Release Notes
• JIT-97151: Full view of Physical Disk Page in Server Administrator GUI, the negotiated speed for a 6Gbps drive capable speed is
intermittently shown as 12Gbps.
• JIT-94842: Storage Management carries SHA1 signed library ( storelibIR) in the current release.
• JIT-91317: The storage management displays an incorrect alert "The Patrol Read corrected a media error" instead of
Patrol read completion alert "Media Patrol completed" on BOSS card.
• JIT-97199: In storage management, VDs created on MX5016s through PERC H745X take approximately 1 minute to conrm the
creation to the user.
• JIT-104975: In storage management, FAN speed changes will not update dynamically.
Workaround: Data manager service restart will update the latest FAN speed.
• JIT-106970:After change controller mode operation is performed, two alerts that are generated have the same alert ID and description.
• If the controller name is not displayed in the alert message, check the controller information for mapping the controller ID and controller
name.
• JIT-106295: Critical and warning a lert is not displayed on Enhanced Event Message alert for Physical Device and Controller ID on
Available Spare threshold.
• JIT-103891: Duplicate alerts for power supply removal are displayed while enclosure power supply cable is removed.
• JIT-103962: The Storage Management displays the removal and insertion alerts intermittently on EMM for HBA controllers during
physical drive hot-plug-out and hot-plug-in.
• JIT-104973: On enhanced mode, an alert is displayed as A Device is inserted in the enclosure for both Power unit and FAN inserted into
enclosure. The message does not state the specic device inserted.
• JIT-106603: On PowerEdge MX740c and MX840c, the sfcb core observes intermittently while I/O stress is taking place on VSAN
which is created using MX5016s drives on systems running VMware Sphere ESXi 6.7 operating system.
• JIT-97106: You cannot create a partial RAID50 or a RAID60 virtual disk from IDRAC/HII. When the Foreign conguration drives are
imported on the rst RAID50 or RAID60 virtual disk with physical drive that is created on Storage Management.
• JIT-103150: On PowerEdge R940XA with dual backplane, the Storage tree does not display the Enclosure ID intermittently during
insertion or removal of multiple drives.
Workaround: Restart the Data-Manager service to resolve this discrepancy.
• JIT-94890: For fully populated chassis, the Storage Management system takes few minutes to load the storage components.
• JIT-101739: If an EMM is removed from MX5016s sled, EMM failure or removal alert is not observed on Server Administrator alerts.
• JIT-108571: Unable to display the dynamic hot-plug of enclosure with SAS 12 Gbps intermittently.
Workaround: Restart the service, or reconnect the enclosure.
• JIT-90125: In Server Administrator while conguring the enclosure asset tag and name with maximum length , Server Administrator
displays all the characters completely. But in iDRAC GUI, enclosure asset tag displays the last character as truncated.
• JIT-109008: Storage Management is enumerating more than one backplane that is not connected to SWRAID controller under SWRAID
controller (S140) on PowerEdge R740xd2 system.
• JIT-108897: When maximum number of creations of virtual disk is reached in Storage Management, clearing the foreign conguration
can be done only through system prompt.
• JIT-109094, JIT-108567: A delay of 10-15 minutes is observed initially for displaying Storage Management tree when degraded
MX5016s or enclosure is present. The issue is observed only with HBA controllers like 12 GBPS HBA and HBA330 MMZ.
• JIT-108844: On Enhanced HBA mode, the controller displays for Manage Foreign Conguration operation both the online virtual disks
and foreign virtual disks.
• JIT-108887: The alert log displays a message as XML not well-formed after a server restart and post controller mode change operation
intermittently.
Work-around: Clear Logs and restart the service.
• JIT-105004: The Physical attributes of SATA HDDs is not displayed when hotplugged into a system containing Dell FD33xD HBA or
12Gbps controllers.
Dell EMC OpenManage Release Notes
Version 9.2.1
17