Dell EMC OpenManage SNMP Reference Guide Version 9.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2017 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents 1 Introduction....................................................................................................................................................7 What’s New in this release................................................................................................................................................ 7 Supported SNMP Versions...............................................................................................................................................
Thermal Group................................................................................................................................................................ 129 Thermal Group Tables.............................................................................................................................................. 129 Thermal Group Variable Values...............................................................................................................................
Array Disk Enclosure Connection Table................................................................................................................. 397 Array Disk Channel Connection Table................................................................................................................... 399 Fan Table....................................................................................................................................................................401 Fan Connection Table.....
7 Standard Data Type Definitions.................................................................................................................. 472 Common Data Types..................................................................................................................................................... 472 Variables with Data Types of State Capabilities and State Capabilities Unique..................................................... 472 Dell Status Data Types.................................
1 Introduction This reference guide provides information about the Simple Network Management Protocol (SNMP) Management Information Base (MIB) which is applicable for Dell EMC OpenManage. NOTE: This guide contains information that may also be applicable to earlier OpenManage supported platforms. This introduction is divided into two sections. The first section, Introduction to SNMP Reference Guide, explains the SNMP Reference Guide design.
• New enumeration added: Device Group Variable Values: Processor Device family: DellProcessorDeviceFamily: deviceFamilyIsAMDZen Supported SNMP Versions Table 1. Supported SNMP Versions Operating System Supported OMSA SNMP version Windows SNMP v1 Linux SNMP v1 Managed Object Used in This Document The MIB is divided into several major groups. The following table provides information about the MIB names, name of the agent that uses each MIB and the purpose: Table 2.
Server Administrator Instrumentation MIB The Server Administrator Instrumentation MIB ( filename 10892.mib ) provides instrumentation data that allows you to monitor the health of a system with SNMP management applications.
Section Topics MIB Group Numbers 16 BIOS Setup Control Group — defines variables for BIOS functions such as boot sequence, speakers, Wake on the local area network (LAN), diskettes, ports, and network interface controllers (NIC) 1400 17 Local Response Agent Group — defines variables for global settings and actions.
Section Topics MIB Group Numbers NA 1 27 Storage Management Alert Reference — lets you monitor the health of storage resources such as controllers, connectors, array disks, and virtual disks NA Server Administrator Field Replaceable Unit MIB The Server Administrator Field Replaceable Unit MIB (filename dcs3fru.mib) provides information about field replaceable unit (FRU) hardware that may be present in your system.
Frequently Used Terms in Variable Names The following terms are frequently used in the name of a MIB variable: Capability refers to the actions an object can perform, or to actions that can be taken by the object. Hot-pluggable is an example of a capability. If a card is hot-pluggable, it can be replaced while a system is running. Capability settings refer to the capabilities of the object that the user can select from and activate if desired.
Table 8. UUID Table Entry Name uUIDTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.20.1 Description Defines the UUID table entry. Syntax UUIDTableEntry Access Not accessible Index uUIDIndex , uUIDchassisIndex Table 9. UUID Chassis Index Name uUIDchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 10. UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.
Access Read-only Read-only Section Organization Sections in this reference guide are based on the Server Administrator MIBs, so the complexity of each section depends on the complexity of each MIB group. The first section provides a high-level introduction to the MIB group. If the group is defined by one or more tables, the second section lists these tables. The third section documents the variables that comprise the group, and if applicable, the variables that comprise the tables.
• Data type of the variable (for example: integer, string, octet string) • Whether the variable is accessible, not accessible, or read-only • Index or indexes, if applicable For each MIB group that has unique variable definitions, tables are included in the last section of the section to explain the meaning of the terms. Standards for writing MIBs are defined by the Internet Engineering Task Force (IETF).
Table 13. ROOT CCITT(0) ISO(1) ORG(3) DOD(6) INTERNET(1) MGMT(2) MIB(1) EXPERIMENTAL( 3) PRIVATE(4) ENTERPRISES(1) DELL (674) SNMPv2(6) In the preceding example, the OID prefix for the Dell enterprise would be 1.3.6.1.4.1.674. The numbers in boldface type show the categories and numbers that apply to Server Administrator. All Server Administrator-defined OIDs consist of 1.3.6.1.4.1.674 followed by additional component values. SNMP Security SNMP version 1 has a very limited security mechanism.
Two drawbacks to SNMP traps are that they are sent using UDP, which is not a guaranteed delivery mechanism, and that they are not acknowledged by the receiver. An SNMP trap message contains the trap’s enterprise OID, the agent IP address, a generic trap ID, the specific trap ID, a time stamp, and zero or more variable bindings (varbinds). The combination of an enterprise OID and a specific trap ID uniquely identifies each Server Administrator-defined trap.
2 Server Administrator Group The Server Administrator group comprises of the following sections: • Instrumentation MIB Version Group • Systems Management Software Group • System State Group • Chassis Information Group • Operating System Group • System Resource Group • Power Group • Thermal Group • Remote Flash BIOS Group • Port Group • Device Group • Slot Group • Memory Group • BIOS Setup Control Group • Local Response Agent Group • Cost of Ownership Group • Cluster Group •
• Cluster Group • Baseboard Management Controller Group • Field Replaceable Unit Group Instrumentation MIB Version Group The Instrumentation Management Information Base (MIB) Version Group defines the attributes that identify the version of the Instrumentation MIB supported by the systems management software.
Description Defines the maintenance version number for the version of this MIB supported by the systems management software. For example, if the MIB version is 1.2.3, the maintenance version number is 3. Syntax DellUnsigned8BitRange Access Read-only Systems Management Software Group The Systems Management Software Group allows users to see information about the standards and software that are supported by the agent of a particular managed computer chassis.
Table 19. Systems Management Software Build Number Name systemManagementSoftwareBuildNumber Object ID 1.3.6.1.4.1.674.10892.1.100.3 Description Defines the build number of the systems management software. Syntax DellUnsigned16BitRange Access Read-only Table 20. Systems Management Software Description Name Name systemManagementSoftwareDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.100.4 Description Defines the description of the systems management software.
Table 24. Systems Management Software URL Name Name systemManagementSoftwareURLName Object ID 1.3.6.1.4.1.674.10892.1.100.8 Description Defines the universal resource locator (URL) of the systems management software. Syntax DisplayString (SIZE (0..1024)) Access Read-only Table 25. Systems Management Software Language Name Name systemManagementSoftwareLanguageName Object ID 1.3.6.1.4.1.674.10892.1.100.9 Description Defines the language of the systems management software.
Table 29. Systems Management Software Manufacturer Name Name systemManagementSoftwareManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.100.13 Description Defines the manufacturer of the systems management software. Syntax DellString Access Read-only Systems Management Software Variable Values This section includes definitions of server administrator-specific variable values used in this section. Table 30.
System State Group The Management Information Base (MIB) variables presented in this section enable you to track various attributes that describe the state of the critical components supported by your system. Components monitored under the System State Group include power supplies, AC power cords, AC power switches, and cooling devices, as well as temperature, fan, amperage, and voltage probes. System State Group Table The System State Group defines objects in the System State MIB table.
List 2 Variables that provide health status of each component in associated subsystem in chassis: • systemStatePowerSupplyStatusDetails • systemStateVoltageStatusDetails • systemStateAmperageStatusDetails • systemStateCoolingDeviceStatusDetails • systemStateTemperatureStatusDetails • systemStateMemoryDeviceStatusDetails • systemStateChassisIntrusionStatusDetails • systemStateACPowerCordStatusDetails • systemStatePowerUnitStatusList • systemStateCoolingUnitStatusList • systemStateACPower
Table 35. System State Chassis Index Name systemStatechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 36. System State Global System Status Name systemStateGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.2 Description Defines the global system status of all chassis being monitored by this instrumentation instance. Syntax DellStatus Access Read-only Table 37.
Access Read-only Table 40. System State Power Unit Status Redundancy Name systemStatePowerUnitStatusRedundancy Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.6 Description Defines the system status of the power unit(s) in this chassis. Syntax DellStatus Access Read-only Table 41. System State Power Unit Status Details Name systemStatePowerUnitStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.7 Description Defines the status of all power units in this chassis.
Table 44. System State Power Supply Status Details Name systemStatePowerSupplyStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.10 Description Defines the status of all power supplies in this chassis. The results are returned as a binary octet string, Each byte of the octet string represents the status of a specific power supply. The first byte returned represents the status of the first power supply, the second byte returned represents the status of the second power supply, and so on.
Table 48. System State Amperage State Details Name systemStateAmperageStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.14 Description Defines the state of all current probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific current probe. The first byte returned represents the state of the first current probe, the second byte returned represents the state of the second current probe, and so on.
Table 52. System State Cooling Unit Status Redundancy Name systemStateCoolingUnitStatusRedundancy Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.18 Description Defines the state of all cooling units in this chassis. Syntax DellStatusRedundancy Access Read-only Table 53. System State Cooling Unit State Details Name systemStateCoolingUnitstateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.19 Description Defines the state of all cooling units in this chassis.
Table 56. System State Cooling Device Status Details Name systemStateCoolingDeviceStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.22 Description Defines the status of all cooling devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific cooling device.
Table 60. System State Memory Device State Details Name systemStateMemoryDeviceStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.26 Description Defines the state of all memory devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of the specific memory device. The first byte returned represents the state of the first memory device, the second byte returned represents the status of the second memory device, and so on.
Table 64. System State Chassis Intrusion Status Combined Name systemStateChassisIntrusionStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.30 Description Defines the intrusion status of all intrusion detection devices in this chassis. The result is returned as a combined status value. The value has the same definition type as DellStatus. Syntax DellStatus Access Read-only Table 65. System State Chassis Intrusion Status Details Name systemStateChassisIntrusionStatusDetails Object ID 1.3.
Description Defines the individual status of all AC power switches in this chassis. The first byte returned represents the status of the first AC power switch, the second byte returned represents the status of the second AC power switch, and so on. Syntax Octet String Access Read-only Table 69. System State AC Power Cord State Details Name systemStateACPowerCordStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
Access Read-only Table 73. System State Redundant Memory Unit Status Redundancy Name systemStateRedundantMemoryUnitStatusRedundancy Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.39 Description Defines the overall redundancy status for redundant memory. Syntax DellStatusRedundancy Access Read-only Table 74. System State Redundant Memory Unit Status Details Name systemStateRedundantMemoryUnitStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
Description Lists the status of each power unit of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a power unit. The first byte returned represents the status of the first power unit, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String Access Read-only Table 78. System State Cooling Unit Status Combined Name systemStateCoolingUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
Access Read-only Table 82. System State Redundant Memory Unit Status Combined Name systemStateRedundantMemoryUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.48 Description Defines the combined status of all redundant memory units of this chassis. Syntax DellStatus Access Read-only Table 83. System State Redundant Memory Unit Status List Name systemStateRedundantMemoryUnitStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
Table 86. System State Battery Status Combined Name systemStateBatteryStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.52 Description Defines the combined status of all batteries of this chassis. Syntax DellStatus Access Read-only Table 87. System State Battery Status List Name systemStateBatteryStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.53 Description Lists the status of each battery of this chassis.
Syntax DellStatus Access Read-only Table 91. System State SD Card Device Status List Name systemStateSDCardDeviceStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.57 Description Lists the status of each SD Card device of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a SD Card device. The first byte returned represents the status of the first SD Card device, and so on.
Table 93. Chassis Information Table Entry Name chassisInformationTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.10.1 Description Defines the chassis information table entry. Syntax ChassisInformationTableEntry Access Not accessible Index chassisIndexChassisInformation Table 94. Chassis Index Chassis Information Name chassisIndexChassisInformation Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.1 Description Defines the index (one-based) of this chassis. The first chassis is numbered one.
Table 98. Chassis Parent Index Reference Name chassisparentIndexReference Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4 Description Defines the index (one-based) of the parent chassis of this chassis, if any. A zero (0) means that this chassis is the parent of all other chassis managed by the Server Administrator. Syntax DellObjectRange Access Read-only Table 99. Chassis Type Name chassisType Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.6 Description Defines the chassis type.
Table 103. Chassis Asset Tag Name Name chassisAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.10 Description Defines the user-assigned asset tag name for this chassis. Syntax DisplayString Access Read-only Table 104. Chassis Service Tag Name Name chassisServiceTagName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.11 Description Defines the service tag name for this chassis. Syntax DisplayString Access Read-only Table 105. Chassis ID Name chassisID Object ID 1.3.6.1.4.1.674.10892.
Table 108. Chassis System Name Name chassisSystemName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.15 Description Defines the system name of this chassis. Syntax DellString Access Read-only Table 109. Chassis System Boot Date Name Name chassisSystemBootDateName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.16 Description Defines the boot time of this system. Syntax DellDateName Access Read-only Table 110. Chassis System Date Name Name chassisSystemDateName Object ID 1.3.6.1.4.1.674.10892.
Table 113. Chassis System User Phone Number Name Name chassisSystemUserPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.20 Description Defines the user-assigned phone number of the primary user of the system. Syntax DellString Access Read-only Table 114. Chassis Connection Status Unique Name chassisConnectionStatusUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.21 Description Defines the status of the connection from the system chassis to an expansion chassis.
Table 118. Chassis LED Control Settings Unique Name chassisLEDControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.25 Description Defines the readings and settings of the LED control hardware in the chassis. Syntax DellLEDControlSettings (See Front-Panel LED Control Settings) Access Read-only Table 119. Chassis Hard-Drive (HD) Fault Clear Control Capabilities Name chassisHDFaultClearControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Table 123. Chassis Lock Present Name chassisLockPresent Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.30 Description Specifies whether a chassis lock is present on the chassis. Syntax DellBoolean Access Read-only Table 124. Chassis Host Control Capabilities Unique Name chassishostControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.31 Description Defines the capabilities of the host control object.
Table 128. Chassis Watchdog Control Expiry Time Capabilities Unique Name chassiswatchDogControlExpiryTimeCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.35 Description Defines the capabilities of the watchdog expiry timer object. Syntax DellWatchDogTimerCapabilities (See Watchdog Timer Capabilities) Access Read-only Table 129. Chassis Watchdog Control Expiry Time Name chassiswatchDogControlExpiryTime Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Table 133. Chassis Reseller Name Name chassisResellerName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.40 Description Defines the name of the chassis reseller. Syntax DisplayString Access Read-only Table 134. Chassis Reseller Contact Information Name Name chassisResellerContactInformationName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.41 Description Defines the chassis reseller contact information name. Syntax DisplayString Access Read-only Table 135.
Table 138. Chassis NMI Button Control Settings Unique Name chassisNMIButtonControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.45 Description Defines the current reading and allows setting of the NMI button control hardware. Syntax DellNMIButtonControlSettings (See NMI Button Control Settings) Access Read-only Table 139. Chassis System Properties Name chassisSystemProperties Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.46 Description Defines the properties of the system.
Table 143. Chassis Node ID Name chassisNodeIDName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.50 Description Defines the NodeID of the chassis. Syntax DellString Access Read-only UUID Table These objects comprise the server administrator definitions for the Universal Unique Identifier (UUID). Table 144. UUID Table Name uUIDTable Object ID 1.3.6.1.4.1.674.10892.1.300.20 Description Defines the UUID table. Syntax SEQUENCE OF UUIDTableEntry Access Not accessible Table 145.
Table 147. UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.2 Description Defines the index of the UUID in a specified chassis. Syntax DellObjectRange Access Read-only Table 148. UUID Type Name uUIDType Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3 Description Defines the type of the UUID for this chassis. Syntax DellUUIDType Access Read-only Table 149. UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.
Description Defines the POST Log Table entry. Syntax PostLogTableEntry Access Not accessible Index postLogchassisIndex , postLogRecordIndex Table 152. POST Log Chassis Index Name postLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 153. POST Log Record Index Name postLogRecordIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.
Table 156. POST Log Record Name postLogRecord Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5 Description Defines the data for the specified chassis and record index in the POST log being returned. Syntax DisplayString (SIZE (0..1024)) Access Read-only Table 157. POST Log Format Name postLogFormat Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5 Description Defines format of the POST log. Syntax DellLogFormat (See Log Format) Access Read-only Event Log Table Table 158.
Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 161. Event Log Record Index Name eventLogRecordIndex Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.2 Description Defines the record index of the event log. Syntax DellUnsigned32BitRange Access Read-only Table 162. Event Log State Capabilities Unique Name eventLogStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.
Syntax DellLogFormat (See Log Format) Access Read-only Table 166. Event Log Severity Status Name eventLogSeverityStatus Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.7 Description Defines the severity of the event log record. Syntax DellStatus Access Read-only Status Mandatory Table 167. Event Log Date Name Name eventLogDateName Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.8 Description Defines the date and time of the event log record.
, systemBIOSIndex Table 170. System BIOS Chassis Index Name systemBIOSchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 171. System BIOS Index Name systemBIOSIndex Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.2 Description Defines the index (one-based) of the system BIOS of this object. Syntax DellObjectRange Access Read-only Table 172.
Access Read-only Table 175. System BIOS Size Name systemBIOSSize Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.6 Description Defines the image size of the system BIOS in kilobytes (KB). A zero (0) indicates that the image size of the BIOS is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 176. System BIOS Release Date Name Name systemBIOSReleaseDateName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.7 Description Defines the release date of the system BIOS.
Syntax DellUnsigned64BitRange Access Read-only Table 180. System BIOS Manufacturer Name Name systemBIOSManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.11 Description Defines the system BIOS manufacturer’s name. Syntax DellString Access Read-only Table 181. System BIOS Characteristics Name systemBIOSCharacteristics Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.12 Description Defines characteristics of the system BIOS.
• • • • • • • • • • • • • • • Syntax Bit 24 - Int 13h - 3.5 in / 720 KB Floppy Services are supported Bit 25 - Int 13h - 3.5 in / 2.
Access Read-only Firmware Table Table 184. Firmware Table Name firmwareTable Object ID 1.3.6.1.4.1.674.10892.1.300.60 Description Defines the Firmware Table. Syntax SEQUENCE OF FirmwareTableEntry Access Not accessible Table 185. Firmware Table Entry Name firmwareTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.60.1 Description Defines the Firmware Table entry Syntax FirmwareTableEntry Access Not accessible Index firmwarechassisIndex , firmwareIndex Table 186.
Description Defines the capabilities of the firmware states. Syntax DellStateCapabilities Access Read-only Table 189. Firmware State Capabilities Name firmwareStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.4 Description Defines the state of the firmware and allows for the setting of the firmware. Syntax DellStateCapabilities Access Read-only Table 190. Firmware Status Name firmwareStatus Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.
Access Read-only Table 194. Firmware Update Capabilities Name firmwareUpdateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.9 Description Defines the bitmap of supported methods for firmware update. Syntax DellUnsigned16BitRange Access Read-only Table 195. Firmware Date Name Name firmwareDateName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.10 Description Defines the date of the firmware. Syntax DellDateName Access Read-only Table 196.
Syntax IntrusionTableEntry Access Not accessible Index intrusionchassisIndex , intrusionIndex Table 199. Intrusion Chassis Index Name intrusionchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 200. Intrusion Index Name intrusionIndex Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.2 Description Defines the index of the intrusion objects in this subgroup.
Syntax DellStatus Access Read-only Table 204. Intrusion Reading Name intrusionReading Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.6 Description Defines the reading of the intrusion object. Syntax DellIntrusionReading Access Read-only Table 205. Intrusion Type Name intrusionType Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.7 Description Defines the type of the intrusion object. Syntax DellIntrusionType Access Read-only Table 206.
Syntax BaseBoardTableEntry Access Not accessible Index baseBoardChassisIndex , baseBoardIndex Table 209. Baseboard Chassis Index Name baseBoardchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 210. Baseboard Index Name baseBoardIndex Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.2 Description Defines the index (one-based) of the base board.
Syntax DellStatus Access Read-only Table 214. Baseboard Feature Flags Name baseBoardFeatureFlags Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.6 Description Defines the features of the baseboard.. Syntax DellBaseBoardFeatureFlags Access Read-only Table 215. Baseboard Type Name baseBoardType Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.7 Description Defines the type of the baseboard. Syntax DellBaseBoardType Access Read-only Table 216.
Table 219. Baseboard Product Name Name baseBoardProductName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.11 Description Defines the baseboard product’s name. Syntax DellString Access Read-only Table 220. Baseboard Version Name Name baseBoardVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.12 Description Defines the baseboard version name.. Syntax DellString Access Read-only Table 221. Baseboard Service Tag Name Name baseBoardServiceTagName Object ID 1.3.6.1.4.1.674.10892.1.300.80.
Table 224. Baseboard Express Service Code Name Name baseBoardExpressServiceCodeName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.16 Description Defines the express service code of the baseboard. Syntax DellString Access Read-only Chassis Information Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 225.
spaceSaving(15) The chassis type is a spacesaver. lunchBox(16) The chassis type is a lunch box. mainSystemChassis(17 The chassis type is the main system chassis. ) expansionChassis(18) The chassis type is an expansion chassis. subChassis(19) The chassis type is a subchassis. busExpansionChassis( The chassis type is a bus-expansion chassis. 20) peripheralChassis(21 The chassis type is a peripheral chassis. ) raidChassis(22) The chassis type is a disk RAID chassis.
unknown(1) The LED control capabilities are unknown. alertOnErrorCapable( The LED control can be set to alert on an error condition. 2) alertOnWarningAndErr The LED control can be set to alert on an error and a orCap able(4) warning condition. alertOnWarningOrErro The LED control can be set to alert on an error or a warning rCapa ble(6) condition. Table 230.
resetAndEnable(10) The hard-drive fault LEDs have been reset and enabled. Table 233. Chassis Identification Control Capabilities Variable Name : DellChassisIdentifyControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The LEDs do not have any chassis identification capabilities. unknownCapabilities( The chassis identification control’s capabilities are unknown.
manualPowerOFFCapabl The operator can power off capable host. e(2) manualPowerCycleCapa The operator can power-cycle capable host. ble(4) manualAllExceptOpera The operator can reboot and power off capable host. ting SystemShutdownCapabl e(7) manualOperatingSyste The operator can shut down the operating-system– mShut downCapable(8) shutdown capable host. manualFullyCapable(1 The operator can reboot, power on and off the power-cycle 5) capable host, and shut down the operating-system– shutdown capable host.
Table 237. Watchdog Control Capabilities Variable Name : DellWatchDogControlCapabilities NOTE: When the system determines that the operating system is not responding, it automatically performs the selected action without operator intervention. Data Type: Integer Possible Data Values Meaning of Data Value automaticRebootCapab Watchdog controls can be set to reboot capable host. le(1) automaticPowerCycleC Watchdog controls can be set to power cycleable capable apable(2) host.
type1Capable(1) Watchdog timer can time in intervals from 20–480 seconds. type2Capable(2) Watchdog timer can time in 30-, 60-, 120-, and 480-second intervals. type3Capable(4) Watchdog timer can time in 60-second intervals. Table 240. Power Button Control Capabilities Variable Name : DellPowerButtonControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The power button has no capabilities. unknownCapabilities( The power button capabilities are unknown.
Possible Data Values Meaning of Data Value none(0) No properties. energySmart(1) The system is an Energy Smart System. Table 244. NMI Button Control Settings Variable Name : DellNMIButtonControlSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The NMI button has no settings capabilities. unknown(1) The NMI button settings are unknown. enabled(2) The NMI button state is enabled. disabled(4) The NMI button state is disabled. Table 245.
Data Type: Integer Possible Data Values Meaning of Data Value other(1) The chassis system class is not one of the following: unknown(2) The chassis system class is unknown. workstationClass(3) The chassis system class is a workstation. serverClass(4) The chassis system class is a server. desktopClass(5) The chassis system class is a desktop. portableClass(6) The chassis system class is a portable. netPCClass(7) The chassis system class is a Net PC.
unifiedServerConfigu The firmware type is Unified Server Configurator. rator(19) lifecycleController( The firmware type is Lifecycle Controller. 20) iDRAC7(21) The firmware type is Integrated Dell Remote Access Controller 7. iDRAC8(22) The firmware type is Integrated Dell Remote Access Controller 8. Table 248.
Table 250. Operating System Memory Table Entry Name operatingSystemTableEntry Object ID 1.3.6.1.4.1.674.10892.1.400.20.1 Description Defines the Operating System Memory Table entry. Syntax OperatingSystemMemoryTableEntry Access Not accessible Index operatingSystemMemorychassisIndex Table 251. Operating System Memory Chassis Index Name operatingSystemMemorychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.1 Description Defines the index (one-based) of this chassis.
Table 255. Operating System Memory Total Physical Size NOTE: operatingSystemMemoryTotalPhysicalSize is no more used. This attribute is deprecated and replaced by operatingSystemMemoryExtTotalPhysicalSize. Name operatingSystemMemoryTotalPhysicalSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.5 Description Defines the total physical memory size in kilobytes. Syntax DellUnsigned32BitRange Access Read-only Table 256.
Table 260. Operating System Memory Available Virtual Size Name operatingSystemMemoryAvailableVirtualSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.10 Description Defines the available virtual memory size in kilobytes. Syntax DellUnsigned32BitRange Access Read-only Table 261. Operating System Memory Ext Total Physical Size NOTE: This attribute replaces operatingSystemMemoryTotalPhysicalSize. Name operatingSystemMemoryExtTotalPhysicalSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.
Table 263. System Resource Map Table Entry Name systemResourceMapTableEntry Object ID 1.3.6.1.4.1.674.10892.1.500.10.1 Description Defines the System Resource Map Table entry. Syntax SystemResourceMapTableEntry Access Not accessible Index systemResourceMapchassisIndex , systemResourceMapIndex Table 264. System Resource Map Chassis Index Name systemResourceMapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.1 Description Defines the index (one-based) of this chassis.
Table 268. System Resource Map Status Name systemResourceMapStatus Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.5 Description Defines the status of this system map. Syntax DellStatus Access Read-only Table 269. System Resource Map Type Name systemResourceMapType Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.6 Description Defines the type of this system map. Syntax DellSystemResourceMapType (System Resource Map Type) Access Read-only System Resource Owner Table Table 270.
Syntax DellObjectRange Access Read-only Table 273. System Resource Owner Index Name systemResourceOwnerIndex Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.2 Description Defines the index of system resource owners for this chassis. Syntax DellObjectRange Access Read-only Table 274. System Resource Owner State Capabilities Name systemResourceOwnerStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.3 Description Defines the capabilities of this system resource owner.
Table 278. System Resource Map Index Reference Name systemResourceMapIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.7 Description Defines the index to the associated system resource map in this chassis. Syntax DellObjectRange Access Read-only Table 279. System Resource Owner Description Name Name systemResourceOwnerDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.8 Description Defines the description name of the system resource owner.
, systemResourceIOPortIndex Table 283. System Resource I/O Port Chassis Index Name systemResourceIOPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 284. System Resource I/O Port Index Name systemResourceIOPortIndex Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.2 Description Defines the index (one-based) of the system resource I/O ports in this chassis.
Table 288. System Resource I/O Port Owner Index Reference Name systemResourceIOPortOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.6 Description Defines the index to the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only Table 289. System Resource I/O Port Share Disposition Name systemResourceIOPortShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.7 Description Defines the share disposition of the system resource I/O port.
Table 293. System Resource Memory Table Entry Name systemResourceMemoryTableEntry Object ID 1.3.6.1.4.1.674.10892.1.500.40.1 Description Defines the System Resource Memory Table entry. Syntax SystemResourceMemoryTableEntry Access Not accessible Index systemResourceMemorychassisIndex , systemResourceMemoryIndex Table 294. System Resource Memory Chassis Index Name systemResourceMemorychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.
Table 298. System Resource Memory Status Name systemResourceMemoryStatus Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.5 Description Defines the status of this system resource memory. Syntax DellStatus Access Read-only Table 299. System Resource Memory Owner Index Reference Name systemResourceMemoryOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.6 Description Defines the index to the associated system resource owner in this chassis.
Table 303. System Resource Memory Flags Name systemResourceMemoryFlags Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.10 Description Defines the permission flags for the system resource memory. Syntax DellResourceMemoryFlags (Resource Memory Flags) Access Read-only System Resource Interrupt Table Table 304. System Resource Interrupt Table Name systemResourceInterruptTable Object ID 1.3.6.1.4.1.674.10892.1.500.50 Description Defines the System Resource Interrupt Table.
Syntax DellObjectRange Access Read-only Table 308. System Resource Interrupt State Capabilities Name systemResourceInterruptStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.3 Description Defines the capabilities of this system resource interrupt. Syntax DellStateCapabilities Access Read-only Table 309. System Resource Interrupt State Settings Name systemResourceInterruptStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.
Table 313. System Resource Interrupt Level Name systemResourceInterruptLevel Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.8 Description Defines the interrupt request (IRQ) level of the system resource interrupt. Syntax DellUnsigned32BitRange Access Read-only Table 314. System Resource Interrupt Type Name systemResourceInterruptType Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.9 Description Defines the interrupt type of the system resource interrupt.
, systemResourceDMAIndex Table 318. System Resource DMA Chassis Index Name systemResourceDMAchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 319. System Resource DMA Index Name systemResourceDMAIndex Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.2 Description Defines the index of system resource DMAs in this chassis. Syntax DellObjectRange Access Read-only Table 320.
Table 323. System Resource DMA Owner Index Reference Name systemResourceDMAOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.6 Description Defines the index to the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only Table 324. System Resource DMA Share Disposition Name systemResourceDMAShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.7 Description Defines the share disposition of the system resource DMA.
Table 328. System Resource Map Type Variable Name: DellSystemResourceMapType Data Type: Integer Possible Data Values Meaning of Data Value other(1) The system resource map type is not one of the following: unknown(2) The system resource map type is unknown (not known or not monitored). typeOne(3) The system resource map is type 1 (one). Table 329.
memoryIsWriteOnly(2) The resource memory is write-only. memoryIsPreFetchable(4) The resource memory is prefetchable. memoryIsCombinedWritable(8) The resource memory is read-write. memoryIsF24(16) The resource memory is F24. Table 332. Resource Interrupt Type Variable Name: DellResourceInterruptType Data Type: Integer Possible Data Values Meaning of Data Value interruptIsLevelSensitive(1 ) The interrupt type is level sensitive. interruptIsLatched(2) The interrupt type is latched. Table 333.
dmaTransferWidthIs16Bits(4) The DMA transfer width is 16 bits. dmaTransferWidthIs32Bits(5) The DMA transfer width is 32 bits. dmaTransferWidthIs64Bits(6) The DMA transfer width is 64 bits. dmaTransferWidthIs128Bits(7 ) The DMA transfer width is 128 bits. Power Group The Power Group provides information about power units (a group of power supplies in a system chassis), power supplies, and voltage and amperage probes.
Index powerUnitchassisIndex, powerUnitIndex Table 338. Power Unit Chassis Index Name powerUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 339. Power Unit Index Name powerUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.2 Description Defines the index of the power unit in this chassis. Syntax DellObjectRange Access Read-only Table 340.
Table 343. Power Supply Count for Redundancy Name powerSupplyCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.6 Description Defines the total number of power supplies required for this power unit to have redundancy. Syntax DellString Access Read-only Table 344. Power Unit Name Name powerUnitName Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.7 Description Defines the name of the power unit in this chassis. Syntax DellString Access Read-only Table 345.
Table 348. Power Supply Chassis Index Name powerSupplychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 349. Power Supply Index Name powerSupplyIndex Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.2 Description Defines the index of power supply. Syntax DellObjectRange Access Read-only Table 350.
Table 353. Power Supply Output Watts Name powerSupplyOutputWatts Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.6 Description Defines the maximum sustained output wattage of the power supply in tenths of watts. Syntax DellSigned32BitRange Access Read-only Table 354. Power Supply Type Name powerSupplyType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.7 Description Defines the type of power supply. Syntax DellPowerSupplyType (Power Supply Type Definitions) Access Read-only Table 355.
Table 358. Power Supply Sensor State Name powerSupplySensorState Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.11 Description Defines the state reported by the power supply sensor, and supplements the state and settings of the power supply. Syntax DellPowerSupplySensorState (Power Supply Sensor State) Access Read-only Table 359. Power Supply Configuration Error Type Name powerSupplyConfigurationErrorType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.
Table 363. Power Supply Current Input Voltage Name powerSupplyCurrentInputVoltage Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.16 Description This attribute defines the current input voltage to the power supply (in Volts). Syntax DellSigned32BitRange Access Read-only Voltage Probe Table Table 364. Voltage Probe Table Name voltageProbeTable Object ID 1.3.6.1.4.1.674.10892.1.600.20 Description Defines the Voltage Probe Table. Syntax VoltageProbeTableEntry Access Not accessible Table 365.
Table 368. Voltage Probe State Capabilities Name voltageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.3 Description Defines the capabilities of the voltage probe. Syntax DellStateCapabilities Access Read-only Table 369. Voltage Probe State Settings Name voltageProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.4 Description Defines the state and settings of the voltage probe. Syntax DellStateSettings Access Read-only Table 370.
Table 373. Voltage Probe Location Name Name voltageProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.8 Description Defines the location of the voltage probe in this chassis. Syntax DellString Access Read-only Table 374. Voltage Probe Upper Nonrecoverable Threshold Name voltageProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.9 Description Defines the value of the voltage probe’s upper nonrecoverable threshold.
Table 378. Voltage Probe Lower Critical Threshold Name voltageProbeLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.13 Description Defines the value of the voltage probe’s lower critical threshold. Syntax DellSigned32BitRange Access Read-only Table 379. Voltage Probe Lower Nonrecoverable Threshold Name voltageProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.14 Description Defines the value of the voltage probe’s lower nonrecoverable threshold.
Access Not accessible Table 383. Amperage Probe Table Entry Name amperageProbeTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.30.1 Description Defines the Amperage Probe Table entry. Syntax AmperageProbeTableEntry Access Not accessible Index amperageProbechassisIndex , amperageProbeIndex Table 384. Amperage Probe Chassis Index Name amperageProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.1 Description Defines the index (one-based) of this chassis.
Access Read-only Table 388. Amperage Probe Status Name amperageProbeStatus Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.5 Description Defines the status of the amperage probe. Syntax DellSigned32BitRange Access Read-only Table 389. Amperage Probe Reading Name amperageProbeReading Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.6 Description Defines the reading for an amperage probe of type other than amperageProbeTypeIsDiscrete.
Access Read-only Table 392. Amperage Probe Upper Nonrecoverable Threshold Name amperageProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.9 Description Defines the value of the amperage probe’s upper nonrecoverable threshold. The value is an integer representing the amperage in milliamperes that the probe is reading. Syntax DellSigned32BitRange Access Read-only Table 393. Amperage Probe Upper Critical Threshold Name amperageProbeUpperCriticalThreshold Object ID 1.3.
Table 397. Amperage Probe Lower Nonrecoverable Threshold Name amperageProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.14 Description Defines the value of the amperage probe’s lower nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Table 398. Amperage Probe Probe Capabilities Name amperageProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.15 Description Defines the probe capabilities of the amperage probe.
Syntax ACPowerSwitchTableEntry Access Not accessible Index aCPowerSwitchchassisIndex , aCPowerSwitchIndex Table 402. AC Power Switch Chassis Index Name aCPowerSwitchChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.1 Description Defines the index (one-based) of the chassis containing this AC power switch. Syntax DellObjectRange Access Read-only Table 403. AC Power Switch Index Name aCPowerSwitchIndex Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.
Syntax DellStatusRedundancy Access Read-only Table 407. AC Power Cord Count for Redundancy Name aCPowerCordCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.6 Description Defines the total number of AC power cords required for this AC power switch to have redundancy. Syntax DellObjectRange Access Read-only Table 408. AC Power Switch Name Name aCPowerSwitchName Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.7 Description Defines the name of this AC power switch.
Syntax SEQUENCE OF ACPowerCordTableEntry Access Not accessible Table 412. AC Power Cord Table Entry Name aCPowerCordTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.42.1 Description Defines the AC Power Cord Table entry. Syntax ACPowerCordTableEntry Access Not accessible Index aCPowerCordchassisIndex , aCPowerCordIndex Table 413. AC Power Cord Chassis Index Name aCPowerCordChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.
Syntax DellACPowerCordStateSettings Access Read-only Table 417. AC Power Cord Status Name aCPowerCordStatus Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.5 Description Defines the status of this AC power cord. Syntax DellStatus Access Read-only Table 418. AC Power Cord AC Power Switch Index Reference Name aCPowerCordaCPowerSwitchIndexReference Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.6 Description Defines the index (one-based) to the associated AC power switch for this AC power cord.
Access Not accessible Index batteryChassisIndex, batteryIndex Table 422. Battery Chassis Index Name batteryChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.1 Description Defines the index (one-based) of the chassis that contains the battery. Syntax DellObjectRange Access Read-only Table 423. Battery Index Name batteryIndex Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.2 Description Defines the index (one-based) of the battery. Syntax DellObjectRange Access Read-only Table 424.
Table 427. Battery Reading Name batteryReading Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.6 Description Defines the reading of the battery. Syntax DellBatteryReading (Battery Reading) Access Read-only Table 428. Battery Location Name Name batteryLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.7 Description Defines the location of the battery. Syntax DellString Access Read-only Power Usage Table Table 429. Power Usage Table Name powerUsageTable Object ID 1.3.6.1.4.1.674.10892.
Table 432. Power Usage Index Name powerUsageIndex Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.2 Description Defines the index (one-based) of the power usage information. Syntax DellObjectRange Access Read-only Table 433. Power Usage State Capabilities Name powerUsageStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.3 Description Defines the state capabilities of the power usage information. Syntax DellStateCapabilities Access Read-only Table 434.
Table 437. Power Usage Cumulative Wattage Name powerUsageCumulativeWattage Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.7 Description Defines the total wattage used (in Watt-hours) by this entity since the date and time specified by the powerUsageCumulativeWattageStartDateName attribute. Syntax DellUnsigned32BitRange Access Read-only Table 438. Power Usage Cumulative Wattage Start Date Name Name powerUsageCumulativeWattageStartDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
Table 442. Power Usage Peak Amps Name powerUsagePeakAmps Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.12 Description Defines the peak amperage reading (in tenths of Amps) for this entity since the date and time specified by the powerUsagePeakAmpsStartDateName attribute. Syntax DellUnsigned32BitRange Access Read-only Table 443. Power Usage Peak Amps Start Date Name Name powerUsagePeakAmpsStartDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
Table 447. Power Usage Power Cap Capabilities Name powerUsagePowerCapCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.17 Description Defines the system power cap capabilities. Syntax DellPowerCapCapabilities Access Read-only Table 448. Power Usage Power Cap Setting Name powerUsagePowerCapSetting Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.18 Description Defines the system power cap setting. Syntax DellPowerCapSetting Access Read-only Table 449.
Power Profile Table Table 452. Power Profile Table Name powerProfileTable Object ID 1.3.6.1.4.1.674.10892.1.600.70 Description Defines the Power Profile Table. Syntax SEQUENCE OF PowerProfileTableEntry Access Not accessible Table 453. Power Profile Table Entry Name powerProfileTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.70.1 Description Defines the Power Profile Table Entry.
Access Read-only Table 457. Power Profile Setting Name powerProfileSetting Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.4 Description Defines the power profile setting. Syntax DellPowerProfileType Access Read-only Table 458. Power Profile Custom CPU Management Capabilities Name powerProfileCustomCPUManagementCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.5 Description Defines the custom CPU power and performance management capabilities that are available for the Custom power profile.
Access Read-only Table 462. Power Profile Custom Fan Management Capabilities Name powerProfileCustomFanManagementCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.9 Description Defines the custom fan power and performance management capabilities that are available for the Custom power profile. Syntax DellFanPowerPerformanceManagementType Access Read-only Table 463. Power Profile Custom Fan Management Setting Name powerProfileCustomFanManagementSetting Object ID 1.3.6.1.4.1.674.10892.1.
fanFailure(8) The power supply fan has failed. onlineAndFanFailure(10) The power supply is online and indicating that its fan is not working. powerSupplyIsON(16) The power supply is indicating that it is on. powerSupplyIsOk(32) The power supply is indicating that it is OK. acSwitchIsON(64) The power supply is indicating that the AC power switch is on. onlineandAcSwitchIsON (66) The power supply is online and indicating that the AC power supply switch capability is activated.
psACLost(8) The power supply’s AC power is lost. acLostOrOutOfRange(16) The power supply’s AC power is lost or out of range. acOutOfRangeButPresent(32) The power supply’s AC power is present, but it is out of range. configurationError(64) The power supply sensor detects a configuration error. Table 468.
Table 470. Voltage Probe Discrete Reading Variable Name: DellVoltageDiscreteReading Data Type: Integer Possible Data Values Meaning of Data Value voltageIsGood(1) The voltage probe discrete reading is good. voltageIsBad(2) The voltage probe discrete reading is bad. Table 471.
Table 472. Amperage Probe Discrete Reading Variable Name: DellAmperageDiscreteReading Data Type: Integer Possible Data Values Meaning of Data Value amperageIsGood(1) The amperage probe discrete reading is good. amperageIsBad(2) The amperage probe discrete reading is bad. Table 473. AC Power Switch Capabilities Variable Name: DellACPowerSwitchCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknownCapabilities(1) The AC power switch’s capabilities are unknown.
Table 476. AC Power Cord State Capabilities Variable Name: DellACPowerCordStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The AC power cord’s capabilities are unknown. onlineCapable(2) The AC power cord can be disabled (offline) or enabled (online). notReadyCapable(4) The AC power cord’s capabilities are not ready. Table 477.
disable(2) Power cap can be disabled. Table 480. Power Cap Setting Variable Name: DellPowerCapSetting Data Type: Integer Possible Data Values Meaning of Data Value disabled(0) Power cap is disabled. enabled(1) Power cap is enabled. Table 481. Power Profile Type Variable Name: DellPowerProfileType Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) Power profile type is Maximum Performance.
NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) Memory power and performance management type is Maximum Performance. mhz1333(2) Memory power and performance is 1333 MHz. . mhz1067(4) Memory power and performance is 1067 MHz. mhz800(8) Memory power and performance is 800 MHz. minPower(16) Memory power and performance management type is Minimum Power. Table 484.
Description Defines the Cooling Unit Table. Syntax TableEntry Access Not accessible Table 486. Cooling Unit Table Entry Name coolingUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.10.1 Description Defines the Cooling Unit Table entry. Syntax TableEntry Access Not accessible Index coolingUnitchassisIndex , coolingUnitIndex Table 487. Cooling Unit Chassis Index Name coolingUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.
Description Defines the state and settings of the cooling unit. Syntax DellStateSettings Access Read-only Table 491. Cooling Unit Redundancy Status Name coolingUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.5 Description Defines the redundancy status of the cooling unit. Syntax DellStatusRedundancy Access Read-only Table 492. Cooling Device Count For Redundancy Name coolingDeviceCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.
Syntax CoolingDeviceTableEntry Access Not accessible Table 496. Cooling Device Table Entry Name coolingDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.12.1 Description Defines the Cooling Device Table entry. Syntax CoolingDeviceTableEntry Access Not accessible Index cooling DevicechassisIndex , coolingDeviceIndex Table 497. Cooling Device Chassis Index Name coolingDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.
Syntax DellStateSettings Access Read-only Table 501. Cooling Device Status Name coolingDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.5 Description Defines the status of the cooling device. Syntax DellStatusProbe Access Read-only Table 502. Cooling Device Reading Name coolingDeviceReading Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.6 Description Defines either the cooling device’s speed in revolutions per minute (RPM), or the off/on value of the fan.
Description Defines the value of the fan’s upper nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Table 506. Cooling Device Upper Critical Threshold Name coolingDeviceUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.10 Description Defines the value of the fan’s upper critical threshold. Syntax DellSigned32BitRange Access Read-only Table 507. Cooling Device Upper Noncritical Threshold Name coolingDeviceUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.
Access Read-only Table 511. Cooling Device Cooling Unit Index Reference Name coolingDevicecoolingUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.15 Description Defines the index for the associated system cooling unit in this chassis. Syntax DellObjectRange Access Read-only Table 512. Cooling Device Subtype Name coolingDeviceSubType Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.16 Description Defines the cooling device subtype.
Description Defines the Temperature Probe Table. Syntax TemperatureProbeTableEntry Access Not accessible Table 516. Temperature Probe Table Entry Name temperatureProbeTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.20.1 Description Defines the Temperature Probe Table entry. Syntax TemperatureProbeTableEntry Access Not accessible Index temperatureProbechassisIndex , temperatureProbeIndex Table 517. Temperature Probe Chassis Index Name temperatureProbechassisIndex Object ID 1.3.6.1.4.1.
Description Defines the state and settings of the temperature probe. Syntax DellStateSettings Access Read-only Table 521. Temperature Probe Status Name temperatureProbeStatus Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.5 Description Defines the status of the temperature probe in tenths of degrees Celsius. Syntax DellStatusProbe Access Read-only Table 522. Temperature Probe Reading Name temperatureProbeReading Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
Description Defines the value of the temperature probe’s upper nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Table 526. Temperature Probe Upper Critical Threshold Name temperatureProbeUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.10 Description Defines the value of the temperature probe’s upper critical threshold. Syntax DellSigned32BitRange Access Read-only Table 527.
Access Read-only Table 531. Temperature Probe Probe Capabilities Name temperatureProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.15 Description Defines the probe capabilities of the temperature probe. Syntax DellProbeCapabilities Access Read-only Table 532. Temperature Probe Discrete Reading Name temperatureProbeDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.16 Description Defines the reading for a temperature probe of type temperatureProbeTypeIsDiscrete.
Table 534. Cooling Device Subtype Variable Name: DellCoolingDeviceSubType Data Type: Integer Possible Data Values Meaning of Data Value coolingDeviceSubTypeIsOther(1) The cooling device subtype is not one of the following: coolingDeviceSubTypeIsUnknown(2) The cooling device subtype is unknown (not known or not monitored). coolingDeviceSubTypeIsAFanThatReads InRPM(3) The cooling device subtype is a fan that reads in RPMs.
Remote Flash BIOS Group The Remote Flash Basic Input/Output System (BIOS) Table defines the variables used to remotely update the BIOS in a system. The variables also define the capabilities of BIOS updates on the system. Remote Flash BIOS Group Table The Remote Flash BIOS Group defines objects in the Remote Flash BIOS MIB table. Remote Flash BIOS Table The following object sets up the Remote Flash BIOS Table: Table 538. Remote Flash BIOS Table Name remoteFlashBIOSTable Object ID 1.3.6.1.4.1.674.10892.
Description Defines the index to the remote BIOS update hardware on this system. Syntax DellObjectRange Access Read-only Table 542. Remote Flash BIOS State Capabilities Unique Name remoteFlashBIOSStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.3 Description Defines the capabilities of the remote BIOS update hardware on this system. Syntax DellRemoteFlashBIOSStateCapabilitiesUnique (Remote Flash BIOS State Capabilities Unique) Access Read-only Table 543.
Syntax DellRemoteFlashBIOSCompletionCode (Remote Flash BIOS Completion Code) Access Read-only Table 547. Remote Flash BIOS Minimum Contiguous Memory Name remoteFlashBIOSMinimumContiguousMemory Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.8 Description Defines the minimum size of contiguous memory required for remote BIOS update in kilobytes.
Table 550. Remote Flash BIOS Completion Code Variable Name: DellRemoteFlashBIOSCompletionCode Data Type: Integer Possible Data Values Meaning of Data Value completionCodeIsOther(1) The completion code status is not one of the following: completionCodeIsUnknown(2) The completion code is unknown (not known or not monitored). completionCodeIsOK(3) This completion code completed successfully. completionCodeIsBadImage(4) This completion code is a bad flash BIOS image.
Pointing Port Table Table 551. Pointing Port Table Name pointingPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.10 Description Defines the Pointing Port Table. Syntax IntegerPointingPortTableEntry Access Not accessible Table 552. Pointing Port Table Entry Name pointingPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1 Description Defines the Pointing Port Table entry.
Table 555. Pointing Port State Capabilities Name pointingPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.10.3 Description Defines the capabilities of the pointing port. Syntax DellStateCapabilities Access Read-only Table 556. Pointing Port State Settings Name pointingPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.10.4 Description Defines the state and settings of the pointing port. Syntax DellStateSettings Access Read-only Table 557.
Table 560. Pointing Port Name Name pointingPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.10.8 Description Defines the name of the pointing port. Syntax DellString Access Read-only Table 561. Pointing Port BIOS Connector Type Name pointingPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.10.9 Description Defines the basic input/output system (BIOS) connector type of the pointing port. Syntax DellGenericPortConnectorType Access Read-only Keyboard Port Table Table 562.
Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 565. Keyboard Port Index Name keyboardPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.2 Description Defines the index of the keyboard ports in this chassis. Syntax DellObjectRange Access Read-only Table 566. Keyboard Port State Capabilities Name keyboardPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.3 Description Defines the capabilities of the keyboard port.
Syntax DellPortSecurityState Access Read-only Table 570. Keyboard Port Connector Type Name keyboardPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.7 Description Defines the connector type of the keyboard port. Syntax DellKeyboardPortConnectorType (See Keyboard Port Connector Types) Access Read-only Table 571. Keyboard Port Name Name keyboardPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.8 Description Defines the name of the keyboard port.
Description Defines the Processor Port Table entry. Syntax ProcessorPortTableEntry Access Not accessible Index processorPortchassisIndex , processorPortIndex Table 575. Processor Port Chassis Index Name processorPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 576. Processor Port Index Name processorPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.
Table 579. Processor Port Status Name processorPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.5 Description Defines the status of the processor port. Syntax DellStatus Access Read-only Table 580. Processor Port Security State Name processorPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.6 Description Defines the security settings of the processor port. Syntax DellPortSecurityState Access Read-only Table 581.
Memory Device Port Table Table 584. Memory Device Port Table Name memoryDevicePortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.40 Description Defines the Memory Device Port Table. Syntax IntegerMemoryDevicePortTableEntry Access Not accessible Table 585. Memory Device Port Table Entry Name memoryDevicePortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1 Description Defines the Memory Device Port Table entry.
Table 588. Memory Device Port State Capabilities Name memoryDevicePortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.3 Description Defines the capabilities of the memory device port. Syntax DellStateCapabilities Access Read-only Table 589. Memory Device Port State Settings Name memoryDevicePortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.4 Description Defines the state and settings of the memory device port. Syntax DellStateSettings Access Read-only Table 590.
Table 593. Memory Device Port Name Name memoryDevicePortName Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.8 Description Defines the name of the memory device port. Syntax DellString Access Read-only Table 594. Memory Device Port BIOS Connector Type Name memoryDevicePortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.9 Description Defines the BIOS connector type of the memory device port. Syntax DellGenericPortConnectorType Access Read-only Table 595.
Syntax IntegerMonitorPortTableEntry Access Not accessible Table 598. Monitor Port Table Entry Name monitorPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1 Description Defines the Monitor Port Table entry. Syntax MonitorPortTableEntry Access Not accessible Index monitorPortchassisIndex , monitorPortIndex Table 599. Monitor Port Chassis Index Name monitorPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.
Table 602. Monitor Port State Settings Name monitorPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.4 Description Defines the state of the monitor port. Syntax DellStateSettings Access Read-only Table 603. Monitor Port Status Name monitorPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.5 Description Defines the status of the monitor port. Syntax DellStatus Access Read-only Table 604. Monitor Port Security State Name monitorPortSecurityState Object ID 1.3.6.1.4.1.
Table 607. Monitor Port BIOS Connector Type Name monitorPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.9 Description Defines the name of the BIOS connector type of the monitor port. Syntax DellGenericPortConnectorType Access Read-only Small Computer System Interface Port Table Table 608. Small Computer System Interface Port Table Name sCSIPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.60 Description Defines the SCSI Port Table.
Description Defines the index of the SCSI ports in this chassis. Syntax DellObjectRange Access Read-only Table 612. SCSI Port State Capabilities Name sCSIPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.3 Description Defines the capabilities of the SCSI port. Syntax DellStateCapabilities Access Read-only Table 613. SCSI Port State Settings Name DellStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.4 Description Defines the state and settings of the SCSI port.
Syntax DellSCSIPortConnectorType (See SCSI Port Connector Types) Access Read-only Table 617. SCSI Port Name Name sCSIPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.8 Description Defines the name of the SCSI port. Syntax DellString Access Read-only Table 618. SCSI Port BIOS Connector Type Name sCSIPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.9 Description Defines the BIOS connector type of the SCSI port.
Table 621. Parallel Port Chassis Index Name parallelPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 622. Parallel Port Index Name parallelPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.2 Description Defines the index of the parallel ports in this chassis. Syntax DellObjectRange Access Read-only Table 623.
Table 626. Parallel Port Security State Name DellPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.6 Description Defines the security state of the parallel port. Syntax DellStatus Access Read-only Table 627. Parallel Port Connector Type Name parallelPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.7 Description Defines the connector type of the parallel port. Syntax DellParallelPortConnectorType Access Read-only Table 628.
Table 631. Parallel Port Base I/O Address Name parallelPortBaseIOAddress Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.11 Description Defines the Base Input/Output (I/O) address of the parallel port. Syntax DellUnsigned64BitRange Access Read-only Table 632. Parallel Port IRQ Level Name parallelPortIRQLevel Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.12 Description Defines the Interrupt Request Level (IRQ) of the parallel port. Syntax DellUnsigned8BitRange Access Read-only Table 633.
Index serialPortchassisIndex , serialPortIndex Table 636. Serial Port Chassis Index Name serialPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 637. Serial Port Index Name serialPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.2 Description Defines the index of the serial ports in this chassis. Syntax DellObjectRange Access Read-only Table 638.
Syntax DellStatus Access Read-only Table 641. Serial Port Security State Name serialPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.6 Description Defines the security settings of the serial port. Syntax DellPortSecurityState Access Read-only Table 642. Serial Port Connector Type Name serialPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.7 Description Defines connector type of the serial port. Syntax DellSerialPortConnectorType Access Read-only Table 643.
Access Read-only Table 646. Serial Port Base I/O Address Name serialPortBaseIOAddress Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.11 Description Defines the base I/O address of the serial port. Syntax DellUnsigned64BitRange Access Read-only Table 647. Serial Port IRQ Level Name serialPortIRQLevel Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.12 Description Defines the IRQ of the serial port. Syntax DellUnsigned8BitRange Access Read-only Universal Serial Bus Port Table Table 648.
Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 651. USB Port Index Name uSBPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.2 Description Defines the index of the USB ports in this chassis Syntax DellObjectRange Access Read-only Table 652. USB Port State Capabilities Name uSBPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.3 Description Defines the capabilities of the USB port.
Syntax DellPortSecurityState Access Read-only Table 656. USB Port Connector Type Name uSBPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.7 Description Defines the connector type of the USB port. Syntax DellUSBPortConnectorType Access Read-only Table 657. USB Port Name Name uSBPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.8 Description Defines the name of the USB port.
connectorPortTypeIsDB9(9) The pointing port connector type is nine-pin DB-9. connectorPortTypeIsMicroDIN(10) The pointing port connector type is micro Deutsche Industrie Norm (DIN). connectorPortTypeIsAccessBusUSB The pointing port connector type is Access (11) Bus USB. connectorPortTypeIsPC98(12) The port connector type is a PC-98. Table 659.
connectorPortTypeIsSlot2(9) The processor port connector type is a slot two. connectorPortTypeIs370PinSocket(10) The processor port connector type is a 370 pin socket. Table 661. Memory Device Port Connector Types Variable Name : DellMemoryDevicePortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The memory device port connector type is not one of the following: connectorPortTypeIsUnknown(2) The memory device port connector type is unknown.
Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The SCSI port connector type is not one of the following: connectorPortTypeIsUnknown(2) The SCSI port connector type is unknown. connectorPortTypeIsDIN25pin(3) The SCSI port connector type is a DIN 25-pin. connectorPortTypeIsDIN50pin(4) The SCSI port connector type is a DIN 50-pin. connectorPortTypeIsDIN68pin(5) The SCSI port connector type is a DIN 68-pin.
Table 665. Pointing Device Table Entry Name pointingDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1 Description Defines the Pointing Device Table entry. Syntax PointingDeviceTableEntry Access Not accessible Index pointingDevicechassisIndex , pointingDeviceIndex Table 666. Pointing Device Chassis Index Name pointingDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.1 Description Defines the index (one-based) of this chassis.
Table 670. Pointing Device Status Name pointingDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.5 Description Defines the status of the pointing device. Syntax DellStatus Access Read-only Table 671. Pointing Port Index Reference Name pointingPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.6 Description Defines the index to the pointing port in this chassis. Syntax DellObjectRange Access Read-only Table 672.
Table 675. Keyboard Device Table Entry Name keyboardDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1 Description Defines the Keyboard Device Table entry. Syntax KeyboardDeviceTableEntry Access Not accessible Index keyboardDevicechassisIndex , keyboardDeviceIndex Table 676. Keyboard Device Chassis Index Name keyboardDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.1 Description Defines the index (one-based) of this chassis.
Table 680. Keyboard Device Status Name keyboardDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.5 Description Defines the status of the keyboard device. Syntax DellStatus Access Read-only Table 681. Keyboard Port Index Reference Name keyboardPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.6 Description Defines the index to the associated the keyboard port in this chassis. Syntax DellStatus Access Read-only Table 682.
Table 685. Processor Device Table Entry Name processorDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1 Description Defines the Processor Device Table entry. Syntax ProcessorDeviceTableEntry Access Not accessible Index processorDevicechassisIndex , processorDeviceIndex Table 686. Processor Device Chassis Index Name processorDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.1 Description Defines the index (one-based) of this chassis.
Table 690. Processor Device Status Name processorDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.5 Description Defines the status of the processor device. Syntax DellStatus Access Read-only Table 691. Processor Port Index Reference Name processorPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.6 Description Defines the index to the associated processor port in this chassis. Syntax DellObjectRange Access Read-only Table 692.
Table 695. Processor Device Family Name processorDeviceFamily Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.10 Description Defines the family of the processor device. Syntax DellProcessorDeviceFamily (See Processor Device Family) Access Read-only Table 696. Processor Device Maximum Speed Name processorDeviceMaximumSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.11 Description Defines the maximum speed of the processor device in megahertz (MHz). A zero (0) indicates that the speed is unknown.
Table 700. Processor Device Upgrade Information Name processorDeviceUpgradeInformation Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.15 Description Defines the processor upgrade information for the processor device. Syntax DellProcessorUpgradeInformation (See Processor Upgrade Information) Access Read-only Table 701. Processor Device Version Name Name processorDeviceVersionName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.16 Description Defines the version name of the processor device.
Table 705. Processor Device Characteristics Name processorDeviceCharacteristics Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.20 Description This attribute defines characteristics of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one). NOTE: Bits 2-15 need to be examined in the context of bit 1.
Bit Position Meaning if Set Bit 1 Demand-Based Switching (DBS) supported Bit 2 eXecute Disable (XD) supported Bit 3 Hyper-Threading (HT) supported Bit 4 Turbo Mode (TM) supported Syntax DellUnsigned16BitRange Access Read-only Table 708. Processor Device Brand Name Name processorDeviceBrandName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.23 Description Defines the brand of the processor device. Syntax DellString Access Read-only Table 709.
Bit Position Meaning if Set Bit 0 Virtualization Technology (VT) is deprecated Bit 1 Demand-Based Switching (DBS) is deprecated Bit 2 eXecute Disable (XD) is deprecated Bit 3 Hyper-Threading (HT) is deprecated Bit 4 Turbo Mode (TM) is deprecated Syntax DellUnsigned16BitRange Access Read-only Processor Device Status Table Table 712. Processor Device Status Table Name processorDeviceStatusTable Object ID 1.3.6.1.4.1.674.10892.1.1100.
Table 715. Processor Device Status Index Name processorDeviceStatusIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.2 Description Defines the index (one-based) of the processor device status probe. Syntax DellObjectRange Access Read-only Table 716. Processor Device Status State Capabilities Name processorDeviceStatusStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.3 Description Defines the state capabilities of the processor device status probe.
Table 720. Processor Device Status Location Name Name processorDeviceStatusLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.7 Description Defines the location name of the processor device status probe. Syntax DellString Access Read-only Table 721. Processor Device Status Port Index Reference Name processorDeviceStatusPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.8 Description Defines the index (one-based) of the associated processor port in the same chassis.
Syntax DellObjectRange Access Read-only Table 725. Cache Device Index Name cacheDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.2 Description Defines the index of the cache device in this chassis. Syntax DellObjectRange Access Read-only Table 726. Cache Device State Capabilities Name cacheDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.3 Description Description Defines the capabilities of the cache device.
Table 730. Cache Device Type Name cacheDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.7 Description Defines the type of cache device. Syntax DellCacheDeviceType (See Cache Device Type) Access Read-only Table 731. Cache Device Location Name cacheDeviceLocation Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.8 Description Defines the location of the cache device. Syntax DellCacheDeviceLocation (See Cache Device Location) Access Read-only Table 732.
Table 735. Cache Device Maximum Size Name cacheDeviceMaximumSize Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.12 Description Defines the maximum size of the cache device in kilobytes (KB). A zero (0) indicates that the size is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 736. Cache Device Current Size Name cacheDeviceCurrentSize Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.13 Description Defines the current size of the cache device in KB.
Table 740. Cache Device Error Checking and Correction (ECC) Type Name cacheDeviceECCType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.17 Description Defines the type of error correction in use by the cache device. Syntax DellCacheDeviceECCType (See Cache Device ECC Type) Access Read-only Table 741. Cache Device Associativity Name cacheDeviceAssociativity Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.18 Description Defines the type of associativity in use by the cache device.
Table 745. Memory Device Table Entry Name memoryDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1 Description Defines the Memory Device Table entry. Syntax MemoryDeviceTableEntry Access Not accessible Index memoryDevicechassisIndex , memoryDeviceIndex Table 746. Memory Device Chassis Index Name memoryDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 747.
Table 750. Memory Device Status Name memoryDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.5 Description Defines the status of the memory device. Syntax DellStatus Access Read-only Table 751. Memory Device Memory Port Index Reference Name memoryDeviceMemoryPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.6 Description Defines the index of the memory port of which this memory device is part. Syntax DellObjectRange Access Read-only Table 752.
Table 755. Memory Device Bank Location Name Name memoryDeviceBankLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.10 Description Defines the bank location name of the memory device. Syntax DellString Access Read-only Table 756. Memory Device Type Details Name memoryDeviceTypeDetails Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.11 Description Defines the detailed type of the memory device.
Table 760. Memory Device Speed Name memoryDeviceSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.15 Description Defines the attribute defines the maximum capable speed in megahertz (MHz) of the memory device. Zero indicates an unknown speed. Syntax DellUnsigned32BitRange Access Read-only Table 761. Memory Device Total Bus Width Name memoryDeviceTotalBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.16 Description Defines the total number of bits, including ECC, used by the memory device.
Syntax DellSigned32BitRange Access Read-only Table 765. Memory Device Failure Modes Name memoryDeviceFailureModes Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.20 Description Defines the failure modes of the memory device when the memoryDeviceStatus attribute is not OK. It is a bit field that can be used to report more than one type of failure mode by using a combination of the defined bit masks. Syntax DellMemoryDeviceFailureModes Access Read-only Table 766.
Access Read-only Table 770. Memory Device Speed Name Name memoryDeviceSpeedName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.25 Description This attribute defines the speed of the memory device in string format with units specified in string. Syntax DellString Access Read-only Table 771. Memory Device Rank Name memoryDeviceRank Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.26 Description 1100.0050.0001.0026 — This attribute defines the Rank of the memory device (DIMM).
Table 773. Memory Device FQDD Name memoryDeviceFQDD Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.26 Description Fully qualified device descriptor (FQDD) of the memory device. Syntax FQDDString Access Read-only Table 774. Memory Device Current Operating Speed Name memoryDeviceCurrentOperatingSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.27 Description This attribute defines the current operating speed in megahertz (MHz) of the memory device. Zero indicates an unknown speed.
Table 777. Memory Device Mapped Address Chassis Index Name memoryDeviceMappedAddresschassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 778. Memory Device Mapped Address Index Name memoryDeviceMappedAddressIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.2 Description Defines the index (one-based) of the memory device mapped address in this chassis.
Table 782. Memory Device Index Reference Name memoryDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.6 Description Defines the index of the memory device(s) associated with this memory device mapped address. Syntax DellObjectRange Access Read-only Table 783. Memory Device Mapped Address Row Position Name memoryDeviceMappedAddressRowPosition Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.
Table 787. Memory Device Mapped Address Ending Address Name memoryDeviceMappedAddressEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.11 Description Defines the physical ending address in KB of the memory device mapped address. Syntax DellUnsigned64BitRange Access Read-only Generic Device Table Table 788. Generic Device Table Name genericDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.70 Description Defines the Generic Device Table.
Syntax DellObjectRange Access Read-only Table 792. Generic Device State Capabilities Name genericDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.3 Description Defines the capabilities of the generic device. Syntax DellStateCapabilities Access Read-only Table 793. Generic Device State Settings Name genericDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.4 Description Defines the state of the generic device.
Table 797. Generic Device Name Name genericDeviceName Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.8 Description Defines the name of the generic device. Syntax DellString Access Read-only PCI Device Table Table 798. PCI Device Table Name pCIDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.80 Description Defines the PCI Device Detail Table. Syntax SEQUENCE OF PCIDeviceTableEntry Access Not accessible Table 799. PCI Device Table Entry Name pCIDeviceTableEntry Object ID 1.3.6.1.4.1.674.
Syntax DellObjectRange Access Read-only Table 802. PCI Device State Capabilities Name pCIDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.3 Description Defines the capabilities of the PCI device. Syntax DellStateCapabilities Access Read-only Table 803. PCI Device State Settings Name pCIDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.4 Description Defines the state of the PCI device. Syntax DellStateSettings Access Read-only Table 804.
Table 807. PCI Device Manufacturer Name Name pCIDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.8 Description Defines the name of the PCI device manufacturer. Syntax DellString Access Read-only Table 808. PCI Device Description Name Name pCIDeviceDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.9 Description Defines the descriptive name of the PCI device. Syntax DellString Access Read-only Table 809. PCI Device Speed Name pCIDeviceSpeed Object ID 1.3.6.1.
Table 812. PCI Device Configuration Space Table Entry Name pCIDeviceConfigurationSpaceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1 Description Defines the PCI Device Configuration Table entry. Syntax PCIDeviceConfigurationSpaceTableEntry Access Not accessible Index pCIDeviceConfigurationSpacechassisIndex , pCIDeviceConfigurationSpaceIndex Table 813. PCI Device Configuration Space Chassis Index Name pCIDeviceConfigurationSpacechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.
Table 817. PCI Device Configuration Space Status Name pCIDeviceConfigurationSpaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.5 Description Defines the status of the PCI device configuration. Syntax DellStatus Access Read-only Table 818. PCI Device Index Reference Name pCIDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.6 Description Defines the index number of PCI device that this configuration applies to. Syntax DellObjectRange Access Read-only Table 819.
Table 822. PCI Device Configuration Space Header Name pCIDeviceConfigurationSpaceHeader Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.10 Description Defines the common configuration space header of the PCI device. Syntax Octet String (SIZE(0.1025)) Access Read-only Network Device Table Table 823. Network Device Table Name networkDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.90 Description Defines the Network Device Table.
Syntax DellObjectRange Access Read-only Table 827. Network Device Status Name networkDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.3 Description Defines the status of the network device. Syntax DellStatus Access Read-only Table 828. Network Device Connection Status Name networkDeviceConnectionStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.4 Description Defines the connection status of the network device.
Table 832. Network Device Service Name Name networkDeviceServiceName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.8 Description Defines the service name of the network device. Syntax DellString Access Read-only Table 833. Network Device Driver Image Path Name Name networkDeviceDriverImagePathName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.9 Description Defines the path to the binary image of the driver for the network device. Syntax DellString Access Read-only Table 834.
Table 837. Network Device Default Gateway IP Address Name networkDeviceDefaultGatewayIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.13 Description Defines the IP address of the default gateway for the network device. Syntax IpAddress Access Read-only Table 838. Network Device DHCP Server IP Address Name networkDeviceDHCPServerIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
Table 842. Network Device PCI Device Number Name networkDevicePCIDeviceNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.18 Description Defines the PCI device number of the network device. Syntax DellUnsigned8BitRange Access Read-only Table 843. Network Device PCI Function Number Name networkDevicePCIFunctionNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.19 Description Defines the PCI function number of the network device. Syntax DellUnsigned8BitRange Access Read-only Table 844.
Table 847. Network Device TOE Capability Flags Name networkDeviceTOECapabilityFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.23 Description Defines the TCP/IP Offload Engine (TOE) capability flags of the network device. Syntax DellNetworkDeviceTOECapabilityFlags (See Network Device TOE Capability Flags) Access Read-only Table 848. Network Device TOE Enabled Name networkDeviceTOEEnabled Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
Table 852. Network Device iSCSI Enabled Name networkDeviceiSCSIEnabled Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.28 Description Defines if iSCSI is enabled for the network device. Syntax DellBoolean Access Read-only Table 853. Network Device Capabilities Name networkDeviceCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.29 Description Defines the capabilities of the network device.
Description Defines the managed system services device table entry. Syntax ManagedSystemServicesDeviceTableEntry Access Not accessible Index managedSystemServicesDeviceChassisIndex , managedSystemServicesDeviceIndex Table 857. Managed System Services Device Chassis Index Name managedSystemServicesDeviceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.1 Description Defines the index (one-based) of the chassis that contains the managed system services device.
Table 861. Managed System Services Device Storage Present Name managedSystemServicesDeviceStoragePresent Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.5 Description Defines whether storage is present on the managed system services device. Syntax DellBoolean Access Read-only Table 862. Managed System Services Device Storage Size Name managedSystemServicesDeviceStorageSize Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.
Syntax DellObjectRange Access Read-only Table 866. SD Card Unit Index Name sdCardUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.2 Description Defines the index (one-based) of the SD Card unit. Syntax DellObjectRange Access Read-only Table 867. SD Card Unit State Capabilities Name sdCardUnitStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.3 Description Defines the state capabilities of the SD Card unit. Syntax DellStateCapabilities Access Read-only Table 868.
Table 871. SD Card Unit Name Name sdCardUnitName Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.7 Description Defines the name of the SD Card unit. Syntax DellString Access Read-only Table 872. SD Card Unit Status Name sdCardUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.8 Description Defines the status of the SD Card unit. Syntax DellStatus Access Read-only SD Card Device Table Table 873. SD Card Device Table Name sdCardDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.
Syntax DellObjectRange Access Read-only Table 876. SD Card Device Index Name sdCardDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.2 Description Defines the index (one-based) of the SD Card device. Syntax DellObjectRange Access Read-only Table 877. SD Card Device Status Name sdCardDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.3 Description Defines the status of the SD Card device. Syntax DellStatus Access Read-only Table 878.
Table 881. SD Card Device Location Name Name sdCardDeviceLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.7 Description Defines the location of the SD Card device. Syntax DellString Access Read-only Table 882. SD Card Device Card Present Name sdCardDeviceCardPresent Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.8 Description Defines whether the SD Card is present for the SD Card device. Syntax DellBoolean Access Read-only Table 883.
Table 886. SD Card Device Card Available Storage Size Name sdCardDeviceCardAvailableStorageSize Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.12 Description Defines the available storage size in MB (megabytes) of the SD card for the SD card device. Syntax DellSigned32BitRange Access Read-only Table 887. SD Card Device Card Licensed Name sdCardDeviceCardLicensed Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.13 Description Defines whether the SD card is licensed by the system vendor.
unknown(2) Device type is unknown. enabled(3) Device is enabled. userDisabled(4) Device is disabled by the user. biosDisabled(5) Device has its BIOS disabled. idle(6) Device is idle. Table 890. Processor Device Status Reading Variable Name:DellProcessorDeviceStatusReading Data Type:Integer NOTE: These values are bit masks, so combination values are possible.
Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1) The upgrade device type is not one of the following: processorUpgradeIsUn known(2) Upgrade device type is unknown. processorUpgradeIsBy DaughterBoard(3) Upgrade device is on a daughter board. processorUpgradeIsBy ZIFSocket(4) Upgrade device is in a zero insertion force (ZIF) socket. processorUpgradeIsBy Replacement(5) Upgrade device is a replacement. processorUpgradeIsNo ne(6) There is no upgrade device.
processorUpgradeIsBy SocketF(24) Upgrade is by Socket F (1207). processorUpgradeIsBy SocketLGA1366(25) Upgrade is by Socket LGA1366. Table 893. Processor Device Family Variable Name:DellProcessorDeviceFamily Data Type:Integer Possible Data Values Meaning of Data Value deviceFamilyIsOther(1) The processor family is not one of the following values. deviceFamilyUnknown(2) The processor family is unknown. deviceFamilyIs8086(3) The processor family is 8086.
deviceFamilyIsIntelItaniu m2(24) The processor family is Intel Itanium 2. deviceFamilyIsK5(25) The processor family is K5. deviceFamilyIsK6(26) The processor family is K6. deviceFamilyIsK6-2(27) The processor family is K6-2. deviceFamilyIsK6-3(28) The processor family is K6-3. deviceFamilyIsAMDAthlon(2 9) The processor family is AMD Athlon. deviceFamilyIsAMD2900(30) The processor family is AMD2900. deviceFamilyIsK6-2Plus(31 ) The processor family is K6-2+.
deviceFamilyIsAlpha21264( 54) The processor family is Alpha 21264. deviceFamilyIsAlpha21364( 55) The processor family is Alpha 21364. deviceFamilyIsAMDTurionII Ultra DualMobileM(56) The processor family is AMD Turion II Ultra Dual-Core Mobile M Processor Family. deviceFamilyIsAMDTurionII DualM obileM(57) The processor family is AMD Turion II Dual-Core Mobile M Processor Family. . deviceFamilyIsAMDAthlonII DualM obileM(58) The processor family is AMD Athlon II Dual-Core Mobile M Processor Family.
deviceFamilyIs68xxx(97) The processor family is 68xxx. deviceFamilyIs68000(98) The processor family is 6800. deviceFamilyIs68010(99) The processor family is 68010. deviceFamilyIs68020(100) The processor family is 68020. deviceFamilyIs68030(101) The processor family is 68030. deviceFamilyIsAMDZen(107) The processor family is AMD Zen. deviceFamilyIsHobbit(112) The processor family is Hobbit. deviceFamilyIsCrusoe5000( 120) The processor family is Crusoe 5000.
deviceFamilyIsPARISC8000(146) The processor family is PA-RISC 8000. deviceFamilyIsPARISC7300L C( 147) The processor family is PA-RISC 7300LC. deviceFamilyIsPARISC7200(148) The processor family is PA-RISC 7200. deviceFamilyIsPARISC7100L C( 149) The processor family is PA-RISC 7100LC. deviceFamilyIsPARISC7100(150) The processor family is PA-RISC 7100. deviceFamilyIsV30(160) The processor family is V30.
deviceFamilyIsAMDAthlonX P(182) The processor family is AMD Athlon XP. deviceFamilyIsAMDAthlonM P(183) The processor family is AMD Athlon MP. deviceFamilyIsAMDDuron(18 4) The processor family is AMD Duron. deviceFamilyIsIntelPentiu mM(185) The processor family is Intel Pentium M. deviceFamilyIsIntelCelero nD(186) The processor family is Intel Celeron D. deviceFamilyIsIntelPentiu mD(187) The processor family is Intel Pentium D.
deviceFamilyIsVIAC7M(210) The processor family is VIA C7-M. deviceFamilyIsVIAC7D(211) The processor family is family is VIA C7-D. deviceFamilyIsVIAC7(212) The processor family is VIA C7. deviceFamilyIsVIAEden(213 ) The processor family is VIA Eden. deviceFamilyIsMultiCoreIn telXe on(214) The processor family is Multi-Core Intel Xeon processor. deviceFamilyIsDualCoreInt elXeo n3xxx(215) The processor family is Dual-Core Intel Xeon processor 3xxx Series.
deviceFamilyIsi860(250) The processor family is i860. deviceFamilyIsi960(251) The processor family is i960. deviceFamilyIsAMDOpteron6 200 (261) The processor family family is AMD Opteron 6200 Series Processor. Table 894. Cache Device Type Variable Name:DellCacheDeviceType Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1) System cache type is not one of the following: deviceTypeIsUnknown( 2) System cache type is unknown.
deviceWritePolicyIsW riteBack(3) Device write policy is write back. deviceWritePolicyIsW riteThrough(4) Device write policy is write through. deviceWritePolicyIsV ariesByAddress(5) Device write policy varies by address. deviceWritePolicyIsD eterminedByIO(6) Device write policy is determined by I/O query. Table 897.
deviceAssociativityI sOther(1) Device associativity is not one of the following: deviceAssociativityI sUnknown(2) Device associativity is unknown. deviceAssociativityI sDirectMapped(3) Device is direct mapped. deviceAssociativityI sTwoWaySetAssociativ e(4) Device is two-way set associative. deviceAssociativityI sFourWaySetAssociati ve(5) Device is four-way set associative. deviceAssociativityI sFullyAssociative (6) Device is fully associative.
deviceLocationIsExte rnal(4) Device location is external. Table 901. Cache Device Static Random-Access Memory (SRAM) Type Variable Name:DellCacheDeviceSRAMType Data Type:Integer Possible Data Values Meaning of Data Value deviceSRAMTypeIsOthe r(1) Device SRAM type is not one of the following: deviceSRAMTypeIsUnkn own(2) Device SRAM type is unknown. deviceSRAMTypeIsNonB urst(3) Device SRAM type is nonburst. deviceSRAMTypeIsBurs t(4) Device SRAM type is burst.
deviceFormFactorIsTS OP(10) Device form factor is TSOP. deviceFormFactorIsAR owOfChips(11) Device form factor is a row of chips. deviceFormFactorIsRI MM(12) Device form factor is RIMM. deviceFormFactorIsSO DIMM(13) Device form factor is SODIMM. deviceFormFactorIsSR IMM(14) Device form factor is SRIMM. deviceFormFactorIsFB DIMM(15) Device form factor is FB-DIMM. Table 903.
deviceTypeIsDDR2(19) Device type is DDR2. deviceTypeIsDDR2FBDI MM(20) Device type is DDR2 FB-DIMM. deviceTypeIsDDR3(24) Device type is DDR3. deviceTypeIsFBD2(25) Device type is FBD2. deviceTypeIsDDR4(26) Device type is DDR4. Table 904.
deviceTypeIsOther(1) Device type is not one of the following: deviceTypeIsUnknown( 2) Device type is unknown. deviceTypeIsAVideoDe vice(3) Device type is a video. deviceTypeIsASCSICon troller(4) Device type is a SCSI controller. deviceTypeIsAnEthern etDevice(5) Device type is Ethernet. deviceTypeIsTokenRin gDevice(6) Device type is token ring. deviceTypeIsASoundDe vice(7) Device type is sound. Table 906.
nvdimmPersistencyRestore d(16384) NVDIMM Persistency Restored nvmLifetimeLessThanFivePe rcent(32768) NVM Lifetime less than Five Percent Table 907. Network Device Connection Status Variable Name:DellNetworkDeviceConnectionStatus Data Type:Integer Possible Data Values Meaning of Data Value unknown(0) Unable to determine connection status. connected(1) Media reports that device is connected. disconnected(2) Media reports that device is disconnected.
none(0) Querying for TOE capability is not supported. unknown(1) Querying for TOE capability is supported but query returned an error. available(2) Device has TOE capability. notAvailable(4) Device does not have TOE capability. cannotBeDetermined(8 ) Querying for TOE capability is supported but an error prevented querying. driverNotResponding( 16) Querying for TOE capability is supported but driver did not respond to query. Table 910.
Table 912. Network Device Capabilities Variable Name:DellNetworkDeviceCapabilities Data Type:Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value notSupported(0) Device does not support reporting capabilities through this attribute. supported(1) Device supports reporting capabilities through this attribute. toe(2) Device has TOE capability. iscsiOffload(4) Device has iSCSI Offload capability.
vFlash(4) Device type is Virtual Flash (vFlash.) Table 916. SD Card Device Config Capabilities Variable Name:DellSDCardDeviceConfigCapabilities Data Type:Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) SD card device has none of the following capabilities. sdCapable(1) SD media can be enabled. vFlashCapable(2) Virtual Flash (vFlash) can be enabled. Table 917.
Table 919. SD Card Device Card Licensed Variable Name:DellSDCardDeviceCardLicensed Data Type:Integer Possible Data Values Meaning of Data Value unlicensed(0) SD card is not licensed by system vendor. licensed(1) SD card is licensed by system vendor. ipmiReady(2) Device is IPMI ready. fullReady(4) Device is full ready. offline(8) Device is offline. failed(16) Device is failed. active(32) Device is active. bootable(64) Device is bootable. writeProtect(128) Device is write-protected.
Index systemSlotchassisIndex , systemSlotIndex Table 922. System Slot Chassis Index Name systemSlotchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 923. System Slot Index Name systemSlotIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.2 Description Defines the index (one-based) of the system slot in this chassis. Syntax DellObjectRange Access Read-only Table 924.
Syntax DellStatus Access Read-only Table 927. System Slot Current Usage Name systemSlotCurrentUsage Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.6 Description Defines the current usage of the system slot. Syntax DellStatus Access Read-only Table 928. System Slot Type Name systemSlotType Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.7 Description Defines the type of the system slot. Syntax DellSystemSlotType (System Slot Type) Access Read-only Table 929.
Syntax DellUnsigned32BitRange Access Read-only Table 932. System Slot Category Name systemSlotCategory Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.11 Description Defines the system slot category. Syntax DellUnsigned32BitRange Access Read-only Table 933. System Slot Hot-Plug Bus Width Name systemSlotHotPlugBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.12 Description Defines the bus width of the hot-plug system slot.
Table 936. System Slot State Capabilities Variable Name: DellSystemSlotStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value systemSlotHotPlugIsUnknown (1) The system slot’s capabilities are unknown. systemSlotHotPlugIsHotPlug gableCapable(2) The system slot supports hot-plug. systemSlotHotPlugCanBePower edOn(4) The system slot power (and corresponding light-emitting diode [LED]) can be powered on.
systemSlotHotPlugIsAtAttention(8) The system slot attention state (and corresponding LED) can be set. systemSlotHotPlugIsHotPluggable(2) The system slot supports hot-plug. systemSlotHotPlugIsPoweredOn(4) The system slot power (and corresponding LED) is on. systemSlotHotPlugIsAtAttention(8) The system slot attention state (and corresponding LED) is on. systemSlotHotPlugHasPowerFaulted (16) Power on fault (and corresponding LED) was detected due to a short or overcurrent.
systemSlotIsPCI(6) The system slot is Peripheral Component Interconnect (PCI). systemSlotIsPCMCIA(7) . The system slot is compliant with the Personal Computer Memory Card International Association (PCMCIA) standards systemSlotIsVLVESA(8) The system slot is Very Low Voltage Enterprise System Architecture (VLVESA). systemSlotIsProprietary(9) The system slot is proprietary. systemSlotIsProcessorCard(10) The system slot is a processor card.
Possible Data Values Meaning of Data Value systemSlotUsageIsOther(1) The system slot usage is not one of following: systemSlotUsageIsUnknown(2) The system slot usage is unknown. systemSlotUsageIsAvailable(3) The system slot is available. systemSlotUsageIsInUse(4) The system slot is in use. Table 940.
busWidthIs1xOrx1(8) The system slot bus width is 1x or x1. busWidthIs2xOrx2(9) The system slot bus width is 2x or x2. busWidthIs4xOrx4(10) The system slot bus width is 4x or x4. busWidthIs8xOrx8(11) The system slot bus width is 8x or x8. busWidthIs12xOrx12(12) The system slot bus width is 12x or x12. busWidthIs16xOrx16(13) The system slot bus width is 16x or x16. busWidthIs32xOrx32(14) The system slot bus width is 32x or x32.
Table 943. Physical Memory Array Table Name physicalMemoryArrayTable Object ID 1.3.6.1.4.1.674.10892.1.1300.10 Description Defines the Physical Memory Array Table. Syntax PhysicalMemoryArrayTableEntry Access Not accessible Table 944. Physical Memory Array Table Entry Name physicalMemoryArrayTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1 Description Defines the Physical Memory Array Table entry.
Access Read-only Table 948. Physical Memory Array State Settings Name physicalMemoryArrayStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.4 Description Defines the state of the physical memory array. Syntax DellStateSettings Access Read-only Table 949. Physical Memory Array Status Name physicalMemoryArrayStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.5 Description Defines the status of the physical memory array. Syntax DellStatus Access Read-only Table 950.
Table 953. Physical Memory Array Maximum Size NOTE: physicalMemoryArrayMaximumSize is no longer in use. This attribute is deprecated and replaced by physicalMemoryArrayExtendedMaximumSize. Name physicalMemoryArrayMaximumSize Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.9 Description Defines the size in KB of the physical memory array. Syntax DellUnsigned32BitRange Access Read-only Table 954. Physical Memory Array Total Number Sockets Name physicalMemoryArrayTotalNumberSockets Object ID 1.3.6.1.
Access Read-only Table 958. Physical Memory Array ECC Error Noncritical Threshold Name physicalMemoryArrayECCErrorNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.14 Description Defines the value of the physical memory array ECC error noncritical threshold. Syntax DellSigned32BitRange Access Read-only Table 959. Physical Memory Array Redundant Memory Unit Index Reference Name physicalMemoryArrayRedundantMemoryUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.
Table 962. Physical Memory Array Mapped Table Entry Name PhysicalMemoryArrayMappedTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1 Description Defines the Physical Memory Array Mapped Table entry. Syntax PhysicalMemoryArrayMappedTableEntry Access Not accessible Index physicalMemoryArrayMappedchassisIndex , physicalMemoryArrayMappedIndex Table 963. Physical Memory Array Mapped Chassis Index Name physicalMemoryArrayMappedchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.
Access Read-only Table 967. Physical Memory Array Mapped Status Name physicalMemoryArrayMappedStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.5 Description Defines the status of the memory array mapped address. Syntax DellStatus Access Read-only Table 968. Physical Memory Array Index Reference Name physicalMemoryArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.6 Description Defines the index to the associated physical memory array in this chassis.
Access Read-only Physical Memory Configuration Table This table defines how the physical memory of a system chassis is set up, for example, which redundant memory types are supported and whether redundant memory is active. The following object sets up the Physical Memory Configuration Table: Table 972. Physical Memory Configuration Table Name physicalMemoryConfigTable Object ID 1.3.6.1.4.1.674.10892.1.1300.30 Description Defines the Physical Memory Configuration Table.
Access Read-only Table 976. Physical Memory Configuration State Capabilities Name physicalMemoryConfigStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.3 Description Defines the state capabilities of the physical memory configuration. Syntax DellPhysicalMemoryConfigStateCapabilities Access Read-only Table 977. Physical Memory Configuration State Settings Name physicalMemoryConfigStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.
Table 981. Physical Memory Configuration MOM Capabilities Name physicalMemoryConfigMOMCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.8 Description Defines the Memory Operating Mode capabilities of the physical memory. Syntax DellPhysicalMemoryConfigMOMCapabilities Access Read-only Table 982. Physical Memory Configuration MOM Settings Name physicalMemoryConfigMOMSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.
Table 985. Physical Memory Logging Chassis Index Name physicalMemoryLoggingChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.1 Description Defines the index (one-based) of the chassis associated with the physical memory logging. Syntax DellObjectRange Access Read-only Table 986. Physical Memory Logging Index Name physicalMemoryLoggingIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.2 Description Defines the index (one-based) of the physical memory logging.
The following object sets up the Redundant Memory Unit Table: Table 990. Redundant Memory Unit Table Name redundantMemoryUnitTable Object ID 1.3.6.1.4.1.674.10892.1.1300.50 Description Defines the Redundant Memory Unit Table. Syntax SEQUENCE OF RedundantMemoryUnitTableEntry Access Not accessible Table 991. Redundant Memory Unit Table Entry Name redundantMemoryUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1 Description Defines the Redundant Memory Unit Table entry.
Syntax DellStateCapabilities Access Read-only Table 995. Redundant Memory Unit State Settings Name redundantMemoryUnitStatesettings Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.4 Description Defines the state settings of the redundant memory unit. Syntax DellStateSettings Access Read-only Table 996. Redundant Memory Unit Redundancy Status Name redundantMemoryUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.
Table 999. Physical Memory Card Table Name physicalMemoryCardTable Object ID 1.3.6.1.4.1.674.10892.1.1300.60 Description Defines the Physical Memory Card Table. Syntax SEQUENCE OF PhysicalMemoryCardTableEntry Access Not accessible Table 1000. Physical Memory Card Table Entry Name physicalMemoryCardTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1 Description Defines the Physical Memory Card Table Entry.
Access Read-only Table 1004. Physical Memory Card State Settings Name physicalMemoryCardStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.4 Description Defines the state settings of the Physical Memory Card. Syntax DellStateSettings Access Read-only Table 1005. Physical Memory Card Status Name physicalMemoryCardStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.5 Description Defines the status of the Physical Memory Card. Syntax DellStatus Access Read-only Table 1006.
Access Read-only Table 1009. Physical Memory Card Physical Memory Array Index Reference Name physicalMemoryCardPhyMemArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.9 Description Defines the index (one-based) of the Physical Memory Array Table entry for the physical memory array with the same chassis index that this physical memory card is associated with.
Possible Data Values Meaning of Data Value memoryArrayECCTypeIsOther(1) There is not one of the following: memoryArrayECCTypeIsUnknown(2) The memory array ECC type is unknown. memoryArrayECCTypeIsNone(3) The memory array ECC type is none. memoryArrayECCTypeIsParity(4) The memory array ECC type is parity. memoryArrayECCTypeIsSingleBitECC(5) The memory array ECC type is Correctable Memory Event ECC. memoryArrayECCTypeIsMultiBitECC(6) The memory array ECC type is Uncorrectable Memory Event ECC.
spareCapable(2) mirrorCapable(4) Mirror redundant memory feature is supported. spareAndMirrorCapable(6) Spare and mirror redundant memory features are supported. raidCapable(8) Redundant Array of Independent disks (RAID) redundant memory feature is supported. dddcCapable(16) DDDC redundancy is supported. Table 1015.
BIOS Setup Control Group Basic Input/Output System (BIOS) Setup Control Group variables provide information about the functions that the BIOS performs in your system. This management information base (MIB) group includes variables for the boot sequence, speakers, diskettes, ports, network interface controllers (NICs), and the Wakeup on local area network (LAN) feature.
Table 1020. BIOS Setup Control Chassis Index Name biosSetUpControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1021. BIOS Setup Control (BSUC) Pointing Device Control Capabilities Name bSUCpointingDeviceControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.2 Description Defines the capabilities of the pointing device.
Table 1025. BIOS Setup Control Numeric Lock Control Capabilities Name bSUCnumLockControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.6 Description Defines the capabilities of the numeric lock. Syntax DellStateCapabilities Access Read-only Table 1026. BIOS Setup Control Numeric Lock Control Settings Name bSUCnumLockControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.7 Description Defines the state of the numeric lock.
Table 1030. BIOS Setup Control Processor Serial Number Control Settings Name bSUCprocessorSerialNumberControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.11 Description Defines the state of the processor serial number. Syntax DellStateSettings Access Read-only Table 1031. BIOS Setup Control Processor Serial Number Control Status Name bSUCprocessorSerialNumberControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.12 Description Defines the status of the processor serial number.
Table 1035. BIOS Setup Control Speaker Control Status Name bSUCspeakerControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.16 Description Defines the status of speaker control. Syntax DellStatus Access Read-only Table 1036. BIOS Setup Control Speaker Control Name Name bSUCspeakerControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.17 Description Defines the setup BIOS name of the speaker control. Syntax DellString Access Read-only Table 1037.
Table 1040. BIOS Setup Control NIF Wakeup on LAN Control Name Name bSUCnIFwakeonLanControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.21 Description Defines the setup BIOS name of the NIF Wakeup on LAN. Syntax DellString Access Read-only Table 1041. BIOS Setup Control Boot Sequence Control Capabilities Unique Name bSUCbootSequenceControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.22 Description Defines the capabilities of the boot sequence.
Table 1045. BIOS Setup Control Administrator Password Control Capabilities Unique Name bSUCadministratorPasswordControlCapabilities Unique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.26 Description Defines the capabilities of the administrator password control. Syntax DellBIOSPasswordControlCapabilitiesUnique Access Read-only Table 1046. BIOS Setup Control Administrator Password Control Settings Unique Name bSUCadministratorPasswordControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.
Table 1050. BIOS Setup Control User Password Control Capabilities Unique Name bSUCuserPasswordControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.31 Description Defines the capabilities of user password control. Syntax DellBIOSPasswordControlCapabilitiesUnique Access Read-only Table 1051. BIOS Setup Control User Password Control Settings Unique Name bSUCuserPasswordControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
Table 1055. BIOS Setup Control TPM Security Control Capabilities Name bSUCtpmSecurityControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.36 Description Defines the BIOS setup control capabilities of Trusted Platform Module (TPM) security. Syntax DellTPMSecurityControlCapabilities Access Read-only Table 1056. BIOS Setup Control TPM Security Control Setting Name bSUCtpmSecurityControlSetting Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
Access Not accessible Table 1060. SCSI Control Table Entry Name sCSIControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1 Description x Defines the SCSI Control Table entry. Syntax SCSIControlTableEntry Access Not accessible Index sCSIControlchassisIndex , sCSIControlIndex Table 1061. SCSI Control Chassis Index Name sCSIControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.1 Description Defines the index (one-based) of this chassis.
Access Read-only Table 1065. SCSI Control Status Name sCSIControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.5 Description Defines the status of the SCSI controller. Syntax DellStatus Access Read-only Table 1066. SCSI Control Name Name sCSIControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.6 Description Defines the setup BIOS name of the SCSI controller. Syntax DellString Access Read-only Parallel Port Control Table Table 1067.
Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1070. Parallel Port Control Index Name parallelPortControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.2 Description Defines the index (one-based) of the parallel port in this chassis. Syntax DellObjectRange Access Read-only Table 1071. Parallel Port Control Capabilities Unique Name parallelPortControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.
Access Read-only Table 1075. Parallel Port Control Mode Capabilities Unique Name parallelPortControlModeCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.7 Description Defines the mode capabilities of the parallel port. Syntax DellParallelPortControlModeCapabilitiesUnique Access Read-only Table 1076. Parallel Port Control Mode Settings Unique Name parallelPortControlModeSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.
Description Defines index (one-based) of this chassis. Syntax DellObjectRange Access read-only Table 1080. Serial Port Control Index Name serialPortControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.2 Description Defines the index (one-based) of the serial port in this chassis. Syntax DellObjectRange Access read-only Table 1081. Serial Port Control Capabilities Unique Name serialPortControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.
USB Control Table These objects enable you to track the attributes of your Universal Serial Bus (USB). Table 1085. USB Control Table Name usbControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.50 Description Defines the USB Table. Syntax UsbControlTableEntry Access Not accessible Table 1086. USB Control Table Entry Name usbControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1 Description Defines the USB Table entry.
Description Defines the capabilities of the USB. Syntax DellStateCapabilities Access Read-only Table 1090. USB Control Settings Name usbControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.4 Description Defines the control settings for the USB. Syntax DellStateSettings Access Read-only Table 1091. USB Control Status Name usbControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.5 Description Defines the status of the USB. Syntax DellStatus Access Read-only Table 1092.
Description Defines the IDE Control Table entry. Syntax IdeControlTableEntry Access Not accessible Index ideControlchassisIndex , ideControlIndex Table 1095. IDE Control Chassis Index Name ideControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1096. IDE Control Index Name ideControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.
Description Defines the status for the IDE controller. Syntax DellStatus Access Read-only Table 1100. IDE Control Name Name ideControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.6 Description Defines the setup BIOS name for the IDE controller. Syntax DellStatus Access Read-only Diskette Control Table Table 1101. Diskette Control Table Name disketteControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.70 Description Defines the Diskette Control Table.
Table 1104. Diskette Control Index Name disketteControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.2 Description Defines the index of the diskette controllers in this chassis. Syntax DellObjectRange Access Read-only Table 1105. Diskette Control Capabilities Unique Name disketteControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.3 Description Defines the capabilities of the diskette controller.
Table 1109. Network Interface Control Table Name networkInterfaceControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.80 Description Defines the Network Interface Control Table. Syntax NetworkInterfaceControlTableEntry Access Not accessible Table 1110. Network Interface Control Table Entry Name networkInterfaceControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1 Description Defines the Network Interface Control Table entry.
Table 1114. Network Interface Control Settings Unique Name networkInterfaceControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.4 Description Defines the control settings for the NIC. Syntax DellNetworkInterfaceControlSettingsUnique (See Network Interface Control Settings) Access Read-only Table 1115. Network Interface Control Status Name networkInterfaceControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.5 Description Defines the status of the NIC.
Access Not accessible Index biosSettingChassisIndex , biosSettingIndex Table 1119. BIOS Setting Chassis Index Name biosSettingChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.1 Description Defines the index (one based) of the associated chassis. Syntax DellObjectRange Access Read-only Table 1120. BIOS Setting Index Name biosSettingIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.2 Description Defines the index (one based) of the BIOS setting.
Access Read-only Table 1124. BIOS Setting Current Value Name biosSettingCurrentValue Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.6 Description Defines the current value of the BIOS setting. Syntax DisplayString Access Read-only Table 1125. BIOS Setting Pending Value Name biosSettingPendingValue Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.7 Description Defines the pending value of the BIOS setting. Syntax DisplayString Access Read-only Table 1126.
Table 1129. BIOS Setting Group Display Name Name biosSettingGroupDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.11 Description Defines the display name of the BIOS setting group for the BIOS setting. Syntax DisplayString Access Read-only Table 1130. BIOS Setting FQDD Name biosSettingFQDD Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.12 Description Fully Qualified Device Descriptor (FQDD) for the BIOS setting.
high(16) Speaker control volume is high. Table 1133. Network Interface (NIF) Wakeup on LAN Capabilities Unique Variable Name: DellNIFwakeonLanControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Setup BIOS Wakeup on LAN capabilities are unknown. enableCapable(2) Setup BIOS is capable of enabling the NIF Wakeup on LAN. addInCardCapable(4) Setup BIOS is capable of enabling Wakeup on LAN by option card.
Table 1136. Boot Sequence Control Settings Unique Variable Name: DellBootSequenceControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value bootSequenceUnknown(1) Boot sequence state is unknown. bootFromDisketteFirst(2) Setup BIOS is set to boot by diskette first. bootFromHardDriveFirst(4) Setup BIOS is set to boot by IDE hard drive first. bootFromDeviceList(8) Setup BIOS is set to boot by a device list. bootFromCDROMFirst(16) Setup BIOS is set to boot by CD first.
passwordControlJumperDisabled(4) Setup BIOS has determined that password control has been disabled by a jumper. Table 1140. TPM Security Control Capabilities Variable Name: DellTPMSecurityControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value offCapable(1) TPM security can be Off. onWithPrebootMeasurementsCap able(2) TPM security can be On with Pre-boot Measurements. onWithoutPrebootMeasurements Capable(4) TPM security can be On without Pre-boot Measurements. Table 1141.
Possible Data Values Meaning of Data Value unknown(1) Parallel port state is unknown. enabled(2) Setup BIOS has enabled the parallel port. lpt1(4) Setup BIOS supports parallel port 1. lpt1Enabled(6) Setup BIOS has enabled parallel port 1. lpt2(8) Setup BIOS supports parallel port 2. lpt2Enabled(10) Setup BIOS has enabled parallel port 2. lpt3(16) Setup BIOS supports parallel port 3. Table 1144.
com1OrCom3CapableAndAuto ConfigCapable(86) Setup BIOS has enabled autoconfiguration of COM1 and COM3 serial ports. com2OrCom4CapableAndAuto ConfigCapable(106) Setup BIOS has enabled autoconfiguration of COM2 and COM4 serial ports. allcomCapable(126) Setup BIOS is capable of enabling or autoconfiguring all serial ports. Table 1146.
Table 1149. Network Interface Control Capabilities Variable Name: DellNetworkInterfaceControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Unknown setup BIOS network interface capabilities. enableCapable(2) Setup BIOS is capable of enabling the network interface. enableWithoutPXECapable(4) Setup BIOS is capable of enabling the NIF without Pre-boot eXecution Environment (PXE). Table 1150.
• LRA Global Settings Table • LRA Action Table LRA Global Settings The global settings table allows the systems manager to determine what LRA capabilities exist for a specific system that is running Server Administrator. Some machines may support all or some of the capabilities described in DellLocalResponseAgentCapabilitiesUnique. The LRA Global Settings Table also defines thermal shutdown capabilities and settings.
Table 1156. LRA Global Settings Disable Time-out Value Name lRAGlobalSettingsDisableTimeoutValue Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.3 Description Defines the time-out duration countdown, in seconds, that the LRA global settings are disabled after a system shutdown and reboot. Syntax DellUnsigned32BitRange Access Read-only Table 1157. LRA Global Settings Capabilities Unique Name lRAGlobalSettingsCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.
Description Defines the LRA Action Table. Syntax SEQUENCE OF LRAActionTableTableEntry Access Not accessible Table 1161. LRA Action Table Entry Name lRAActionTableTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1 Description Defines the LRA Action Table entry. Syntax LRAActionTableTableEntry Access Not accessible Index lRAActionTablechassisIndex , lRAActionTableActionNumberIndex Table 1162. LRA Action Table Chassis Index Name lRAActionTablechassisIndex Object ID 1.3.6.1.4.1.674.
• • • • • • 1553 — log near full action definition 1554 — log full action definition 1603 — processor warning action definition 1604 — processor failure action definition 1703 — battery warning action definition 1704 — battery failure action definition Syntax DellUnsigned16BitRange Access Read-only Table 1164. LRA Action Table User Application Name Name lRAActionTableUserApplicationName Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.
rebootCapable(16) The LRA can reboot the system. powerCycleCapable(32) The LRA is capable of a system power cycle. powerOFFCapable(64) The LRA can shut the system power off. executeApplicationCapable(256) The LRA can execute a user mode application. lraFullyCapable(383) The LRA has all of the preceding capabilities. Table 1167.
Cost of Ownership Group The Cost of Ownership (COO) Group provides a full set of cost-tracking objects, including fields for the computer’s manufacturer, insurer, lessor, warranty, user, trouble tickets, and many others. You can use these management information base (MIB) objects to obtain accurate and complete measurements of the cost of each computer asset in your organization.
Table 1171. COO Chassis Index Name coochassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.1 Description Defines the index (one-based) of this chassis. Syntax CooTableEntry Access Read-only Table 1172. COO State Name cooState Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.2 Description Defines the acquisition state of the system. Syntax DellStateSettings Access Read-only Table 1173. COO Acquisition Purchase Cost Name cooAquisitionPurchaseCost Object ID 1.3.6.1.4.1.674.10892.1.1600.
Table 1176. COO Acquisition Purchase Order Name cooAquisitionPurchaseOrder Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.6 Description Defines the purchase order number of the system. Syntax DellUnsigned32BitRange Access Read-only Table 1177. COO Acquisition Purchase Date Name Name cooAquisitionPurchaseDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.7 Description Defines the purchase date and time of the system. Syntax DellDateName Access Read-only Table 1178.
Table 1181. COO Cost Center Information Vendor Name Name cooCostCenterInformationVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.11 Description Defines the cost center name of the system. Syntax DellCostofOwnershipString Access Read-only Table 1182. COO User Information User Name Name cooUserInformationUserName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.12 Description Defines the name of the user for this system. Syntax DellCostofOwnershipString Access Read-only Table 1183.
Table 1186. COO Extended Warranty Provider Name Name cooExtendedWarrantyProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.16 Description Defines the name of the extended warranty provider for this system. Syntax DellCostofOwnershipString Access Read-only Table 1187. COO Ownership Code Name cooOwnershipCode Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.17 Description Defines the ownership code for this system.
Table 1191. COO Deployment Duration Type Name cooDeploymentDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.21 Description Defines the deployment time units for this system. Syntax DellCooHourDayDurationType (See COO Hour Day Duration Type) Access Read-only Table 1192. COO Training Name Name cooTrainingName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.22 Description Defines the training that the user has for this system.
Table 1196. COO Outsourcing Provider Fee Name Name cooOutsourcingProviderFeeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.26 Description Defines any additional outsourcing charge for service. Syntax DellCostofOwnershipString Access Read-only Table 1197. COO Outsourcing Provider Service Level Name Name cooOutsourcingProviderServiceLevelName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.27 Description Defines the service level agreement for the system.
Table 1201. COO Box Central Processing Unit (CPU) Serial Number Name Name cooBoxCPUSerialNumberName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.31 Description Defines the name of the CPU serial number for the system. Syntax DellCostofOwnershipString Access Read-only Table 1202. COO Operating System Upgrade Type Name Name cooOperatingSystemUpgradeTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.32 Description Defines the name of the operating system on this system.
Table 1206. COO Depreciation Duration Type Name cooDepreciationDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.36 Description Defines the unit of time for the depreciation of this system. Syntax DellCooMonthYearDurationType Access Read-only Table 1207. COO Depreciation Percentage Name cooDepreciationPercentage Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.37 Description Defines the percentage of depreciation for this system.
Syntax SEQUENCE OF CooServiceContractTableEntry Access Not accessible Table 1211. COO Service Contract Table Entry Name cooServiceContractTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1 Description Defines the COO Service Contract Table entry. Syntax CooServiceContractTableEntry Access Not accessible Index cooServiceContractchassisIndex , cooServiceContractIndex Table 1212. COO Service Contract Chassis Index Name cooServiceContractchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.
Table 1215. COO Service Contract Was Renewed Name cooServiceContractWasRenewed Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.4 Description Specifies whether the service contract for this system was renewed. Syntax DellBoolean Access Read-only Table 1216. COO Service Contract Type Name Name cooServiceContractTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.5 Description Defines the name of the service contract type for this system.
Syntax cooCostEventLogTableEntry Access Not accessible Index cooCostEventLogchassisIndex , cooCostEventLogIndex Table 1220. COO Cost Event Log Chassis Index Name cooCostEventLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1221. COO Cost Event Log Index Name cooCostEventLogIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.
Table 1224. COO Cost Event Log Duration Type Name cooCostEventLogDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.5 Description Defines the duration type of the event for this system. Syntax DellCOOHourDayDurationType (See COO Hour Day Duration Type) Access Read-only Table 1225. COO Cost Event Log Description Name Name cooCostEventLogDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.6 Description Defines the name of the event description.
Table 1228. COO Warranty Chassis Index Name cooWarrantychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1229. COO Warranty Index Name cooWarrantyIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.2 Description Defines the index of the warranty for this system. Syntax DellObjectRange Access Read-only Table 1230. COO Warranty State Name cooWarrantyState Object ID 1.3.6.1.4.
Table 1233. COO Warranty End Date Name Name cooWarrantyEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.6 Description Defines the warranty end date for this system. Syntax DellDateName Access Read-only Table 1234. COO Warranty Cost Name cooWarrantyCost Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.7 Description Defines the cost of the warranty for this system.
Table 1237. COO Lease Information Chassis Index Name cooLeaseInformationchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1238. COO Lease Information Index Name cooLeaseInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.2 Description Defines the index of the lease information for this system. Syntax DellObjectRange Access Read-only Table 1239.
Table 1242. COO Lease Information Lease Rate Factor Name cooLeaseInformationLeaseRateFactor Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.6 Description Defines the rate factor for the lease on this system. Syntax DellUnsigned32BitRange Access Read-only Table 1243. COO Lease Information End Date Name Name cooLeaseInformationEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.7 Description Defines the end date for the lease on this system. Syntax DellDateName Access Read-only Table 1244.
Access Not accessible Table 1247. COO Schedule Number Table Entry Name cooScheduleNumberTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1 Description Defines the COO Schedule Number Information Table entry. Syntax CooScheduleNumberTableEntry Access Not accessible Index cooScheduleNumberchassisIndex , cooScheduleNumberIndex Table 1248. COO Schedule Number Chassis Index Name cooScheduleNumberchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.
Description Defines the lease information index number to reference the schedule number. Syntax DellUnsigned32BitRange Access Read-only Table 1252. COO Schedule Number Description Name Name cooScheduleNumberDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.5 Description Describes the schedule number information. Syntax DellCostofOwnershipString Access Read-only COO Options Table Table 1253. COO Options Table Name cooOptionsTable Object ID 1.3.6.1.4.1.674.10892.1.1600.
Table 1256. COO Options Index Name cooOptionsIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.2 Description Defines the index (one-based) of the option information for this system. Syntax DellObjectRange Access Read-only Table 1257. COO Options State Name cooOptionsState Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.3 Description Defines the option information state for this system. Syntax DellStateSettings Access Read-only Table 1258.
Access Not accessible Table 1261. COO Maintenance Table Entry Name cooMaintenanceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1 Description Defines the COO Maintenance Table entry. Syntax CooMaintenanceTableEntry Access Not accessible Index cooMaintenancechassisIndex , cooMaintenanceIndex Table 1262. COO Maintenance Chassis Index Name cooMaintenancechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.1 Description Defines the index (one-based) of this chassis.
Description Defines the start date for maintenance on this system. Syntax DellDateName Access Read-only Table 1266. COO Maintenance End Date Name Name cooMaintenanceEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.5 Description Defines the end date for maintenance on this system. Syntax DellDateName Access Read-only Table 1267. COO Maintenance Provider Name Name cooMaintenanceProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.
Table 1270. COO Repair Table Entry Name cooRepairTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1 Description Defines the COO Repair Table entry. Syntax CooRepairTableEntry Access Not accessible Index cooRepairchassisIndex , cooRepairIndex Table 1271. COO Repair Chassis Index Name cooRepairchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1272.
Access Read-only Table 1275. COO Repair Vendor Name Name cooRepairVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.5 Description Defines the name of the vendor that repairs this system. Syntax DellStateSettings Access Read-only COO Support Information Table Table 1276. COO Support Information Table Name cooSupportInformationTable Object ID 1.3.6.1.4.1.674.10892.1.1600.100 Description Defines the COO Support Information Table.
Table 1279. COO Support Information Index Name cooSupportInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.2 Description Defines the index (one-based) for this system’s support information. Syntax DellObjectRange Access Read-only Table 1280. COO Support Information State Name cooSupportInformationState Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.3 Description Defines the support information state for this system. Syntax DellStateSettings Access Read-only Table 1281.
Table 1284. COO Support Information Fix Type Name Name cooSupportInformationFixTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.7 Description Defines the method used to fix the problem. Syntax DellCostofOwnershipString Access Read-only COO Trouble Ticket Table The MIB objects in the Trouble Ticket Table allows you to track details of any trouble tickets that you open for your system. Table 1285. COO Trouble Ticket Table Name cooTroubleTicketTable Object ID 1.3.6.1.4.1.674.10892.1.1600.
Table 1288. COO Trouble Ticket Index Name cooTroubleTicketIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.2 Description Defines the index (one-based) of the system’s trouble ticket information. Syntax DellObjectRange Access Read-only Table 1289. COO Trouble Ticket State Name cooTroubleTicketState Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.3 Description Defines the trouble ticket information state for this system. Syntax DellStateSettings Access Read-only Table 1290.
other(1) The ownership code is not one of following: unknown(2) The ownership code is unknown. owned(3) The ownership code is owned. leased(4) The ownership code is leased. rented(5) The ownership code is rented. offOfLease(6) The ownership code is off of lease. transfer(7) The ownership code is transfer. Table 1293. COO Hour Day Duration Type Variable Name: DellCooHourDayDurationType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Duration time type is unknown.
between two or more systems in the event of a failure. Scalability is achieved by balancing the load of an application across several computer systems. Simpler management is achieved by using virtual servers, as opposed to managing each individual computer system. Cluster Group The Cluster Group defines attributes such as the number of systems in the cluster, capabilities of the cluster, type of cluster, and name of the cluster. Cluster Table The following table defines the attributes of the cluster.
Syntax DellObjectRange Access Read-only Table 1300. Cluster State Capabilities Name clusterStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.3 Description Defines the state capabilities of the cluster. Syntax DellStateCapabilities Access Read-only Table 1301. Cluster State Settings Name clusterStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.4 Description Defines the state settings of the cluster. Syntax DellStateSettings Access Read-only Table 1302.
Table 1305. Cluster Name Name clusterName Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.8 Description Defines the name of the cluster. Syntax DellString Access Read-only Cluster Group Variable Values This section includes definitions for Server Administrator-specific variable values used in this section. Table 1306. Cluster Type Variable Name:DellClusterType Data Type:Integer Possible Data Values Meaning of Data Value unknown(1) The cluster type is unknown.
Baseboard Management Controller Table Table 1307. BMC Table Name bmcTable Object ID 1.3.6.1.4.1.674.10892.1.1900.10 Description Defines the Baseboard Management Controller Table. Syntax SEQUENCE OF BmcTableEntry Access Not accessible Table 1308. BMC Table Entry Name bmcTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1 Description Defines the Baseboard Management Controller (BMC) Table Entry. Syntax BmcTableEntry Access Not accessible Index bmcChassisIndex , bmcIndex Table 1309.
Syntax DellStateCapabilities Access Read-only Table 1312. BMC State Settings Name bmcStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.4 Description Defines the state settings of the BMC. Syntax DellStateSettings Access Read-only Table 1313. BMC Status Name bmcStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.5 Description Defines the status of the BMC. Syntax DellStatus Access Read-only Table 1314. BMC Display Name Name bmcDisplayName Object ID 1.3.6.1.4.1.674.10892.1.
Table 1317. BMC GUID Name bmcGUID Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.9 Description Defines the Globally Unique ID (GUID) of the BMC. Syntax Octet String Access Read-only Table 1318. BMC Type Name bmcType Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.10 Description Defines the type of the BMC. Syntax DellManagementControllerType Access Read-only Table 1319. BMC Module Name Name bmcModuleName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.
Table 1322. BMC Blade Form Factor Name bmcBladeFormFactorName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.14 Description Defines Blade Form Factor Syntax DellBladeFormFactorType Access Read-only Baseboard Management Controller Serial Interface Table 1323. BMC Serial Interface Table Name bmcSerialInterfaceTable Object ID 1.3.6.1.4.1.674.10892.1.1900.20 Description Defines the BMC Serial Interface Table. Syntax SEQUENCE OF BmcSerialInterfaceTableEntry Access Not accessible Table 1324.
Table 1326. BMC Serial Interface BMC Index Name bmcSerialInterfaceBMCIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.2 Description Defines the index (one-based) of the associated BMC. Syntax DellObjectRange Access Read-only Table 1327. BMC Serial Interface Index Name bmcSerialInterfaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.3 Description Defines the index (one-based) of the BMC serial interface. Syntax DellObjectRange Access Read-only Table 1328.
Table 1331. BMC Serial Interface Channel Number Name bmcSerialInterfaceChannelNumber Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.7 Description Defines the BMC channel number of the BMC serial interface. Syntax DellUnsigned8BitRange Access Read-only Table 1332. BMC Serial Interface Connection Mode Capabilities Name bmcSerialInterfaceConnectionModeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.8 Description Defines the connection mode capabilities of the BMC serial interface.
Baseboard Management Controller LAN Interface Table Table 1336. BMC LAN Interface Name bmcLANInterfaceTable Object ID 1.3.6.1.4.1.674.10892.1.1900.30 Description Defines the Baseboard Management Controller (BMC) LAN Interface Table. Syntax SEQUENCE OF BmcLANInterfaceTableEntry Access Not accessible Table 1337. BMC LAN Interface Table Entry Name bmcLANInterfaceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.30.
Table 1340. BMC LAN Interface Index Name bmcLANInterfaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.3 Description Defines the index (one-based) of the BMC LAN interface. Syntax DellObjectRange Access Read-only Table 1341. BMC LAN Interface State Capabilities Name bmcLANInterfaceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.4 Description Defines the state capabilities of the BMC LAN interface. Syntax DellStateCapabilities Access Read-only Table 1342.
Table 1345. BMC LAN Interface IP Address Source Name bmcLANInterfaceIPAddressSource Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.8 Description Defines the source type of the IP address of the BMC LAN interface. Syntax DellBMCLANIPAddressSourceType Access Read-only Table 1346. BMC LAN Interface IP Address Name bmcLANInterfaceIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.9 Description Defines the IP address of the BMC LAN interface. Syntax IpAddress Access Read-only Table 1347.
Table 1350. BMC LAN Interface Alert Community Name Name bmcLANInterfaceAlertCommunityName Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.13 Description Defines the SNMP community used for BMC LAN alerts (traps) sent on the BMC LAN interface. Syntax DisplayString (SIZE (0..32)) Access Read-only Baseboard Management Controller Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 1351.
modemTerminal(4) Modem Terminal mode is enabled. directBasic(8) Direct Basic mode is enabled. directPPP(16) Direct PPP mode is enabled. directTerminal(32) Direct Terminal mode is enabled. Table 1353. BMC Serial Flow Control Type Variable Name:DellBMCSerialFlowControlType Data Type:Integer Possible Data Values Meaning of Data Value -- none(0) No flow control used. rtscts(1) RTS/CTS (hardware) flow control used. xonXoff(2) XON/XOFF flow control used. Table 1354.
Possible Data Values Meaning of Data Value -- legacyBMC(0) Controller type is legacy Baseboard Management Controller. iDRAC(8) Controller type is iDRAC. iDRAC6(10) Controller type is Integrated Dell Remote Access Controller 6. iDRAC6Modular(11) Controller type is Integrated Dell Remote Access Controller 6 (Modular). iDRAC6BMC(13) Controller type is Integrated Dell Remote Access Controller 6 (BMC mode). iDRAC7(16) Controller type is Integrated Dell Remote Access Controller 7.
Field Replaceable Unit Group A field replaceable unit (FRU) is a part that can be removed and replaced without having to send the system to a repair facility. The Field Replaceable Unit Group provides information about the field replaceable units that may be present in your system. Field Replaceable Unit Group Tables The objects in the FRU group define information such as manufacturer, serial number, part number and revision for field replaceable units. The following MIB tables define the FRU group.
Access Read-only Table 1362. FRU Information Status Name fruInformationStatus Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.3 Description Defines the status of the FRU table entry. Syntax DellStatus Access Read-only Table 1363. FRU Information State Name fruInformationState Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.4 Description Defines the state of the FRU information. Some information for the FRU may not be available if the state is other than ok(1).
Table 1367. FRU Part Number Name Name fruPartNumberName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.8 Description Defines the part number of the FRU Syntax DisplayString (SIZE (0..64)) Access Read-only Table 1368. FRU Revision Name Name fruRevisionName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.9 Description Defines the revision of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only Table 1369. FRU Manufacturing Date Name Name fruManufacturingDateName Object ID 1.3.6.1.4.1.
notAvailable(3) FRU information is not available. checksumInvalid(4) FRU information checksum is invalid. corrupted(5) FRU information is corrupted.
3 Storage Management Group The Storage Management Group is composed of the following: • Storage Management Group—information about the software product and system status. • Storage Management Information Group—properties about the Simple Network Management Protocol (SNMP) agent. • Global Data Group—system status. • Physical Devices Group—physical devices managed by the software. • Logical Devices Group—logical devices managed by the software. • Storage Management Event Group—SNMP traps.
Description Identifies global health for the subsystem managed by the Storage Management software. This global status is customized for HP OpenView. Other applications should refer to the agentSystemGlobalStatus entry in the globalData object group. Possible values: 1: Critical 2: Warning 3: Normal 4: Unknown Syntax Integer Access Read-only Table 1374. Software Manufacturer Name softwareManufacturer Object ID 1.3.6.1.4.1.674.10893.1.20.
Table 1377. Display Name Name displayName Object ID 1.3.6.1.4.1.674.10893.1.20.100.1 Description Identifies the name of this management software for display purposes. Syntax DisplayString Access Read-only Table 1378. Description Name description Object ID 1.3.6.1.4.1.674.10893.1.20.100.2 Description Provides a short description of this management software. Syntax DisplayString Access Read-only Table 1379. Agent Vendor Name agentVendor Object ID 1.3.6.1.4.1.674.10893.1.20.100.
Access Read-only Table 1382. Agent Last Global Status Name agentLastGlobalStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.2 Description This entry is obsolete. Use the value agentLastGlobalSystemStatus. Syntax Integer Access Read-only Table 1383. Agent Time Stamp Name agentTimeStamp Object ID 1.3.6.1.4.1.674.10893.1.20.110.3 Description Identifies the last time that the agent values have been updated. Universal time in seconds since UTC 1/1/70.
Description Identifies the rate, given in seconds, at which the cached data for SNMP is refreshed. The default value is 300 seconds, or 5 minutes. Syntax Integer Access Read-only Table 1387. Agent Hostname Name agentHostname Object ID 1.3.6.1.4.1.674.10893.1.20.110.7 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Table 1388. Agent IP Address Name agentIPAddress Object ID 1.3.6.1.4.1.674.10893.1.20.110.
Description Identifies the version of the Storage Management MIB. Syntax DisplayString Access Read-only Table 1392. Agent Management Software URL Name Name agentManagementSoftwareURLName Object ID 1.3.6.1.4.1.674.10893.1.20.110.12 Description Identifies the Universal Resource Locator (URL) of the systems management software. Syntax DisplayString Access Read-only Table 1393. Agent Global System Status Name agentGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.
3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1395. Agent Smart Thermal Shutdown Name agentSmartThermalShutdown Object ID 1.3.6.1.4.1.674.10893.1.20.110.15 Description Indicates the status of smart thermal shutdown for PowerVault 220S and PowerVault 221S enclosures.
• EMM Table — describes available properties for each Enclosure Management Module (EMM) on the managed system. • EMM Connection Table — describes the connection between each EMM on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table. • Battery Table — describes available properties for each controller battery on the managed system.
Description Identifies the name of the controller in this subsystem as represented in Storage Management. Includes the controller type and instance. For example: PERC 3/QC 1. Syntax DisplayString Access Read-only Table 1400. Controller Vendor Name controllerVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.3 Description Identifies the controller's (re)seller's name. Syntax DisplayString Access Read-only Table 1401. Controller Type Name controllerType Object ID 1.3.6.1.4.1.674.10893.1.
4: Offline 6: Degraded Syntax Integer Access Read-only Table 1403. Controller Severity Name controllerSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.6 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Table 1404. Controller Rebuild Rate In Percent Name controllerRebuildRateInPercent Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Table 1407. Controller Cache Size in Bytes Name controllerCacheSizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.10 Description Identifies the controller's current amount of cache memory that is less than a megabyte. This combined with the controllerCacheSizeInMB is the total amount of memory. Syntax Integer Access Read-only Table 1408. Controller Physical Device Count Name controllerPhysicalDeviceCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Table 1412. Controller Memory Size in Megabytes Name controllerMemorySizeInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.15 Description Identifies the size of memory in megabytes on the controller. If this size is 0, it is less than a megabyte. This attribute is only supported on Adaptec controllers. Syntax Integer Access Read-only Table 1413. Controller Memory Size in Bytes Name controllerMemorySizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Access Read-only Table 1417. Controller C0 Port 0 Name Name controllerC0Port0Name Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.20 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Table 1418. Controller C0 Port 0 ID Name controllerC0Port0ID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.21 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Table 1422. Controller C0 Battery State Name controllerC0BatteryState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.25 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1423. Controller C1 Port 0 World Wide Name Name controllerC1Port0WWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.26 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Table 1427. Controller C1 Channel Name controllerC1Channel Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.30 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1428. Controller C1 Operating System Controller Name controllerC1OSController Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.31 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Table 1432. Controller C1 Port 1 World Wide Name Name controllerC1Port1WWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.35 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Table 1433. Controller Battery Charge Count Name controllerBatteryChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.36 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1436. Controller Nexus ID Name controllerNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.39 Description Durable unique ID for this controller. Syntax DisplayString Access Read-only Table 1437. Controller Alarm State Name controllerAlarmState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.40 Description Indicates state, or setting for the controller's alarm.
Table 1439. Controller PCI Slot Name controllerPCISlot Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.42 Description Indicates the PCI slot number or embedded number for controllers on the motherboard Syntax DisplayString Access Read-only Table 1440. Controller Cluster Mode Name controllerClusterMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.43 Description Identifies if the controller is in cluster mode.
Table 1443. Controller SCSI Initiator ID Name controllerSCSIInitiatorID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.46 Description The SCSI ID of the initiator. Syntax Integer Access Read-only Table 1444. Controller Channel Count Name controllerChannelCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.47 Description The number of channels on the controller. Syntax Integer Access Read-only Table 1445. Controller Reconstruct Rate Name controllerReconstructRate Object ID 1.3.6.1.4.1.
Table 1448. Controller Check Consistency Rate Name controllerCheckConsistencyRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.51 Description The rate for check consistency on the controller. Syntax Integer Access Read-only Table 1449. Controller Patrol Read Mode Name controllerPatrolReadMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.52 Description Identifies the patrol read mode.
Table 1452. Controller Storport Driver Version Name controllerStorportDriverVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.55 Description Provides current Windows OS storport driver version. Not applicable for Linux. Syntax Octet String Access Read-only Table 1453. Controller Minimum Required Storport Version Name controllerMinimumRequiredStorportVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.56 Description Provides minimum required storport driver version for Windows OS only.
Access Read-only Table 1457. Controller Spin Down Unconfigured Drives Name controllerSpinDownUnconfiguredDrives Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.60 Description Indicates controller capability to put unconfigured drives in power save mode. Value: 1 - Enabled, 0 - Disabled, 99 - Undetermined /Not applicable Syntax Integer Access Read-only Table 1458. Controller Spin Down Hot Spare Drives Name controllerSpinDownHotSpareDrives Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Table 1461. Controller CacheCade Name controllerCacheCade Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.64 Description Indicates if the controller is CacheCade capable or not. Value: 1 - Capable, 0 - Not Capable, 99 Undetermined Syntax Integer Access Read-only Table 1462. Controller Spin Down Configured Drives Name controllerSpinDownConfiguredDrives Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.65 Description Indicates controller capability to spin down configured physical disks.
Value: 1 .. 24, 9999 - Undetermined Syntax Integer Access Read-only Table 1466. Controller Preserved Cache Name controllerPreservedCache Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.69 Description Indicates if preserved cache is present on the controller. Values: 1- Yes 0 - No 99 - Not available / Not applicable Syntax Integer Access Read-only Table 1467. Controller PI Enable Name controllerPIEnable Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Syntax Integer Access Read-only Table 1470. Controller Instance Name controllerInstance Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.73 Description Shows the current instance of the controller for stash. Syntax Integer Access Read-only Table 1471. Controller Non-RAID Disk Cache Policy Name controllerNonRAIDdiskCachePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.74 Description Displays the current disk write cache policy for Non-RAID disks.
Table 1474. Channel Number Name channelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.1 Description Identifies the instance number of the channel entry. Syntax Integer Access Read-only Table 1475. Channel Name Name channelName Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.2 Description Identifies the name of the channel as represented in Storage Management. The name includes the word channel and the instance. For example: Channel 1. Syntax DisplayString Access Read-only Table 1476.
Access Read-only Table 1478. Channel Termination Name channelTermination Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.5 Description Identifies the type of SCSI termination on this channel. Termination is required for proper operation of this channel. Possible values: 1: Wide Termination (16 bit) 2: Narrow Termination (8 bit) 3: Not Terminated Syntax Integer Access Read-only Table 1479. Channel SCSI ID Name channelSCSIID Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.
Table 1481. Channel Component Status Name channelComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.8 Description The status of the channel itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1482. Channel Nexus ID Name channelNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.9 Description Durable unique ID for this channel.
3: Fibre Channel 4: Serial Storage Architecture (SSA) 6: Universal Serial Bus (USB) 7: SATA 8: SAS 9: PCIe Syntax Integer Access Read-only Enclosure Table The following tables describe theavailable properties for each enclosure on the managed system. The following object sets up the Enclosure Table. Table 1485. Enclosure Table Name enclosureTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.3 Description Defines the enclosure table.
Table 1488. Enclosure Name Name enclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.2 Description Identifies the enclosure's name as represented in Storage Management. Syntax DisplayString Access Read-only Table 1489. Enclosure Vendor Name enclosureVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.3 Description Identifies the enclosure's (re)seller's name. Syntax DisplayString Access Read-only Table 1490. Enclosure State Name enclosureState Object ID 1.3.6.1.4.1.674.10893.1.
Table 1492. Enclosure ID Name enclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.6 Description Represents unique id for an enclosure. Syntax DisplayString Access Read-only Table 1493. Enclosure Processor Version Name enclosureProcessorVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.7 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Table 1494. Enclosure Service Tag Name enclosureServiceTag Object ID 1.3.6.1.4.1.674.10893.1.20.
Table 1497. Enclosure Split Bus Part Number Name enclosureSplitBusPartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.11 Description Identifies the enclosure's split bus part number. Syntax DisplayString Access Read-only Table 1498. Enclosure Product ID Name enclosureProductID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.12 Description Identifies the enclosure's product identification. This also corresponds to the enclosure type. Syntax DisplayString Access Read-only Table 1499.
Table 1502. Enclosure Type Name enclosureType Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.16 Description Indicates the type of the enclosure. Possible values: 1: Internal 2: Dell PowerVault 200S (PowerVault 201S) 3: Dell PowerVault 210S (PowerVault 211S) 4: Dell PowerVault 220S (PowerVault 221S) 5: Dell PowerVault 660F 6: Dell PowerVault 224F 7: Dell PowerVault 660F/PowerVault 224F 8: Dell MD1000 9: Dell MD1120 Syntax DisplayString Access Read-only Table 1503.
Table 1505. Enclosure Channel Number Name enclosureChannelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.19 Description Identifies the channel number, or bus, to which the enclosure is connected. Syntax Integer Access Read-only Table 1506. Enclosure Alarm Name enclosureAlarm Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.20 Description Identifies the current status of the enclosure's alarm (PowerVault 220S and PowerVault 221S only.
Description Identifies the severity of the enclosure state. This is the combined status of the enclosure and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1510. Enclosure Component Status Name enclosureComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.24 Description The status of the enclosure itself without the propagation of any contained component status.
Table 1512. Enclosure FirmWare Version Name enclosureFirmwareVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.26 Description The firmware version of the enclosure. Syntax DisplayString Access Read-only Table 1513. Enclosure SCSI Rate Name enclosureSCSIRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.27 Description Actual SCSI rate in the enclosure. Syntax DisplayString Access Read-only Table 1514. Enclosure Part Number Name enclosurePartNumber Object ID 1.3.6.1.4.1.674.10893.1.
Table 1517. Enclosure Occupied Slot Count Name enclosureOccupiedSlotCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.31 Description Shows the number of physical disk slots occupied in a storage enclosure. NOTE: A value of 9999 indicates that the feature is not available. Syntax Integer Access Read-only Table 1518. Enclosure Total Slots Name enclosureTotalSlots Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
The following object sets up the Array Disk Table. Table 1521. Array Disk Table Name arrayDiskTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.4 Description Defines the array disk table. Syntax SEQUENCE OF ArrayDiskEntry Access Not accessible Table 1522. Array Disk Entry Name arrayDiskEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1 Description Defines the array disk table entry. Syntax ArrayDiskEntry Access Not accessible Index arrayDiskNumber Table 1523.
Access Read-only Table 1526. Array Disk State Name arrayDiskState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.4 Description Identifies the current state of the array disk. Possible states: 0: Unknown 1: Ready - Available for use, but no RAID configuration has been assigned. 2: Failed - Not operational. 3: Online - Operational. RAID configuration has been assigned. 4: Offline - The drive is not available to the RAID controller.
Table 1527. Array Disk Severity Name arrayDiskSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Table 1528. Array Disk Product ID Name arrayDiskProductID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.6 Description Identifies the model number of the array disk. Syntax DisplayString Access Read-only Table 1529.
Table 1532. Array Disk Channel Name arrayDiskChannel Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.10 Description Identifies the bus to which this array disk is connected. Syntax Integer Access Read-only Table 1533. Array Disk Length in Megabytes Name arrayDiskLengthInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.11 Description Identifies the size in megabytes of the array disk. If this size is 0, it is smaller than a megabyte. Syntax Integer Access Read-only Table 1534.
Access Read-only Table 1537. Array Disk Target ID Name arrayDiskTargetID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.15 Description Identifies the SCSI target ID which this array disk is assigned. Syntax Integer Access Read-only Table 1538. Array Disk LUN ID Name arrayDiskLunID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.16 Description Identifies the array disk's logical unit number. Syntax Integer Access Read-only Table 1539.
Syntax Integer Access Read-only Table 1542. Array Disk Free Space in Bytes Name arrayDiskFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.20 Description Identifies the size in bytes of the free space on the array disk that is smaller than a megabyte. This size plus the arrayDiskFreeSpaceInMB is the total amount of free space on the array disk. Syntax Integer Access Read-only Table 1543. Array Disk Bus Type Name arrayDiskBusType Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
4: Disk is a dedicated hot spare 5: Not a spare 99: Not applicable Syntax Integer Access Read-only Table 1545. Array Disk Roll-Up Status Name arrayDiskRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.23 Description Severity of the array disk state. This is the combined status of the array disk and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1546.
Table 1547. Array Disk Device Name Name arrayDiskDeviceName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.25 Description Identifies the operating system device name for this disk. Syntax DisplayString Access Read-only Table 1548. Array Disk Nexus ID Name arrayDiskNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.26 Description Indicates the durable unique ID for this array disk. Syntax DisplayString Access Read-only Table 1549.
Table 1552. Array Disk Capable Speed Name arrayDiskCapableSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.30 Description Indicates the maximum speed at which the drive is capable of negotiating in MPS (megabytes per second). Syntax Integer Access Read-only Table 1553. Array Disk Smart Alert Indication Name arrayDiskSmartAlertIndication Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.31 Description Indicates whether the disk has received a predictive failure.
Description Indicates the four-digit year in which this disk was manufactured. Syntax DisplayString Access Read-only Table 1557. Array Disk Media Type Name arrayDiskMediaType Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.35 Description The Media type of the array disk. Possible Values: 1:unknown 2:hdd 3:ssd Syntax INTEGER Access Read-only Table 1558. Array Disk Dell Certified Name arrayDiskDellCertified Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Table 1561. Array Disk Alta Revision Id Name arrayDiskAltaRevisionId Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.39 Description Provides revision ID for Alta interposer. Syntax Octet String Access Read-only Table 1562. Array Disk Encryption Capable Name arrayDiskEncryptionCapable Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.40 Description Indicates if physical disk is encryption capable. Value: 1 - Capable, 0 - Not Capable, 99 - Not Applicable Syntax Integer Access Read-only Table 1563.
Access Read-only Table 1566. Array Disk Model Number Name arrayDiskModelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.44 Description Provides PCIe SSD device model number. Syntax DisplayString Access Read-only Table 1567. Array Disk Life Remaining Name arrayDiskLifeRemaining Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.45 Description Provides PCIe SSD device life remaining in percentage. Value: 0..100, 999 - Undetermined/Not Applicable Syntax INTEGER Access Read-only Table 1568.
Access Read-only Table 1570. Array Disk Read Only Name arrayDiskReadOnly Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.48 Description Provides the read only attribute for PCIe SSD. Possible Values: Yes, No, Not Applicable Syntax DisplayString Access Read-only Table 1571. Array Disk Remaining Rated Write Endurance Name arrayDiskRemainingRatedWriteEndurance Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.49 Description Provides the remaining rated write endurance for SAS/SATA SSD device.
Syntax INTEGER Access Read-only Table 1574. Array Disk Max Link Width Name arrayDiskMaxLinkWidth Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.52 Description Provides the information regarding Max Link Width of array disk. Possible Values: 0–8 Syntax INTEGER Access Read-only Table 1575. Array Disk Negotiated Link Width Name arrayDiskNegotiatedLinkWidth Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.53 Description Provides the information regarding Negotiated Link Width of array disk.
Enabled - Disabled - Default Syntax DisplayString Access Read-only Table 1578. Array Disk ISE Capable Name arraydiskISECapable Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.56 Description A boolean value decepting if the disk is Instant Secure Erase Capable or not. Syntax INTEGER Access Read-only Array Disk Enclosure Connection Table This table describes the connections among array disks, their enclosure, and their associated controller.
Description Identifies the instance number of the array disk enclosure connection entry. Syntax Integer Access Read-only Table 1582. Array Disk Enclosure Connection Array Disk Name Name arrayDiskEnclosureConnectionArrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.2 Description Identifies the name of the array disk in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Table 1583.
Description Identifies the name of the controller as represented in Storage Management to which this array disk is connected. Syntax DisplayString Access Read-only Table 1587. Array Disk Enclosure Connection Controller Number Name arrayDiskEnclosureConnectionControllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.7 Description Identifies the instance number in the controller, table of the controller to which this array disk is connected.
NOTE: Only array disks that are NOT part of an enclosure are listed in this table. Backplanes are considered enclosures by Storage Management. The following object sets up the Array Disk Channel Connection Table. Table 1588. Array Disk Channel Connection Table Name arrayDiskChannelConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.6 Description Defines the array disk channel connection table. Syntax SEQUENCE OF ArrayDiskChannelConnectionEntry Access Not accessible Table 1589.
Fan Table This table describes available properties for each fan on the managed system. The following object sets up the Fan Table. Table 1597. Fan Table Name fanTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.7 Description Defines the fan table. Syntax SEQUENCE OF FanEntry Access Not accessible Table 1598. Fan Entry Name fanEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1 Description Defines the fan table entry. Syntax FanEntry Access Not accessible Index fanNumber Table 1599.
Table 1601. Fan Vendor Name fanVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.3 Description Identifies the fan's (re)seller's name. Syntax DisplayString Access Read-only Table 1602. Fan State Name fanState Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.4 Description Identifies the current state of the fan. Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded 21: Missing Syntax Integer Access Read-only Table 1603. Fan Severity Name fanSeverity Object ID 1.
Access Read-only Table 1605. Fan Probe Minimum Warning Name fanProbeMinimumWarning Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.7 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Table 1606. Fan Probe Minimum Critical Name fanProbeMinimumCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.8 Description This entry is obsolete.
Description Identifies the current speed of the fan. Syntax DisplayString Access Read-only Table 1610. Fan1 Part Number Name fan1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.12 Description Identifies the part number of the fan in the enclosure. Syntax DisplayString Access Read-only Table 1611. Fan 2 Part Number Name fan2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.13 Description This entry is obsolete.
Description The status of the fan itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1614. Fan Nexus ID Name fanNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.16 Description Durable unique ID for this fan. Syntax DisplayString Access Read-only Table 1615. Fan Revision Name fanRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.
Access Not accessible Table 1617. Fan Connection Entry Name fanConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1 Description Defines the fan connection table entry. Syntax FanConnectionEntry Access Not accessible Index fanConnectionNumber Table 1618. Fan Connection Number Name fanConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.1 Description Identifies the instance number of the fan connection entry. Syntax Integer Access Read-only Table 1619.
Syntax DisplayString Access Read-only Table 1622. Fan Connection Enclosure Number Name fanConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.5 Description Identifies the instance number of the enclosure in the enclosureTable to which this fan belongs. Syntax Integer Access Read-only Power Supply Table This table describes available properties for each power supply on the managed system. The following object sets up the Power Supply Table. Table 1623.
Table 1626. Power Supply Name Name powerSupplyName Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.2 Description Identifies the power supply's name as represented in Storage Management. Syntax DisplayString Access Read-only Table 1627. Power Supply Vendor Name powerSupplyVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.3 Description Identifies the power supply's (re)seller's name. Syntax DisplayString Access Read-only Table 1628. Power Supply State Name powerSupplyState Object ID 1.3.
Table 1630. Power Supply 1 Part Number Name powerSupply1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.6 Description Identifies the part number of the power supply of the enclosure. Syntax DisplayString Access Read-only Table 1631. Power Supply 2 Part Number Name powerSupply2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.7 Description This entry is obsolete.
1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1634. Power Supply NexusID Name powerSupplyNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.10 Description Durable unique ID for this power supply. Syntax DisplayString Access Read-only Table 1635. Power Supply Revision Name powerSupplyRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.11 Description Indicates the revision number of the power supply in the enclosure.
Table 1637. Power Supply Connection Entry Name powerSupplyConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1 Description Defines the power supply connection table entry. Syntax PowerSupplyConnectionEntry Access Not accessible Index powerSupplyConnectionNumber Table 1638. Power Supply Connection Number Name powerSupplyConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.1 Description Identifies the instance number of the power supply connection entry.
Access Read-only Table 1642. Power Supply Connection Enclosure Number Name powerSupplyConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.5 Description Identifies the instance number of the enclosure in the enclosureTable to which this power supply belongs. Syntax Integer Access Read-only Table 1643. Power Supply Connection Firmware Version Name powerSupplyConnectionFirmwareVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.
Table 1645. Temperature Probe Entry Name temperatureProbeEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1 Description An entry in the Temperature Probe Table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. Syntax TemperatureProbeEntry Access Not accessible Index TemperatureProbeNumber Table 1646. Temperature Probe Number Name temperatureProbeNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.
1: Ready 2: Failed (Minimum Failure Threshold Exceeded, Maximum Failure Threshold Exceeded) 4: Offline 6: Degraded (Minimum Warning Threshold Exceeded, Maximum Warning Threshold Exceeded) 9: Inactive 21: Missing Syntax Integer Access Read-only Table 1650. Temperature Probe Severity Name temperatureProbeSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device.
Access Read-only Table 1654. Temperature Probe Maximum Warning Name temperatureProbeMaxWarning Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.9 Description Identifies the maximum temperature that forces the probe into a warning state. Syntax Integer Access Read-only Table 1655. Temperature Probe Maximum Critical Name temperatureProbeMaxCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.10 Description Identifies the maximum temperature that forces the probe into an error state.
Access Read-only Table 1658. Temperature Probe Component Status Name temperatureProbeComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.13 Description The status of the temperature probe itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1659. Temperature Probe Nexus ID Name temperatureProbeNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.
Table 1661. Temperature Probe Connection Entry Name temperatureConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1 Description Defines the temperature probe connection table entry. Syntax TemperatureConnectionEntry Access Not accessible Index temperatureConnectionNumber Table 1662. Temperature Probe Connection Number Name temperatureConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.1 Description Identifies the instance number of the temperature probe connection entry.
Access Read-only Table 1666. Temperature Probe Connection Enclosure Number Name temperatureConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.5 Description Identifies the instance number of the enclosure in the enclosureTable to which this temperature probe belongs. Syntax Integer Access Read-only Enclosure Management Module Table This table describes available properties for each enclosure management module on the managed system.
Table 1670. Enclosure Management Module Name Name enclosureManagementModuleName Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.2 Description Identifies the enclosure management module's name as represented in Storage Management. Syntax DisplayString Access Read-only Table 1671. Enclosure Management Module Vendor Name enclosureManagementModuleVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.3 Description Identifies the enclosure management module's (re)seller's name.
Syntax Integer Access Read-only Table 1674. Enclosure Management Module Part Number Name enclosureManagementModulePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.6 Description Identifies the part number of the enclosure memory module. Syntax Display String Access Read-only Table 1675. Enclosure Management Module Type Name enclosureManagementModuleType Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.7 Description Identifies the type of the enclosure management module.
Table 1678. Enclosure Management Module Roll-Up Status Name enclosureManagementModuleRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.10 Description Severity of the enclosure management module state. This is the combined status of the EMM and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1679.
Access Read-only Table 1681. Enclosure Management Module Revision Name enclosureManagementModuleRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.13 Description Identifies the revision number of the enclosure management module. Syntax DisplayString Access Read-only Enclosure Management Module Connection Table This table describes the connection between each enclosure management module on the managed system and its enclosure.
Table 1685. Enclosure Management Module Connection EMM Name Name enclosureManagementModuleConnectionEMMName Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.2 Description Identifies the name of the enclosure memory module in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Table 1686. Enclosure Management Module Connection EMM Number Name enclosureManagementModuleConnectionEMMNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.
Table 1689. Battery Table Name batteryTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.15 Description Defines the battery table. Syntax SEQUENCE OF BatteryEntry Access Not accessible Table 1690. Battery Entry Name batteryEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1 Description Defines the battery table entry. Syntax BatteryEntry Access Not accessible Index batteryNumber Table 1691. Battery Number Name batteryNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.
Table 1694. Battery State Name batteryState Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.4 Description Identifies the current state of battery. Possible values: 0: Unknown 1: OK 2: Failed 6: Degraded 7: Reconditioning 9: High 10: Low 12: Charging 21: Missing 36: Learning Syntax Integer Access Read-only Table 1695. Battery Roll-Up Status Name batteryRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.5 Description Severity of the battery state.
Table 1696. Battery Component Status Name batteryComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.6 Description The status of the battery itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1697. Battery Charge Count Name batteryChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.
Table 1700. Battery Predicted Capacity Name batteryPredictedCapacity Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.10 Description Displays the battery's ability to be charged. Possible values: 1: Failed - The battery cannot be charged and needs to be replaced. 2: Ready - The battery can be charged to full capacity. 4: Unknown - The battery is completing a Learn cycle. The charge capacity of the battery cannot be determined until the Learn cycle is complete.
Table 1703. Battery ID Name batteryID Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.13 Description Represents unique id for battery. Syntax Integer Access Read-only Table 1704. Battery Maximum Learn Delay Name batteryMaxLearnDelay Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.14 Description The maximum amount of time (in hours) that the battery learn cycle can be delayed. Syntax Integer Access Read-only Table 1705. Battery Learn Mode Name batteryLearnMode Object ID 1.3.6.1.4.1.674.
Syntax SEQUENCE OF BatteryConnectionEntry Access Not accessible Table 1707. Battery Connection Entry Name batteryConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1 Description Defines the battery connection table entry. Syntax BatteryConnectionEntry Access BatteryConnectionEntry Index BatteryConnectionNumber Table 1708. Battery Connection Number Name batteryConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.
Description Identifies the name of the controller as represented in Storage Management to which this battery belongs. Syntax DisplayString Access Read-only Table 1712. Battery Connection Controller Number Name batteryConnectionControllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.5 Description Identifies instance number of the controller in the controller table to which this battery belongs.
Description Instance number of this tape drive entry. Syntax INTEGER Access Read-only Table 1716. Tape Drive Name Name tapeDriveName Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.2 Description The name of the tape drive as represented in Storage Management. Syntax DisplayString Access Read-only Table 1717. Tape Drive Vendor Name tapeDriveVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.3 Description The tape drive's manufacturer's name.
Possible values: 8. SAS Syntax INTEGER Access Read-only Table 1721. Tape Drive SAS Address Name tapeDriveSASAddress Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.7 Description The specified SAS address if this is a SAS tape drive. Syntax DisplayString Access Read-only Table 1722. Tape Drive Media Type Name tapeDriveMediaType Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.8 Description The Media type of the tape drive.
Description An entry in the NvmeAdapter table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. Syntax NvmeAdapterEntry Access Not accessible Table 1725. NVME Adapter Number Name nvmeAdapterNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.1 Description Instance number of this NVME Adapter entry. Syntax INTEGER Access Read-only Table 1726. NVME Adapter State Name nvmeAdapterState Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.
Description The device name of the NVMe Adapter as it is represented in OMSA and also the operating system. Syntax DisplayString Access Read-only Table 1730. NVME Adapter Vendor Name nvmeAdapterVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.6 Description NVMe Adapter manufacturer. Syntax DisplayString Access Read-only Table 1731. NVME Adapter Product ID Name nvmeAdapterProductID Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.
Description NVMe Adapter driver version. Syntax DisplayString Access Read-only Table 1735. NVME Adapter PCI Bus Number Name nvmeAdapterPCIBusNo Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.11 Description The PCI Bus number of the NVMe adapter. Syntax INTEGER Access Read-only Table 1736. NVME Adapter PCI Device Number Name nvmeAdapterPCIDeviceNum Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.12 Description The PCI device number of the NVMe Adapter.
value: 9 (PCIeSSD) Syntax INTEGER Access Read-only Table 1740. NVME Adapter Media Type Name nvmeAdapterMediaType Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.16 Description NVMe Adapter media type. Possible Values: 1: unknown 2: ssd Syntax INTEGER Access Read-only Table 1741. NVME Adapter Length In Mega Bytes Name nvmeAdapterLengthInMegaBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.17 Description Size in megabytes of the NVMe Adapter.
Table 1744. NVME Adapter Model Number Name nvmeAdapterModelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.20 Description Model number of the NVMe Adapter as per the manufacturer. Syntax DisplayString Access Read-only Table 1745. NVME Adapter Negotiated Speed Name nvmeAdapterNegotiatedSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.21 Description The negotiated speed of the NVMe adapter in GT/s. Syntax DisplayString Access Read-only Table 1746.
Access Read-only Table 1749. NVME Adapter Supported Specification Name nvmeAdapterSupportedSpec Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.25 Description The NVMe specification supported by the device. Syntax DisplayString Access Read-only Table 1750. NVME Adapter Maximum Link Width Name nvmeAdapterMaxLinkWidth Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.26 Description The maximum bus width of NVME Adapter. Syntax INTEGER Access Read-only Table 1751.
Logical Devices Group The Logical Devices Management Information Base (MIB) group provides information about the logical devices managed by the Dell Storage Management Software and their relationships to each other.This group and all of its associated tables and objects are not supported on Microsoft Windows Advanced Server Limited Edition 64-bit operating system (Windows.Net-64) on a Dell PowerEdge 7150.
Table 1757. Virtual Disk Name Name virtualDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.2 Description Identifies the virtual disk's label generated by Storage Management or entered by the user. Syntax DisplayString Access Read-only Table 1758. Virtual Device Disk Name Name virtualDiskDeviceName Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.3 Description Identifies the device name used by this virtual disk's member disks. Syntax DisplayString Access Read-only Table 1759.
52: Permanently Degraded 54: Degraded Redundancy Syntax INTEGER Access Read-only Table 1760. Virtual Disk Severity Name virtualDiskSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax INTEGER Access Read-only Table 1761. Virtual Disk Length in Megabytes Name virtualDiskLengthInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
Table 1764. Virtual Disk Free Space in Bytes Name virtualDiskFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.9 Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax INTEGER Access Read-only Table 1765. Virtual Disk Write Policy Name virtualDiskWritePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.10 Description Indicates whether the controller's write cache are used when writing to a virtual disk.
Access Read-only Table 1767. Virtual Disk Cache Policy Name virtualDiskCachePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.12 Description Indicates whether the controller's cache is used when reading from or writing to a virtual disk. Possible values: 1: Direct I/O (LSI) 2: Cached I/O (LSI) 99: Not Applicable Syntax INTEGER Access Read-only Table 1768. Virtual Disk Layout Name virtualDiskLayout Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax INTEGER Access Read-only Table 1772. Virtual Disk Target ID Name virtualDiskTargetID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.17 Description Unique ID for the virtual disk. Syntax INTEGER Access Read-only Table 1773. Virtual Disk LUN ID Name virtualDiskLunID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.18 Description This entry is obsolete.
Table 1775. Virtual Disk Component Status Name virtualDiskComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.20 Description The status of the virtual disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1776. Virtual Disk Nexus ID Name virtualDiskNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
Table 1778. Virtual Disk Bad Blocks Detected Name virtualDiskBadBlocksDetected Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.23 Description Indicates if virtual disk has bad blocks. Value: 0 - No, 1 - Yes, 2 - Not Applicable, 99 - Unknown Syntax INTEGER Access Read-only Table 1779. Virtual Disk Encrypted Name virtualDiskEncrypted Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.24 Description Indicates if virtual disk is encrypted.
Table 1782. Virtual Disk PI Enable Name virtualDiskPIEnable Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.28 Description Indicates if T10 PI is enabled on a virtual disk. Possible values are: 0 : T10 PI disabled, 1 : T10 PI enabled Syntax INTEGER Access Read-only Virtual Disk Partition Table 1783. Virtual Disk Partition Table Name virtualDiskPartitionTable Object ID 1.3.6.1.4.1.674.10893.1.20.140.2 Description A table of managed virtual disk partitions.
Table 1786. Virtual Disk Partition Device Name Name virtualDiskPartitionDeviceName Object ID 1.3.6.1.4.1.674.10893.1.20.140.2.1.2 Description Device name of the partition given by the operating system. Syntax OCTET STRING Access Read-only Table 1787. Virtual Disk Partition State Name virtualDiskPartitionState Object ID 1.3.6.1.4.1.674.10893.1.20.140.2.1.3 Description State of the partition. This is mapped stated of the associate virtual disk.
Table 1790. Array Disk Logical Connection Table Name arrayDiskLogicalConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.140.3 Description Defines the array disk logical connection table. Syntax SEQUENCE OF arrayDiskLogicalConnectionEntry Access Not accessible Table 1791. Array Disk Logical Connection Entry Name arrayDiskLogicalConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1 Description Defines the array disk logical connection table entry.
Table 1795. Array Disk Logical Connection Virtual Disk Name Name arrayDiskLogicalConnectionVirtualDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.4 Description Identifies the name of the virtual disk to which this array disk belongs. Syntax DisplayString Access Read-only Table 1796. Array Disk Logical Connection Virtual Disk Number Name arrayDiskLogicalConnectionVirtualDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.
Syntax Integer Access Read-only Table 1800. Description Event Name descriptionEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.2 Description Storage Management event message text describing the alert. Syntax DisplayString Access Read-only Table 1801. Location Event Name locationEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.3 Description Additional information identifying the location of the object causing the alert. Syntax DisplayString Access Read-only Table 1802.
Access Read-only Table 1805. Current Status Event Name currentStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.7 Description Status of object causing the alert, if applicable. Syntax DellStatus Access Read-only Table 1806. Previous Status Event Name previousStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.8 Description Previous status of object causing the alert if applicable. Syntax DellStatus Access Read-only Table 1807.
Table 1810. Chassis Service Tag Event Name chassisServiceTagEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.12 Description Chassis Service Tag of object causing the alert if applicable.
4 Change Management Group The Change Management Group lets you monitor information about the devices and software that are present on a particular managed computer chassis. This information is collected during an inventory scan. NOTE: On systems running Linux, the optional srvadmin-cm RPM package must be installed for Dell EMC OpenManage Server Administrator to respond to SNMP queries in this group. See the Dell EMC Server Administrator Installation Guide for more information.
Syntax SystemID Access Read-only Device Group The Device Group defines information about the devices discovered on the system during an inventory scan. Identifying information includes the Component ID, the Device ID, and the Vendor ID. Device Group Table The following object sets up the Device Group Table. Table 1814. Device Table Name deviceTable Object ID 1.3.6.1.4.1.674.10899.1.5 Description Defines the Device Table. Syntax SEQUENCE OF DeviceEntry Access Not accessible Table 1815.
Table 1818. Device Display String Name deviceDisplayString Object ID 1.3.6.1.4.1.674.10899.1.5.1.3 Description Provides a displayable string that describes the device. Syntax DisplayString Access Read-only Table 1819. Device Vendor ID Name deviceVendorID Object ID 1.3.6.1.4.1.674.10899.1.5.1.4 Description Defines the ID for the vendor supplying the device. Syntax Octet String Access Read-only Table 1820. Device ID Name deviceDeviceID Object ID 1.3.6.1.4.1.674.10899.1.5.1.
Application Group NOTE: Dell updateable components such as Basic input/output system (BIOS) and Firmware (FW) are considered applications. For example, the following would be returned for system BIOS: Application/DisplayString = BIOS Application/ Version = A10 The Application Group defines information about the applications discovered on the system during an inventory scan. Identifying information includes the application type, the application version, and the application description.
Table 1827. Application Component Type Name applicationComponentType Object ID 1.3.6.1.4.1.674.10899.1.6.1.3 Description Identifies the type of application reported. Syntax DisplayString Access Read-only Table 1828. Application Version Name applicationVersion Object ID 1.3.6.1.4.1.674.10899.1.6.1.4 Description Identifies the version of the application. Syntax DisplayString Access Read-only Table 1829. Application Display String Name aplicationDisplayString Object ID 1.3.6.1.4.1.674.
5 SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures. Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion.
Table 1831. Trap Variables Variable Name alertSystem Object ID 1.3.6.1.4.1.674.10892.1.5000.10.1 Description Identifies the system generating the alert. Syntax DisplayString Table 1832. Table Index OID Variable Name alertTableIndexOID Object ID 1.3.6.1.4.1.674.10892.1.5000.10.2 Description Specifies the object identifier for the index attribute in the table that contains the object causing the alert.
Syntax Octet String The following variables show the Enhanced varbinds: Table 1837. Message ID Variable Name alertMsgID Object ID 1.3.6.1.4.1.674.10892.4.5000.10.7 Description Specifies the enhanced message ID for the object generating the alert. Syntax DisplayString Table 1838. System FQDN Variable Name alertSystemFQDN Object ID 1.3.6.1.4.1.674.10892.4.5000.10.8 Description Specifies fully qualified domain name of the system generating the alert. Syntax DisplayString Table 1839.
Description Line Item Explanation Additional details: Specifies possible additional details about the specified device, for example: Additional details: Memory device: DIMM_1A Serial number: 11111111 Memory device: DIMM_1B Serial number: 22222222 Specifies any additional power supply information pertaining to the event, for example: Power supply input AC is off, Power supply POK (power OK) signal is not normal, Power suppl
Description Line Item Explanation Log type: Embedded Server Management (ESM) Memory device bank location: Specifies the name of the memory bank in the system that generated the message, for example: Memory device bank location: Bank_1 Memory device location: Specifies the location of the memory module in the chassis, for example: Memory device location: DIMM_A Number of devices required for full redundancy: Specifies the number of power supply
Description Line Item Explanation Temperature sensor value (in degrees Celsius): Specifies the temperature in degrees Celsius, for example: Temperature sensor value (in degrees Celsius): 30 Voltage sensor value (in Volts): Specifies the voltage sensor value in volts, for example: Voltage sensor value: 1.693 Understanding Trap Severity Traps often contain information about values recorded by probes or sensors.
TrapID Description Severity 65801 Over-Temperature Problem (Upper Critical going high) Critical 65929 Over-Temperature Problem Cleared Information 131328 Under-Voltage Warning (Lower Non Critical - going low) Warning 131456 Under-Voltage Warning Cleared Information 131330 Under-Voltage Problem (Lower Critical going low) Critical 131458 Under-Voltage Problem Cleared Information 131335 Over-Voltage Warning (Upper Non Critical going high) Warning 131463 Over-Voltage Warning Cleared In
TrapID Description Severity 487173 CPU Configuration Error Critical 487301 CPU Configuration Error Cleared Information 487175 CPU Presence (Processor Presence detected) Information 487303 CPU Not Present (Processor Not Present) Critical 487170 CPU BIST (Built In Self Test) Failure Critical 487298 CPU BIST (Built In Self Test) Failure Cleared Information 487176 CPU Disabled (Processor Disabled) Critical 487304 CPU Enabled (Processor Enabled) Information 487178 CPU Throttle (Process
6 Storage Management Alert Reference Storage Management’s alert or event management features let you monitor the health of storage resources such as controllers, connectors, array disks, and virtual disks. Topics: • Alert Monitoring and Logging • Viewing Alerts • Alert Severity Levels • SNMP Support for Storage Management Alerts • Viewing SNMP Traps • Alert Descriptions and Corrective Actions Alert Monitoring and Logging The Storage Management Service performs alert monitoring and logging.
Table 1843. Storage Management Alert Severity Alert Severity Component Status OK/Normal/Informational No action is required. The alert is provided for informational purposes and does not indicate an error condition. For example, the alert may indicate the normal start or stop of an operation. Warning/Non-critical A component requires attention. This alert indicates a potential problem, but does not necessarily mean that the system has currently lost data or is nonfunctional.
Trap Variables The Storage Management SNMP traps use a set of variables that are included with every trap. Below mentioned variables are the Traditional Varbinds: Table 1844. Message ID Event Name messageIDEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.1 Description Storage Management alert (event) message number. Syntax INTEGER Access Read-only Table 1845. Description Event Name descriptionEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.
Description MIB OID of the object causing the alert. Syntax DisplayString Access Read-only Table 1849. Object Nexus Event Name objectNexusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.6 Description Durable, unique ID of the object causing the alert. Syntax DisplayString Access Read-only Table 1850. Current Status Event Name currentStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.7 Description Status of object causing the alert, if applicable.
Table 1853. Enhanced System FQDN Event Name systemFQDNEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.10 Description Hostname of object causing the alert if applicable. Syntax DisplayString Access Read-only Table 1854. Enhanced Service Tag Event Name serviceTagEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.11 Description Service Tag of object causing the alert if applicable. Syntax DisplayString Access Read-only Table 1855.
7 Standard Data Type Definitions This appendix contains definitions for data types that are standard in most contexts across the information technology industry. These are the most common data types for describing variable values defined in the 10892.mib , dcs3rmt.mib and dcs3fru.mib files. Server Administrator-specific variable values are defined in the last section of the section in which they are introduced.
Table 1857. Dell State Capabilities Variable Name: DellStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value if set to zero(0) The object has no capabilities. unknownCapabilities(1) The object’s capabilities are unknown. enableCapable(2) The object can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The object is not ready. enableAndNotReadyCapable (6) Enable and not ready capable. Table 1858.
Possible Data Values Meaning of Data Value other(1) The object’s status is not one of the following: unknown(2) The object’s status is unknown. ok(3) The object’s status is OK. nonCritical(4) The object’s status is warning, noncritical. critical(5) The object’s status is critical (failure). nonRecoverable(6) The object’s status is nonrecoverable (dead). absent(7) The object’s status is absent Table 1861.
Data Type: DellUnsigned64BitRange Octet String (SIZE(8)) The DellDate definition is required because SNMP V1 does not support 64-bit ranges. The information sent back by this subagent has the most significant byte of the information as the first byte. For example, the hex address 0x1029384754657687 is sent as hex: 0001 0000 0010 1001 0011 1000 0100 0111 ... Byte 1 Byte 2 Byte 3 Byte 4.
8 SNMP Sample Output This appendix contains the sample output from the Simple Network Management Protocol (SNMP) covering the first four groups of the Instrumentation management information base (MIB) sample output from the Simple Network Management Protocol (SNMP) covers the first four groups of the Instrumentation management information base (MIB).
1.3.6.1.4.1.674.10892.1.200.10.1.26.1 = '\02\02\02\02' 1.3.6.1.4.1.674.10892.1.200.10.1.27.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.28.1 = '\03\03\03\03' 1.3.6.1.4.1.674.10892.1.200.10.1.29.1 = '\02' 1.3.6.1.4.1.674.10892.1.200.10.1.30.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.31.1 = '\03' 1.3.6.1.4.1.674.10892.1.200.10.1.41.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.42.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.43.1 = '\03' 1.3.6.1.4.1.674.10892.1.300.10.1.1.1 = 1 1.3.6.1.4.1.674.10892.1.300.10.1.2.1 = 0 1.3.6.1.4.1.
1.3.6.1.4.1.674.10892.1.300.40.1.8.1.1 = '20050513100047.