Release Notes
• JIT-106970:After change controller mode operation is performed, two alerts that are generated have the same alert ID and
description.
• If the controller name is not displayed in the alert message, check the controller information for mapping the controller ID and
controller name.
• JIT-106295: Critical and warning a lert is not displayed on Enhanced Event Message alert for Physical Device and Controller ID on
Available Spare threshold.
• JIT-103891: Duplicate alerts for power supply removal are displayed while enclosure power supply cable is removed.
• JIT-103962: The Storage Management displays the removal and insertion alerts intermittently on EMM for HBA controllers during
physical drive hot-plug-out and hot-plug-in.
• JIT-104973: On enhanced mode, an alert is displayed as A Device is inserted in the enclosure for both Power unit and FAN inserted
into enclosure. The message does not state the specific device inserted.
• JIT-97106: You cannot create a partial RAID50 or a RAID60 virtual disk from IDRAC/HII. When the Foreign configuration drives are
imported on the first RAID50 or RAID60 virtual disk with physical drive that is created on Storage Management.
• JIT-103150: On PowerEdge R940XA with dual backplane, the Storage tree does not display the Enclosure ID intermittently during
insertion or removal of multiple drives.
Workaround: Restart the Data-Manager service to resolve this discrepancy.
• JIT-94890: For fully populated chassis, the Storage Management system takes few minutes to load the storage components.
• JIT-101739: If an EMM is removed from MX5016s sled, EMM failure or removal alert is not observed on Server Administrator alerts.
• JIT-109008: Storage Management is enumerating more than one backplane that is not connected to SWRAID controller under
SWRAID controller (S140) on PowerEdge R740xd2 system.
• JIT-98675: On Server Administrator page, a delay is observed on hot-pluggable devices when hot-plugged in or out on HBA 330
MMZ.
• JIT-117535: On the Web Server the Command Line Interface commands does not display the correct exit codes for all sub-queries
when Server Administrator services is not running.
• JIT-110132: When the enclosure is hot plug-in to the 12GBPS HBA controller observes an additional physical disk id in alert log page.
• JIT-109207: Server Administrator displays incorrect capacity information of the drive when formatted with 4096 block size.
• JIT-108887: The alert log displays a message as XML not well-formed after a server restart and post controller mode change
operation intermittently.
Work-around: Clear Logs and restart the service.
• JIT-113370: RAID 10 virtual disk creation using intelligent mirroring fails, as the support is not available from this release of
OpenManage.
• JIT-117535 : On the Web Server the Command Line Interface commands does not display the correct exit codes for all subqueries
when Server Administrator services is not running.
• JIT-110132 : When the enclosure is hot plug-in to the 12GBPS HBA controller observes an additional physical disk id in alert log page.
• JIT-112768 : On systems running Suse Linux Enterprise 15.0 operating system the device protocol of Intel NVMe P4800x devices
displays NVMe 0.0 instead of NVMe 1.0.
• JIT-113370 : RAID 10 virtual disk creation using intelligent mirroring fails, as the support is not available from this release of
OpenManage.
• JIT-113374: While creation of R10, R50 and R60 virtual disks the Storage Management does not display the dedicated hot-spare
suggestions for all disks, if the user selects different size of physical disks as part of virtual disk creation.
Work around: Dedicated hot-spare can be assigned after creation of virtual disk using assign or unassign dedicated hot-spare option.
• JIT-111625 and JIT-112746: In a maximum configuration setup i.e. eight enclosures connected to PERC H840 controller, performing
creating or deleting virtual disk operation multiple times with more than 160 plus physical drives on systems running ESXi operating
system.We observe core or virtual disk creation failure.
Work around: Restart sfcbd service.
• JIT-108887: On Storage Management, observes intermittently malformed alert log showing “XML Data generated for the selection
made is not well formed” on systems running ESXi operating system.
Work around: Restart sfcbd service.
• JIT-119082 : On multipath mode, if clear redundant path option is performed immediately after removing the enclosure cable, few
minutes of delay is observed on Server Administrator GUI to refresh.
Recommendation : It is recommended to wait for the Redundant path broken alerts before performing the clear redundant path. If in
case Server Administrator page delay is observed, wait for few minutes to return to the normal state page or restart the service.
Dell EMC OpenManage Release Notes Version 9.3.2
17