Connectivity Guide
Table 1703. Battery Charge Count
Name
batteryChargeCount
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.7
Description The number of charges that have been applied to the battery.
Syntax Integer
Access Read-only
Table 1704. Battery Max Charge Count
Name
batteryMaxChargeCount
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.8
Description The maximum number of charges that can be applied to the battery.
Syntax Integer
Access Read-only
Table 1705. Battery Nexus ID
Name
batteryNexusID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.9
Description Durable unique ID for this EMM.
Syntax DisplayString
Access Read-only
Table 1706. Battery Predicted Capacity
Name
batteryPredictedCapacity
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.10
Description Displays the battery's ability to be charged.
Possible values:
1: Failed - The battery cannot be charged and needs to be replaced.
2: Ready - The battery can be charged to full capacity.
4: Unknown - The battery is completing a Learn cycle. The charge capacity of the battery
cannot be determined until the Learn cycle is complete.
Syntax Integer
Access Read-only
Table 1707. Battery Next Learn Time
Name
batteryNextLearnTime
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.11
Description Indicates the time (in hours) the next learn cycle must be executed
Syntax Integer
Access Read-only
Table 1708. Battery Learn State
Name
batteryLearnState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.12
Description Specifies the learn state activity of the battery.
356 Storage Management Group