Users Guide
• Enable Serial Over LAN
• Baud Rate
• Minimum Privilege Required
5. Click Apply Changes.
6. Click Advanced Settings to further configure BMC.
7. In the Serial Over LAN Configuration Advanced Settings window, you may configure the following information:
• Character Accumulate Interval
• Character Send Threshold
8. Click Apply Changes.
9. Click Go Back to Serial Over LAN Configuration to return to the Serial Over LAN Configuration window.
Additional Configuration For iDRAC
To configure the IPv4 and IPv6 properties using the Additional Configuration tab:
1. Click the Modular Enclosure→ System/Server Module → Main System Chassis/Main System→ Remote Access object
2. Click the Configuration tab.
3. Click Additional Configuration.
4. Configure the IPv4 and IPv6 properties as Enabled or Disabled.
5. Click Apply Changes.
NOTE: For information about license management, see the
Dell License Manager User’s Guide
available at
dell.com/openmanagemanuals.
Configuring Remote Access Device Users
To configure Remote Access Device users using the Remote Access page:
1. Click the Modular Enclosure > System/Server Module > Main System Chassis/Main System > Remote Access object.
2. Click the Users tab.
The Remote Access Users window displays information about users that can be configured as BMC/iDRAC users.
3. Click User ID to configure a new or existing BMC/iDRAC user.
The Remote Access User Configuration window allows you to configure a specific BMC/iDRAC user.
4. Specify the following general information:
• Select Enable User to enable the user.
• Enter the name for the user in the User Name field.
• Select the Change Password check box.
• Enter a new password in the New Password field.
• Re-enter the new password in the Confirm New Password field.
5. Specify the following user privileges:
• Select the maximum LAN user privilege level limit.
• Select the maximum serial port user privilege granted.
6. Specify the User group for DRAC/iDRAC user privileges.
7. Click Apply Changes to save changes.
8. Click Back to Remote Access User Window to go back to the Remote Access Users window.
NOTE:
Six additional user entries are configurable when DRAC is installed. This results in a total of 16 users. The
same username and password rules apply to BMC/iDRAC and RAC users. When DRAC/iDRAC6 is installed, all the 16
users entries are allocated to DRAC.
Setting Platform Event Filter Alerts
To configure the most relevant BMC features, such as Platform Event Filter (PEF) parameters and alert destinations using Server
Administrator Instrumentation Service:
56
Working with remote access controller