRU page. Restarting of the Server Administrator services is recommended in such cases.
Dell EMC OpenManage Release Notes Version 9.3.2