Users Guide
If the communication channel between the connector and the rst enclosure is lost, the redundant path conguration is lost. In this case,
the health of the logical connector is displayed as critical. Navigate to the
Information/Conguration page of the logical connector to view
details of the Path Health. For a brief outline of this scenario, see the following table:
Table 14. Path between Controller and Enclosure 1
Health of Logical Connector Path between Controller and Enclosure 1
Connector 0 (C0) Connector 1 (C1)
Available Available
Available Disconnected
Disconnected Available
However, if the communication channel between any two enclosures is lost, the redundant path conguration is degraded and the health of
the logical connector is displayed as degraded. For a brief outline of this scenario, see the following table.
Table 15. Path between Enclosure
n
and Enclosure
n
+1
Health of Logical Connector Path between Enclosure
n
and Enclosure
n
+1
Connector 0 (C0) Connector 1 (C1)
Available Available
Available Disconnected
Disconnected Available
In the above scenario, the enclosure status is displayed in warning mode. Clicking Information/Conguration in the Enclosures page
displays all enclosure components (EMMs, Fans, Physical Disks, Power Supplies, and Temperature) in normal condition. To view the Path
Controllers
73