Release Notes
• Depending on your network and proxy configurations and whether you are using Mozilla browser, you may need to enter the exact IP
address of the RAC controller, you are trying to access in the No Proxy for field of your browser.
Perform the following steps:
1. Open your Mozilla browser.
2. Click Edit.
3. Click Preferences.
4. Click Advanced in the left sidebar.
5. Click Proxies in the left sidebar.
6. Enter the RAC IP address in the No Proxy for: field.
7. Click OK and then close the browser.
• To view the RAC Web-based interface when using Mozilla 1.6, you must configure your cookie settings to Enable all cookies.
• To enable all cookies, go to the menu options and click Edit > Preferences > Privacy & Security > Cookies, and then select Enable
all cookies. If you do not perform these steps, you cannot log on to the Web interface and a message appears indicating that your
username and password are incorrect.
• DF384362: Redundancy Status displays as Not Applicable in ESXi even when NICs are teamed. On VMware ESXi systems, NIC
teaming status may not display up in the Server Administrator network section. This is an expected behavior due to the operating
system limitation and has no functional impact to the system.
• DF384061: Self-signed certificate does not enable the compatibility listener in Windows 2008 R2 managed node. On a Windows 2008
R2 managed node, a valid CA signed certificate is required to create compatibility mode WinRM Listener. You cannot create a
compatibility mode listener with a self-signed certificate.
• DF380725: On Internet Explorer or Firefox Web browsers, you cannot attach files to an e- mail if the filename contains non-ASCII
letters. To attach files to an e-mail, rename files to contain ASCII characters.
• On 12th generation of PowerEdge servers, Server Administrator displays the Embedded Systems Management (ESM) or hardware
logs. However, when the maximum limit for number of logs that can be recorded is reached, the existing oldest logs are overwritten.
But for 11th generation of PowerEdge servers or prior, when the maximum limit is reached, the information logging is stopped.
• DF523827: On Citrix XenServer 6.0 or later, if the Alert on Console alert action is configured from the Server Administrator CLI or
GUI, the alert message may not be displayed in a readable format.
• BITS113585: Server Administrator does not log CPU or CMOS Battery Probe Alerts and does not send SNMP traps.
• To resolve this issue, stop the USB arbitration service and run the Inventory Collector. To stop the USB arbitration service:
1. Run the ps aux|grep usb command to check if the USB arbitration service is running.
2. Run the chkconfig usbarbitrator off command to prevent the USB arbitration service from starting during boot.
3. After the USB arbitrator service is stopped, reboot the server to allow the Inventory collector to run.
• DF520449: On all versions of the ESX, the following USB connection error messages are generated. These messages can be ignored.
The following is a typical message:
Table 1. USB connection error message
Vendor: iDRAC Model: MAS022 Rev: 1.00
Type: Direct-Access ANSI SCSI revision: 02
Table 2. USB connection error message
Vendor: iDRAC Model: SECUPD Rev: 0329
Type: Direct-Access ANSI SCSI revision: 02
• DF531509: The setup and/or system password configuration from the Server Administrator GUI or CLI is successful, but the
password is displayed as blank instead of asterisk (*) on the F2 BIOS page.
• DF532055: From Windows Server 2008 R2 SP1, when an administrator manages Red Hat Enterprise Linux 6.1 (64-bit) or 5.7 (32 and
64-bit) operating systems, Server Administrator reports connection error intermittently.
Workaround: Perform the following and manage the remote system from the web server.
1. Configure TCP Chimney offload to disable state by running the following command: netsh int tcp set global chimney=disabled
2. Configure RSS (Receive Side Scaling) to disable state by running the following command: netsh int tcp set global rss=disabled
3. Configure NetDMA to disable state by running the following command: netsh int tcp set global NetDMA=disabled
• BITS086423: After an upgrade to the current version, Server Administrator does not retain the support link information on the
Preferences page.
• BITS091830: Distributed Web Server (DWS) connection does not work if you have installed the sblim-sfcb rpm from SLES11 SP3
operating system DVD. To make the connection work, install sblim-sfcb rpm either from SLES11 SP2 or from OM DVD.
• BITS040184: User in IDRAC user authentication page showing operator privilege(IDRAC user privileges) is displayed as Custom in
Server Administrator.
Dell EMC OpenManage Release Notes Version 9.3.2
11