Reference Guide
Table Of Contents
- Dell EMC OpenManage Version Port Information Guide Version 9.1
- Introduction
- Ports
- OpenManage Essentials
- Dell Chassis Management Controller
- OpenManage Integration for VMware vCenter
- OpenManage Server Administrator
- OpenManage Storage Management
- Dell Command Monitor OpenManage Client Instrumentation
- OpenManage Baseboard Management Utility
- Dell Management Console
- OpenManage Power Center
- Dell Lifecycle Controller Integration for System Center Configuration Manager
- Dell Lifecycle Controller Integration for System Center Virtualization Machine Manager
- Dell Connections License Manager DCLM
- Dell Management Pack for System Center Operation Manager
- Dell Smart Plug-in SPI for HP Operations Manager for Microsoft Windows
- OpenManage Connection for IBM Tivoli Network Manager
- OpenManage Connection for IBM Tivoli Netcool OMNIbus
- OpenManage Plug-in for Nagios
- iDRAC Service Module
- iDRAC7 and iDRAC8
- iDRAC6 for Rack and Tower Servers
- iDRAC for Blade Servers
- iDRAC6 Enterprise for Blade Servers
- Dell Remote Access Configuration Tool DRACT
- Digital KVM
- DRAC 5
- DRAC 4
Managed Node
Table 12. Supported Protocols and Ports on Managed Nodes
Port Number Protocol Port
Type
Maximum
Encryption Level
Direction Usage
22 SSH TCP 256–bit AES In/Out Non-Dell chassis communication
161 SNMP Agent UDP 56-bit DES In/Out SNMP query management
443 WSMAN TCP 256-bit AES In/Out Chassis communication
623 RMCP/RMCP+ UDP 128-bit AES In/Out IPMI access over LAN
Dell Lifecycle Controller Integration for System
Center Configuration Manager
Table 13. Management Station
Port
Number
Protocols Port Type Maximum
Encryption
Level
Direction Usage Configurabl
e
21 FTP TCP None Out FTP command client No
53/139 DNS TCP None Out DNS client for SCCM Console AD
login
No
443 WSMAN TCP 128-bit In/Out iDRAC/DLCI communication No
445 NetBIOS TCP None In/Out CIFS File Share No
2049 NFS UDP/TCP None All Public Share No
4433 HTTPS TCP 128-bit In Auto Discovery No
4434 HTTPS TCP None In/Out Non-Windows OSD No
NOTE: All other ports are as per SCCM. For more information, visit https://technet.microsoft.com/en-us/library/
hh427328.aspx
Table 14. Managed Node
Port
Number
Protocols Port Type Maximum
Encryption
Level
Direction Usage Configurabl
e
443 WSMAN TCP 128-bit In/Out iDRAC/DLCI communication No
445 NetBIOS TCP None In/Out CIFS File Share No
2049 NFS UDP/TCP None All Public Share No
4434 HTTPS TCP None In/Out Non-Windows OSD No
Ports 15