Users Guide
Virtual Disk Specication PERC S100 PERC S110 PERC S130 PERC S300 PERC S140
Minimum Number of
Physical Disks in a RAID 1
2 2 2 2 2
Minimum Number of
Physical Disks in a RAID
5
3 3 3 3 3
Minimum Number of
Physical Disks in a RAID
10
4 4 4 4 4
NOTE: When creating virtual disks using software RAID controllers, the information related to the physical disks linked to the
virtual disk is enumerated or displayed on Storage Management after a short delay. This delay in displaying the information does
not cause any functional limitation. If you are creating partial virtual disks, it is recommended that you provide Storage
Management adequate time between each partial virtual disk creation process.
RAID Levels Supported By The PERC Software RAID
Controllers
Table 61. RAID Levels Supported by the PERC S100, PERC S110, PERC S130, PERC S300 and S140 Controllers
RAID Level PERC S100 PERC S110 PERC S130 PERC S300 PERC S140
RAID 0 Yes Yes Yes Yes Yes
RAID 1 Yes Yes Yes Yes Yes
RAID 5 Yes No Yes Yes Yes
RAID 10 Yes No Yes Yes Yes
RAID 50 No No No No No
RAID 6 No No No No No
RAID 60 No No No No No
Read Write Cache And Disk Cache Policy Supported By The
PERC Software RAID Controllers
Table 62. Read, Write, and Cache Policy Supported by the PERC S100, PERC S110, PERC S130, and S300 Controllers
Read, Write, and
Cache Policy
PERC S100 PERC S110 PERC S130 PERC S300
Cache settings Yes Yes Yes Yes
Read Policy Yes Yes Yes Yes
Read Ahead (Enabled) Yes Yes Yes Yes
No Read Ahead
(Disabled)
Yes Yes Yes Yes
208 Supported Features