Release Notes
• JIT-61216 : Unable to create virtual disks (Raid 0, 1, 5) using Advanced Wizard if NVME add in card is present
Description: In PERC S140 advanced wizard, virtual disk creation fails if a combination of NVMe and HHHL addin cards(AIC) are
present.
This issue is observed if the PCI slot ID of the add-in card (AIC) matches with the NVMe drive slot number. However, if only NVMe
drives are used, you can successfully create the virtual disks. This is because the GUI code is unable to dierentiate the slot ID/number
in Create Virtual Disks Advanced Wizard.
NOTE: This issue does not cause any data loss. The RAID-5 on S140 with NVMe drives is not supported.
Solution: To resolve this issue, you can create a virtual disk using the Create Virtual Disks Express Wizard and OM-CLI.
• JIT-63561 : In Dell’s 14th generation of PowerEdge servers, while doing the "Reconguration" operation, "Auto Congure RAID0" option
is listed in OMSA under H730P controller's "Available tasks". It happens during RAID level migration from RAID1 to RAID0.
• JIT-71918: On 14th generation of PowerEdge servers when connected with two SAS 12Gbps controllers in Slot4 & Slot5 and each
controllers are connected with separate MD1400 enclosure, both Enclosure EMMs are listed under “Connector 0” and no device is
listed under “Connector 1 ”. Slot-4 SAS 12Gbps controller is connected with two redundant EMMs which are listed in “Connector 0”.
Slot-5 12Gbps controller is also connected with two redundant EMMs, but both are listed under “Connector 0”.
• JIT-71919: On 14th generation of PowerEdge servers when connected with two SAS 12Gbps controller in Slot4 & Slot5 and each
controllers are connected with separate MD1400 enclosure, with two redundant cable i.e. EMM0 & EMM1, then with redundant EMM
both enclosures are listed for EMM0 & EMM1, but physical disks are not displayed for EMM1. Slot-4 SAS 12Gbps controller is
connected with two redundant EMMs – Here both EMMs are listed under “Connector 0”, and for EMM0 physical Disk is listed and for
EMM1 no physical disks are listed. Slot-5 SAS 12Gbps controller is connected with single EMM (ie.EMM1) – Here one EMM0 is listed
under “Connector 0”, and for EMM1 physical Disk are listed.
• JIT-78857 : Successful Prepare to remove and reinsertion operation on a drive for 3-4 times, will result in all the drives getting removed
and inserted back in ESXi 6.5 U1 operating system.
• JIT-79925 : On 13th generation of PowerEdge servers, OMSS reports for PCIe Link Speed is negotiated and maximum link speed/width
shows '0' for Slot 1 device.
• JIT-76259: EMMI alert description for Dedicated hot spare assigned physical disk should contain meaningful alert description instead of
the statement, This alert is provided for informational purposes.
• JIT-72304 : Able to assign lesser capacity physical disk as a DHS to the virtual disk created with physical disk having higher capacity.
• JIT-80079: If Prepare to remove operation is executed on a Non-RAID PCIe-SSD physical disk, the bus protocol for the virtual disk
associated with that physical disk, changes to SATA from PCIe-SSD.
• JIT-80085 : The alert descriptions, in the online help, for Set Available Spare Warning Threshold and Set Available Spare Critical
Threshold show The Available Spare Warning Threshold for PCIe SSDs is set to %1 and The Available Spare Critical Threshold for
PCIe SSDs is set to %1 respectively, instead of The Available Spare Warning Threshold for PCIe SSDs is set to <value> and The
Available Spare Critical Threshold for PCIe SSDs is set to <value>.
• JIT-94666: For Non-RAID drives attached to SWRAID controller enumerates for virtual Disk layout as Non-RAID. Whereas on Storage
Management GUI, when you click on virtual disk name the physical drives does not display as Non-RAID.”
• JIT-96484: Auto Cong RAID 0 task fails and displays improper error message, when there are no free drives to create RAID 0 virtual
disks on the server. Exit the wizard of the error page as Server Administrator log out.
Workaround: Once again login to OMSA GUI.
• JIT-95176: The Physical disks available in MX5016s connected to MX7000 chassis slot 8 does not support RAID-10 intelligent mirror
virtual disk creation.
• JIT-92467: The dynamic mapping of an enclosure for the rst time also displays the unmapped enclosure for a short period. Refresh
the Server Administrator page to remove the unmapped enclosure entries.
• JIT-93304: Virtual disk created using compute backplane and MX5016s drives, is hot-plug removed and then inserted back into the
chassis. When foreign cong operations are executed immediately after the hot-plug operation, the Server Administrator GUI hangs for
2 minutes.
This does not occur if the same foreign cong operations are executed after sometime post MX5016s hot-plug.
• JIT-97092: Dynamic mapping of MX5016s on H745pMX controller displays the status as unknown. Upon, performing the service
restart the status is reected correctly.
16
Dell EMC OpenManage Release Notes
Version 9.2.1