CLI Guide
Event Name Description
event=enclosurefail Sets actions when an enclosure detects a failure value.
event=storagectrlbatterywarn
Sets actions when a storage controller battery detects a warning value.
NOTE: This event is not available on blade systems.
event=storagectrlbatteryfail
Sets actions when a storage controller battery detects a failure value.
NOTE: This event is not available on blade systems.
Example Set Alert Action Commands
The following are examples of valid example commands. For each successful command issued, the following message is displayed:
Alert action(s) configured successfully.
Example Current Probe Actions
To disable system console alert if a current probe detects a warning event, type:
omconfig system alertaction event=currentwarn alert=false
or
omconfig servermodule alertaction event=currentwarn alert=false
To enable broadcast messages if a current probe detects a failure event, type:
omconfig system alertaction event=currentfail broadcast=true
or
omconfig servermodule alertaction event=currentfail broadcast=true
Example Fan Probe Actions
To generate alerts when a fan probe detects a failure value, type:
omconfig system alertaction event=fanfail alert=true
or
omconfig servermodule alertaction event=fanfail alert=true
Example chassis intrusion actions
To clear all alert actions for chassis intrusion, type:
omconfig system alertaction event=intrusion clearall=true
or
omconfig servermodule alertaction event=intrusion clearall=true
Omcong
Managing Components Using The Instrumentation Service 113