BITS050574: On 11th generation and 12th generation of PowerEdge servers running the Linux OS, the omreport system summary
command displays RAC Command Interface as 7.1.0. "RAC Command Interface" is a DRAC4 RPM and its version is 7.1. It is installed as
a dependent package for iDRAC6 and iDRAC7 Command Interface packages.
If a new certicate imported to Server Administrator is not active after restarting the Web server, restore the previous certicate. To
restore the previous certicate, do the following:
a Stop the Web server.
b Perform one of the following as applicable:
On systems running Windows:
Delete the le keystore.db at <installed directory>\Dell\SysMgt\apache- tomcat\conf\
Rename the le keystore.db.bak at <installed directory>\Dell\SysMgt\apache- tomcat\conf\ to keystore.db
On systems running Linux:
Delete the keystore.db le at /opt/dell/srvadmin/lib64/openmanage/apache- tomcat/conf
Rename the keystore.db.bak at /opt/dell/srvadmin/lib64/openmanage/apache-tomcat/conf to keystore.db
c Start the Web server.
BITS078118: On 12th generation of PowerEdge servers with specic versions of iDRAC, you cannot set the platform event alert actions
(reboot, shut down, and so on) through Server Administrator. Set the alert actions for the events through iDRAC GUI.
BITS144583: On Mozilla Firefox 21 or later, the Quit browser option does not work after logging out from Server Administrator. To
close the browser or tab, you must manually close the Firefox browser tab.
BITS177670: On Chrome 38 or later, the Quit browser option does not work after logging out from Server Administrator. To close the
browser or tab, you must manually close the Firefox browser tab.
On PowerEdge T430, C4130, and R220 II, with PERC S130 conguration and no backplane, Storage Management displays a mock
backplane which does not support the blink/unblink operation for disks available on this conguration.
BITS256932: The default factory IP for an IDRAC is “192.168.0.120” or “192.168.0.*”, which indicates that the iDRAC IP is not congured
by the user. However, if you choose to congure the default factory IP (static or DHCP) as your iDRAC IP, then the “Not Congured”
value for “iDRAC Network Settings” displayed on the OMSA “System Summary” page can be ignored. Note: On rack and tower
systems, the default factory IP for iDRAC is “192.168.0.120. On modular systems, the default factory IP range for iDRAC is “192.168.0.*”,
where “*” can be any value from 0 to 255.
BITS265922: The DSM SA Connection will fail to start if Java Runtime Engine 1.8.0 or newer is installed and specied as the “System
JRE” in Preferences of the Server Administrator web GUI. OMSA 8.3 and older is currently not compatible with Java 1.8 or newer. To
recover to the default Bundled JRE setting so that the web service starts again, enter the following command line: omcong
preferences webserver attribute=setjre jreversion=bundled
BITS260330/BITS260451:Restart the data manager service, after Intel NIC driver update or NVIDIA graphics driver update is
performed.
JIT-25314: The alert log is not generated in Server Administrator, when the Power Supply Unit (PSU) is inserted in the server without
connecting a power cable for that PSU. However, corresponding log is generated in ESM or Hardware logs.
JIT-22805: Server Administrator does not recommend the upgrade to major versions of JRE. For more details, see the release notes of
Server Administrator (packaged with Server Administrator application) or at dell.com/openmanagemanuals. All the Internet browsers
required TLS1.1 or higher version to connect to Server Administrator web application. Please refer the vendor (Microsoft, Mozillla,
Google) browser congurations for setting the TLS versions.
JIT-26671 - On Server Administrator, the Duplex capability value is displayed as “Unknown” in Broadcom Extreme E-Series Network
interface card in the NIC properties.
JIT-60297 - On RedHat Enterprise Linux 7.3, after performing ASR operation; restart the system once it recovers from ASR operation.
Then navigate to Server Administrator Logs page in GUI. You could see an XML error. This could be due to xml log les being corrupted.
To Recover: Perform clear logs operation so that new logs would be generated. Before performing this operation, if needed please take
back up of old xml log les.
JIT-69735 - The Server Administrator web application blocks the client connections in the Internet browser settings with TLSv1.0
version and lesser.
JIT-60691: In SCOM – Server Management Pack (MP) for monitoring Physical and Team network interfaces XML les are created due
to the heavy usage of the Server Administrator CLI NIC command (omreport chassis nic -fmt xml).
JIT-36610/JIT-36599: In OpenManage Server Administrator slots page, the Dell “HBA330 Adapter” PERC card will be enumerated as
“12GB/s HBA internal” and Dell “HBA330 Mini” PERC card will be enumerated as “SAS3008 PCI-Express Fusion-MPT SAS-3
JIT-81661: On 14G PowerEdge servers, the embedded cache devices are incorrectly displayed as a Field Replaceable Unit (FRU). These
embedded cache devices are not FRU's